Prepare for operation
7
Greenstar 4000 – 6 720 891 171 (2020/09)
3
Prepare for operation
3.1
Sealed heating system
Appliances that can be connected to sealed heating systems are pre-
pressurised before operation, this pressure must be maintained for safe
use of the appliance.
▶ Check regularly that the pressure is maintained.
▶ Re-charge the system if the pressure indicator reads less than 0.8
bar.
▶ If a permanent significant decrease or increase in pressure is shown
on the pressure indicator, contact your installer or maintenance
engineer.
Pressure indicator
▶ Type of pressure indicator for the system pressure.
– Pressure gauge (an analogue dial showing the pressure)
– Pressure menu (a digital readout of the pressure)
▶ Your appliance may have one or both types of methods to indicate the
system pressure. The type of method used on this appliance will be
detailed in the following section.
3.1.1
Checking the system pressure
The appliance pressure menu indicates the pressure within the heating
system during standby and operating periods.
Your installer will advise you of the optimum operating pressure.
▶ Check the system pressure on the pressure menu.
–
Static pressure
is when appliance is cold and has not fired for
heating or hot water. This will generally be 0.8 - 1.7 bar.
–
Operating pressure
is when the appliance is firing for a heating
or hot water demand. This will generally be 1 - 2 bar.
Fig. 2
Checking the operating pressure
[1]
Static pressure range.
[2]
Operating pressure range.
[3]
Pressure menu indicator.
The pressure menu can be accessed via the
Boiler status
screen.
▶ Press the menu key (
). Select and confirm
Boiler status
.
The screen
Boiler status
with a pressure menu indicator appears.
▶ Check the system pressure on the display.
–
Indicator in red zone
: pressure is too low or too high.
–
Indicator in yellow zone
: pressure is low or slightly too high.
–
Indicator in green zone
: pressure is normal.
▶ Top up the heating water, if the pressure is low or too low.
3.1.2
Low pressure indication
Low pressure (shaded area [A]) will be indicated on the appliance:
• The pressure indicator is within the area between 0 and 0.79 bar in
the pressure menu display (left hand yellow and red zone).
• Additionally there is a message displayed.
Fig. 3
Low pressure indication
[A]
Low pressure area
3.1.3
Constantly re-pressurising the system
Constantly having to re-pressurise the heating system should be
investigated as it is an indicator of potential leaks and the concentration
of inhibitor protection in the system will be reduced; this can result in
corrosion within the heating system, reducing efficiency and increasing
contaminates.
▶ Check for leaks on heating system (pipework and radiator valves).
▶ Contact your installer or maintenance engineer if a recurring
significant decrease or increase in pressure is indicated on the
pressure screen.
System pressure increasing:
▶ If the system pressure repeatedly increases and you need to vent air
from the radiators, refer to
Min
Max
0010033762-001
3
1
2
0010033766-001
Fault - 1017
Pressure: 0.2 bar
System pressure
too low
A
Max
Min