General Information

Greenstar Danesmoor Utility 

ErP

 – 6 720 813 330 (2014/09)

Combustion air/room air

The air in the installation room must be free of combustible or 
chemically aggressive substances.

▶ Do not use or store combustible or explosive materials 

(paper, propellants, thinners, paints, etc.) within the 
vicinity of the appliance.

▶ Do not use or store corrosive substances (solvents, 

adhesives, chlorinated cleaning agents, etc.) within the 
vicinity of the appliance.

Appliance operation:

This appliance can be used by children aged from 8 years and 
above and persons with reduced physical, sensory or mental 
capabilities or lack of experience and knowledge, if they have 
been given supervision or instruction concerning the use of the 
appliance, in a safe way, and understand the hazards involved.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children 
without supervision.

Intended use

This appliance must only be used as a heat appliance in a sealed 
hot water heating system for domestic purposes.

Any misuse or unauthorised modifications to the appliance, 
flue or associated accessories and heating system will 
invalidate the guarantee.

Do not modify the appliance or flue system in any way.

Worcester, Bosch Group accepts no liability arising from any 
such actions. This does not affect your statutory rights.

2

General Information

2.1

Energy efficiency

Energy efficiency information is given in the Installation, 
Commissioning and Servicing Instructions supplied with the 
appliance.

2.2

Servicing

The Service Checklist can be found at the rear of the boiler’s 
installation instructions. It will be required in the event of any 
guarantee work and may be required by the local Building 
Control Inspector.

▶ Have the boiler serviced regularly by a competent, OFTEC 

registered engineer.

▶ Ensure that the service engineer completes the Service 

Record, at the rear of the Installation, Commissioning and 
Servicing Instruction manual, after each service. 

▶ Have any work carried out only by a competent, OFTEC 

registered engineer.

▶ Always use original spares, to help maintain the efficiency, 

safety and reliability of the appliance.

2.3

User caution

It is forbidden for any interference with the appliance other 
than those actions allowed in this document.

CAUTION: 

Incorrect use

▶ Any incorrect use can result in danger to 

the householder.

Содержание Greenstar Danesmoor Utility ErP 50/70

Страница 1: ...iler conventional flue and room sealed flue Greenstar Danesmoor Utility ErP 32 50 50 70 6 720 813 330 01 1TL For fully pumped open vent and sealed central heating systems and domestic hot water cylinders For use with Kerosene Class C2 only 6 720 813 330 2014 09 ...

Страница 2: ...icular is extremely energy efficient offeringyoueconomicalrunningcostsandvalueformoney Itis amongst the top energy rated appliances available Thereisalsothereassuranceofourpartsandlabourguarantee backed up by Worcester Total Cover an optional complete maintenance scheme to keep your appliance operating at peak condition and efficiency Contents 1 Key to symbols and safety instructions 3 1 1 Key to ...

Страница 3: ...er List entries first and second levels A single component item A component list made up of multiple parts items Sub component or sublist of main component list etc 1 2 Safety instructions These operating instructions are intended for the user of the heating system Read any operating instructions boiler heating controls etc carefully before operation and keep them Observe the safety instructions a...

Страница 4: ...o the appliance flue or associated accessories and heating system will invalidate the guarantee Do not modify the appliance or flue system in any way Worcester Bosch Group accepts no liability arising from any such actions This does not affect your statutory rights 2 General Information 2 1 Energy efficiency Energy efficiency information is given in the Installation Commissioning and Servicing Ins...

Страница 5: ...is set to ON Set the room thermostat to the desired setting Open and set thermostatic radiator valves as required Turn the boiler water temperature control to the required setting To switch off the boiler turn the programmer timer to OFF for heating and hot water If the boiler is left unused and exposed to freezing conditions shut off all the mains supplies isolate the boiler and drain the system ...

Страница 6: ... contact a Worcester BoschGroupcontactcentre seethebackcoverfor details In addition tothe service contract we are pleased to offer a one off annual service or breakdown call out for your boiler Maintenance tips Regularly check the oil level in the tank Do not obstruct the flue outlet or the air inlet Regularly check the system pressure gauge see chapter 4 Use in hard water areas In exceptionally h...

Страница 7: ...mbustion purposes through a permanent inlet such as an air brick into the area where the boiler is situated Ifacupboardorcompartmentwhichistobeusedforstorageor airing is built around the boiler after installation there must be a non combustible partition around the boiler Further information can be found in BS 5410 which also describes venting requirements Conventional flued boilers Minimum area o...

Страница 8: ...tral heating system check that all radiators are being heated at an even rate If the top of a radiator is at a lower temperature than the bottom then it should be vented by releasing air through the venting screw at the top of the radiator Ask your installer to show you how this is done Repeated venting will reduce the quantityofwaterinthesystemandthismustbereplenishedfor safe and satisfactory ope...

Страница 9: ... central heating flow on boiler set too low Increase central heating flow temperature control setting Low temperature setting on the room thermostat Increase settings on room thermostat Desired room temperature is too high Thermostatic radiator valve s are set too high Turn down thermostatic radiator valves room thermostat Room thermostat is set too high Reduce central heating temperature by turni...

Страница 10: ...en activated to prevent the boiler from operating Automatic reset An excessive boiler operating temperature can activate a thermostat to switch off the boiler This thermostat automatically resets when the boiler has cooled down sufficiently Do not attempt to repeatedly start the boiler using the manual reset buttons as persistent failure indicates a fault requiring the attention of a service engin...

Страница 11: ...faction please check the following points before calling for a service engineer 1 Oil level in the tank 2 Power to the boiler 3 All control settings Technical support In the event of a appliance fault or breakdown please contact Worcester Bosch Group appointments team on 0330 123 9339 Your advisor will arrange for an engineer to call with the minimum of delay under normal circumstances this will b...

Страница 12: ...ng economically The boiler is designed to provide a high level of comfort while keepingoilconsumptionandtheresultingenvironmentaleffect as low as possible Thecentralheatingcontrolontheboilershouldbesetaslowas possible while still maintaining a comfortable room temperature The temperature of each room can be set individually using the thermostatic radiatorvalves except theprimaryroomwith the room t...

Страница 13: ... Interval Record in the back of the Installation Commissioning and Servicing manual BoschThermotechnology Ltdwillnot accept responsibility fordamagecausedbyfaultyinstallation neglect misuseor accidentaldamage and non observance of theinstructions contained in the Installation and Users Instructions manuals The boiler has been used only for normal domestic purposes for which it was designed This gu...

Страница 14: ...14 Greenstar Danesmoor Utility ErP 6 720 813 330 2014 09 Notes ...

Страница 15: ...15 Greenstar Danesmoor Utility ErP 6 720 813 330 2014 09 Notes ...

Страница 16: ...ndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a brand name of Bosch Thermotechnology Ltd worcester bosch co uk 6 720 813 330 2014 09 General checks before calling a Service engineer 1 Oil level in the tank 2 Power to the boiler 3 All control settings Please read the fault section of the manual before contacting our service team No boiler fault is found on over 30 of all service...

Отзывы: