Pre-Installation
Greenstar 8000 Life – 6720883865 (2019/02)
14
Fig. 10 Bathroom installations
[1]
Zone 1
[2]
Zone 2
[2*]
Without the end wall, zone 2 must extend 600mm from the bath
[A]
600mm radius from the bath or shower
4.3.3
Appliance clearances
Appliance clearances
• The following details covering the installation, service and
maintenance clearances for the appliance.
CAUTION:
Risk of damage to appliance or property
The appliance will overheat if the clearance space around the appliance
is restricted by objects.
▶ Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the appliance.
▶ Do not store any combustible materials on or next to the appliance,
such as clothes, towels, paper or plastic bags.
Fig. 11 Appliance minimum clearances
Table 7
[*]
Height for either 60/100 flue or 80/125 flue
Appliances in compartments
Follow the latest requirements of BS6798 and BS5440 and note:
• Minimum clearances must be maintained.
• An access door is required to install, service and maintain the
appliance and any ancillary equipment.
• If the appliance is installed in an unventilated airing/storage
cupboard, there is no requirement to make a partition between the
appliance and the storage space as long as the minimum clearances
around the appliance are maintained.
4.4
Flue systems considerations
WARNING:
Flue systems
Possible flue gas escape
▶ Use Worcester, Bosch Group approved Condensfit II flue systems
only, no other manufacturer’s flue have been tested or approved for
use with Worcester, Bosch Group appliances.
CAUTION:
Concealed flue systems:
▶ Where a flue system is going to be concealed, provision must be
made for service and inspection.
▶ Voids containing concealed flues must have at least one inspection
hatch no less than 300mm square.
▶ Flue joints within the void must not be more than 1.5 metres from the
edge of the inspection hatch.
▶ Inspection hatches should be located at changes of direction.
▶ If this is not possible, bends should be viewable from both directions.
Refer to the manual supplied with the Worcester, Bosch Group flue kit for
complete installation instructions.
Flue kit part numbers
Minimum clearances
Description
Dimensions (mm)
X
Appliance width
440
Y
Appliance height
780
Z
Appliance depth
365
0010017086-001
2*
1
2
1
2
2
1
600mm
600mm
600mm
2250mm
2250mm
2*
A
A
A
0010012940-001
Installation/Maintenance
1
Overall clearance height
1,150/1,190 *
2
Overall clearance depth
965
3
In front of appliance
600
4
Overall clearance width
450
5
Above the appliance
170/210 *
6
Either side of appliance
5
7
Below the appliance
200
8
Compartment depth
385
9
Appliance to removable door
20
Part number
Flue Ø
Description
7 738 112 869 60/100
Telescopic horizontal flue kit (Silver)
7 716 191 082 60/100
Telescopic horizontal flue kit
7 716 191 171 60/100
Extended telescopic horizontal flue kit
7 733 600 048 60/100
Horizontal high level telescopic flue kit
7 719 003 702 80/125
Telescopic horizontal flue kit
Minimum clearances
Description
Dimensions (mm)