SERVICING AND SPARES
Greenstar FS CDi
ErP
6720818079 (2016/04)
33
▶ Press at the bottom to remove the metal plate [3], if fitted.
Fig. 49 Remove metal plate
▶ Using the cleaning blade, working from the bottom to the top, to
loosen any deposits in the heat exchanger.
Fig. 50
▶ Using the brush, clean the heat exchanger from top to bottom.
Fig. 51
▶ Use the handle of the brush to remove debris from the condensate
tray.
▶ Place a suitable container under the sump condensate outlet to
collect any water and debris.
▶ Pour water into the top of the heat exchanger to flush out the debris.
Fig. 52
▶ Refit the cleaning access cover assembly in reverse order, the metal
plate [3] first, then the new seal [2], lastly the access cover [1].
▶ Refit the condensate trap.
▶ Pour 250ml of clean water into the heat exchanger to fill the
condensate trap.
6720818079-18.1Wo