Technical Specifications/Logs
65
Greenstar 8000 Life – 6720883865 (2019/02)
Batteries
Batteries must not be disposed together with your household waste.
Used batteries must be disposed of in local collection systems.
12
Technical Specifications/Logs
12.1
Technical data
12.1.1 Specifications Combi
Greenstar 8000 Life
GR8300iW 30
GR8300iW 35
Unit
Natural gas
Propane
1)
Natural gas
Gas flow maximum rate – 10 minutes from lighting
Natural Gas
2)
m
3
/h
3.2
–
3.6
–
Propane Gas (LPG)
kg/h
–
2.3
–
2.7
Central Heating (CH)
Maximum rated heat input (net) (Q
max
)
kW
30.2
30.2
34.4
34.4
Maximum rated heat output 40/30 °C
kW
31.2
31.2
35.2
35.2
Maximum rated heat output 50/30 °C (P
cond, max
) kW
31.0
31.0
35.0
35.0
Maximum rated heat output 80/60 °C (P
max
)
kW
29.6
29.6
33.7
33.7
Minimum rated heat input (net) (Q
min
) kW
3.0
3.0
5.1
5.1
Minimum rated heat output 40/30 °C
kW
3.3
3.3
5.5
5.5
Minimum rated heat output 50/30 °C (P
cond, min
)
kW
3.2
3.2
5.5
5.5
Minimum rated heat output 80/60 °C (P
min
)
kW
2.9
2.9
5.0
5.0
Maximum flow temperature
°C
70
70
70
70
Maximum flow temperature possible
°C
82
82
82
82
Maximum permissible operating pressure (PMS)
bar
2.5
2.5
2.5
2.5
Available pump head at 20 °C system temperature rise
m
2.0
2.0
2.0
2.0
Domestic Hot Water DHW
Minimum heat input
kW
3.0
3.0
5.1
5.1
Maximum rated heat input (net) (Q
n
W)
kW
30.2
30.2
34.4
34.4
Maximum rated heat output (P
n
W)
kW
30.2
30.2
34.4
34.4
Maximum mains inlet pressure (standing pressure PMW)
bar
10
10
10
10
Minimum mains inlet pressure (working) for max. flow
bar
2.3
2.3
3.2
3.2
Minimum mains inlet pressure (working) for operation
bar
0.2
0.2
0.2
0.2
Minimum required flow to activate DHW demand
l/min
1.9
1.9
1.9
1.9
DHW temperature range
°C
35-60
35-60
35-60
35-60
Maximum cold water inlet temperature
°C
60
60
60
60
Maximum DHW flow rate - 40 °C rise ± 15%
3)
l/min
11
11
13
13
Flue
Flue gas temperature max. load DHW demand
°C
67/56
67/56
72/56
72/56
Flue gas temperature 80/60 °C, max/min load
°C
67/56
67/56
72/56
72/56
Flue gas temperature 40/30 °C, max./min load
°C
49/31
49/31
52/31
52/31
CO
2
level at max. rated heat output (after 10 minutes)
%
9.5
10.8
9.5
10.8
CO
2
level at min. rated heat output (after 10 minutes)
%
8.6
10.2
8.6
10.2
NO
x
class
–
6
6
6
6
NO
x
rating (EN 15502-1)
mg/kWh
≤ 40
≤ 40
≤ 40
≤ 40
Condensate
Maximum condensate rate
l/h
3.5
3.5
4.1
4.1
pH value, approx.
–
4.5 – 5.0
4.5 – 5.0
4.5 – 5.0
4.5 – 5.0
Electrical
Electrical power supply voltage
a.c. V
230
230
230
230
Frequency
Hz
50
50
50
50
Maximum power consumption (running)
W
150
150
108
108
Maximum power consumption (stand-by)
W
1
1
1
1
Energy efficiency index (EEI) heating pump
–
≤ 0.23
≤ 0.23
≤ 0.23
≤ 0.23
General data
Expansion vessel capacity
l
10.0
10.0
10.0
10.0
Expansion vessel pre-charge pressure
bar
1.0
1.0
1.0
1.0
Appliance protection rating
4)
IP
X4D
X4D
X4D
X4D