SAFETY PRECAUTIONS

GREENSTAR UTILITY 32/50 - 50/70

8 716 109 712b (07.2010)

2

INTRODUC

TION

SAFETY PRECAUTIONS

OIL FUMES OR LEAKS FROM THE BOILER:

Extinguish any naked flames.

Open windows and doors.

Switch off the boiler electricity supply.

Isolate the fuel supply to the boiler.

Contact installer/service engineer.

IMPORTANT:

This boiler must only be operated by a responsible adult who has been instructed in, 
understands and is aware of the boiler’s operating conditions and effects. 

HEALTH & SAFETY:

The appliance contains no asbestos and no substances have been used in the construction

process that contravene the COSHH Regulations (Control of Substances Hazardous to Health

Regulations 1988). Where applicable, the CE mark indicates compliance with relative 

EU Directives.

COMBUSTIBLE AND CORROSIVE MATERIALS:

Do not

store or use any combustible materials (paper, thinners, paints etc.) inside or within the

vicinity of the boiler.

The combustion air must be kept clear of chemically aggressive substances which can corrode
the boiler and invalidate any warranty.

FITTING & MODIFICATIONS:

Fitting the boiler and any controls to the boiler may only be carried out by a competent
engineer in accordance with the relevant Installation Regulations.

Flue systems must not be modified in any way other than as described in the fitting instructions.

Any misuse or unauthorised modifications to the boiler, flue or associated components and
systems could invalidate the warranty. The manufacturer accepts no liability arising from any such
actions, excluding statutory rights.

This boiler is suitable for use with kerosene only, no other fuel may be used.

DO NOT OPERATE THE APPLIANCE WHEN:

The appliance, flue or system is incorrectly fitted, faulty or damaged.

The flue terminal outlet is obstructed or damaged.

There are fumes, fuel leaks or fuel smells from the fuel supply, appliance or internal flue system.

The system is empty, frozen or unpressurised (sealed systems).

The condensate pipe is blocked or restricted.

The appliance clearances are inadequate.

The air supply is restricted or vents damaged.

8 716 109 712b 07.10  12/7/10  12:28  Page 4

Содержание GREENSTAR UTILITY 32/50

Страница 1: ...ER CONVENTIONAL FLUE ROOM SEALED FLUE FOR FULLY PUMPED OPEN VENT OR SEALED CENTRAL HEATING SYSTEMS AND DOMESTIC HOT WATER CYLINDERS THE BOILER IS FOR USE WITH KEROSENE 28 SECOND OIL ONLY UK USER INSTR...

Страница 2: ...OR MODEL OF BOILER THE INSTRUCTIONS APPLY IN MAINLAND UK ONLY AND SHOULD BE FOLLOWED EXCEPT FOR ANY STATUTORY OBLIGATION IF YOU ARE IN ANY DOUBT CONTACT THE WORCESTER BOSCH GROUP TECHNICAL SUPPORT THI...

Страница 3: ...please leave this User Manual along with the Installation Commissioning and Servicing Instructions and completed Benchmark Checklist with the user DEDICATED TO HEATING COMFORT Thank you for purchasing...

Страница 4: ...of chemically aggressive substances which can corrode the boiler and invalidate any warranty FITTING MODIFICATIONS Fitting the boiler and any controls to the boiler may only be carried out by a compe...

Страница 5: ...rheat thermostat behind front panel C Reset button flue overheat thermostat behind front panel D Reset button lockout top of burner under top panel E Upper front panel pull squarely away from the boil...

Страница 6: ...F for heating and hot water If the boiler is left unused and exposed to freezing conditions shut off all the mains supplies isolate the boiler and drain the system and boiler SETTING TEMPERATURE Turn...

Страница 7: ...OTECTION Frost thermostats can be wired into the boiler Frost protection should be fitted to the system where the system is most exposed and at risk of freezing If there is no hot water or heating che...

Страница 8: ...of a service engineer Boiler overheat manual reset Should the boiler temperature rise beyond the automatic reset level a high limit thermostat will switch the boiler off indicated by button B standing...

Страница 9: ...re exceeded by large amount Temperature rises instead of falling Radiators are too hot Clock is incorrectly set Increase thermostatic radiator valve setting s Increase temperature control setting Blee...

Страница 10: ...please visit worcester bosch co uk Please tick the appropriate box on your warranty registration card for further details of the Worcester Bosch Group Service Contract When your boiler requires servic...

Страница 11: ...installation unless the installation conditions and usage demand more frequent services IMPORTANT Ensure that the service engineer completes the Service Record in the checklist after each service The...

Страница 12: ...ir supply must not be restricted or contaminated The boiler clearances must meet the minimum shown below for servicing and venting purposes If this clearance is less than 75mm the flue knock out panel...

Страница 13: ...ents as described in BS 5410 A minimum of two air vents must be fitted one at low level and another at high level onto the same wall using the same air for circulation Combustion air must not be taken...

Страница 14: ...oiler guarantee CONDENSATE DRAIN This is a condensing boiler and the terminal will at times give out a plume of water vapour This is quite normal The boiler also produces quantities of condensate whic...

Страница 15: ...ors in unused rooms spare bedrooms etc you may experience slightly lower room temperatures in rooms adjacent to unheated rooms Heating economically The boiler is designed to provide a high level of co...

Страница 16: ...ur Field Service Engineer finds no fault with the boiler see Note OR Evidence cannot be provided that the first year service inspection has been carried out i e an entry in the service interval record...

Страница 17: ...epair of this boiler by third parties will not be accepted for payment by Bosch Thermotechnology Ltd That the householder may be asked to prove when requested the date of installation that the boiler...

Страница 18: ...NOTES GREENSTAR UTILITY 32 50 50 70 8 716 109 712b 07 2010 16 NOTES NOTES 8 716 109 712b 07 10 12 7 10 12 28 Page 18...

Страница 19: ...17 NOTES NOTES GREENSTAR UTILITY 32 50 50 70 8 716 109 712b 07 2010 NOTES 8 716 109 712b 07 10 12 7 10 12 28 Page 19...

Страница 20: ...rand name of Bosch Thermotechnology Ltd 8 716 109 712b 07 2010 WORCESTER BOSCH GROUP TECHNICAL SUPPORT 0844 892 3366 APPOINTMENTS 0844 892 3000 SPARES 01905 752571 LITERATURE 0844 892 9800 TRAINING 01...

Отзывы: