Central heating systems

All radiators must be heated at an even rate. If the top of a radiator is at a lower temperature than the bottom then it should be bled 
by releasing air through the bleed screw at the top of the radiator. 
Ask your installer to show you how this is done.
This boiler is fitted to a sealed system. Should water leaks be found or if excessive bleeding is required, then a service engineer must 
be contacted to inspect the installation and rectify any fault.
Only additives that are compatible with aluminium may be used in the system. Any incompatible additive used will invalidate the 
guarantee.

Pluming and Condensate drain

This is a condensing boiler and the flue terminal will, at times give out a plume of water vapour. This is quite normal.
The boiler produces condensate which is discharged regularly by a syphon within the boiler via a plastic pipe to a drain. This pipe 
must not be blocked or altered in any way.

Room thermostat / programmer

A room thermostat / programmer must be fitted to control the central heating. This controls the times and temperatures of the 
central heating, preventing the boiler from firing unnecessarily. Refer to the instructions supplied with the thermostat and 
programmer for further information.

Thermostatic radiator valves

Thermostatic radiator valves must be fitted in sleeping accommodation. It is recommended that this type of valve is fitted to all but 
one of the radiators. The remaining radiator, where the room thermostat is located, must be uncontrolled and left open.

Pump over run function

After the boiler has finished a demand for central heating or hot water, the pump may continue to run for a short while to dissipate 
the heat from within the boiler.

Pump anti-seizure

If there has been no heating demand for 24 hours the boiler will run the system pump for a few seconds to reduce the possibility of 
pump seizure during long periods of inactivity.

SEDBUK

Seasonal Efficiency of Domestic Boilers in the UK.

Содержание GREENSTAR CDi CLASSIC 29CDi GC

Страница 1: ...FED DOMESTIC HOT WATER 6 720 803 600 2012 06 The appliances are for use with Natural Gas or L P G Catt II type C13 C33 Natural Gas 29CDi GC number 47 406 34 34CDi GC number 47 406 36 38CDi GC number 4...

Страница 2: ...tremely energy efficient offering you economical running costs and value for money It sits in SEDBUK Band A and is therefore amongst the top energy rated boilers available There is also the reassuranc...

Страница 3: ...ter BOILER OPERATION This boiler must only be operated by a responsible adult who has been instructed in understands and is aware of the boiler s operating conditions and effects COMBUSTIBLE AND CORRO...

Страница 4: ...ARK STANDARD TheBenchmarkinitiativeisacodeofpracticetoencouragethecorrectinstallation commissioning and servicing of domestic central heating boilers and system equipment A checklist is dispatched wit...

Страница 5: ...E E RESET BUTTON F ECO BUTTON DOMESTIC HOT WATER PRE HEAT ON OFF G HOLIDAY BUTTON H DOMESTIC HOT WATER TEMPERATURE CONTROL I CENTRAL HEATING TEMPERATURE CONTROL J SERVICE ENGINEER BUTTON ONLY K SERVIC...

Страница 6: ...When the burner is lit the green indicator light underneath the on off switch is illuminated The boiler runs for 15 minutes at minimum heating output to fill the condensate trap The display alternate...

Страница 7: ...ter will stay activated If the temperature within the boiler drops to 5 C the boiler will fire to avoid the possibility of freezing To activate frost protection B Leave master switch on B Turn the cen...

Страница 8: ...button until it is no longer illuminated To activate ECO mode B Press the ECO button until it is illuminated 3 7 HOLIDAY SETTING Activating the holiday setting will turn off the central heating syste...

Страница 9: ...e mains power indicator will stop flashing The boiler will function normally dependent on programmer and room thermostat settings If the fault cannot be cleared by pressing the reset button B Refer to...

Страница 10: ...key into the bottom of the charging link and push it upwards The arrow on the key shaft must be in line with the open padlock symbol on the charging link 3 Turn the filling key clockwise to the close...

Страница 11: ...eps 1 to 3 5 With filling key in locked position turn the water mains inlet knob white anticlockwise to open This fills the heating system with mains water 6 When the pressure gauge reads 1 5 bar turn...

Страница 12: ...re B Re pressurise the system refer to pages 10 Low temperature setting on the boiler controls B Increase settings on boiler controls Desired room temperature too high Radiators are too hot B Turn dow...

Страница 13: ...Safe registered personnel Error code Description A7 Hot water NTC sensor defective A8 Break in communication to TD200 or and DT10 b1 Code plug not detected C6 Fan speed too low E2 CH flow NTC sensor...

Страница 14: ...pe can be thawed by applying a hot water bottle a microwaveable heating pack the sort used for muscular aches and pains or a cloth soaked in hot water to the exterior of the pipe close to the point of...

Страница 15: ...ere has been no heating demand for 24 hours the boiler will run the system pump for a few seconds to reduce the possibility of pump seizure during long periods of inactivity This is usually more frequ...

Страница 16: ...ist Our Field Service Engineer finds no fault with the boiler The cause of breakdown is misuse or with other parts of your plumbing heating system or with equipment not supplied by Worcester Bosch Gro...

Страница 17: ...atic radiator valves If damaged replace the plastic tops used to adjust the thermostatic radiator valve It is also advisable to manually adjust all thermostatic radiator valves every 2 3 weeks to prev...

Страница 18: ...stic purposes for which it was designed This guarantee does not affect your statutory rights GUARANTEE REGISTRATION Your Greenstar boiler carries a two year guarantee against faulty material or manufa...

Страница 19: ...to a drain This pipe must not be blocked or altered in any way Room thermostat programmer A room thermostat programmer must be fitted to control the central heating This controls the times and temper...

Страница 20: ...0 SPARES 01905 752571 LITERATURE 0844 892 9800 TRAINING 01905 752526 SALES 01905 752640 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0844 892 9900 Worcester Bosch Group is a brand...

Отзывы: