Страница 1: ...6 720 891 171 2020 09 UK IE User Instructions Gas fired condensing system appliance Greenstar 4000 GR4700iW S...

Страница 2: ...e of exceptional quality and proven reliability Our products employ the latest technologies and they are reliable extremely energy efficient offering you economical running costs and value for money T...

Страница 3: ...Symbols on the display 10 4 4 Adjusting the appliance flow temperature 10 4 4 1 Setting the flow temperature 10 4 5 Setting the DHW heating 10 4 6 Setting the heating control device 10 4 7 Operating t...

Страница 4: ...tion Observe the safety instructions and warnings H Determined use The product may only be used for the heating of boiler water and for DHW heating Anyotheruseisconsideredinappropriate Weassume noliab...

Страница 5: ...system will invalidate the guarantee Do not modify the appliance or flue system in any way Worcester Bosch Group accepts no liability arising from any such actions This does not affect your statutory...

Страница 6: ...e and to ensure the appliance continues to operate at peak efficiency and performance it is essential that servicing and maintenance checks are performed at leastonceayearbyacompetentengineerinaccorda...

Страница 7: ...erating pressure range 3 Pressure menu indicator The pressure menu can be accessed via the Boiler status screen Press the menu key Select and confirm Boiler status The screen Boiler status with a pres...

Страница 8: ...e system fill isolation valves 5 are opened the handle screwdriver slot is in line with the valve The pressure menu indicator moves and the displayed message may change 6 Turn the handles screwdriver...

Страница 9: ...crease settings 4 d button Return back 5 ok button Selection save settings 6 Menu button 7 Hot water button Hot water mode on off adjusting the hot water temperature 8 Heating button Heating mode on o...

Страница 10: ...s is useful for large longer demand periods 4 6 Setting the heating control device Observe the operating instructions of the heating controller This shows you how to set the room temperature how to he...

Страница 11: ...co Preheat Eco Appliancewillheatthecylinderifthetemperature fallsapproximately10 Cbelowthesettemperaturefor hot water Preheat Appliance will heat the cylinder if the temperature is approximately 5 C b...

Страница 12: ...st The heating system can freeze up after a prolonged period e g during a power failure switching off the power supply faulty fuel supply boiler fault etc Ensure that the heating system is in constant...

Страница 13: ...appliance such as clothes towels paper or plastic bags Fig 7 Appliance minimum clearances Table 8 Appliance minimum clearances 0010012940 001 Minimum clearance Description Dimensions mm X Appliance wi...

Страница 14: ...d within 300mm of a door way and the door frame is the only obstruction Minimum clearances must be observed to any obstruction surface dark shaded areas figures 8 and 9 Fig 8 Reduced front maintenance...

Страница 15: ...liance fault or breakdown please contact Worcester Bosch Group appointments team on 0330 123 9339 Your advisor will arrange for an engineer to call with the minimum of delay under normal circumstances...

Страница 16: ...troubleshooting WARNING Caution must be exercised when venting radiators or adjusting system pressure after commissioning of your boiler Do not repeatedly vent your radiators if symptoms persist cont...

Страница 17: ...nstantly have to top up your boilers pressure Can you confirm that the filling link is not stuck open passing water in any way Does system pressure increase when the boiler is on Does the system press...

Страница 18: ...es your household waste disposal service or the retailer where you purchased the product You can find more information here www weee bosch thermotechnology com Batteries Batteries must not be disposed...

Страница 19: ...the appliance was correctly commissioned and where appropriate serviced to the satisfaction of Bosch Thermotechnology Ltd These should be documented in the commissioning and service records in the Ins...

Страница 20: ...nd high temperature regime 1 1 High temperature regime means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet P4 kW 24 21 18 At 30 of rated heat output and low temper...

Страница 21: ...h temperature regime means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet P4 kW 15 12 At 30 of rated heat output and low temperature regime 2 2 Low temperature mean...

Страница 22: ...gh temperature regime means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet P4 kW 24 21 18 At 30 of rated heat output and low temperature regime 2 2 Low temperature...

Страница 23: ...gh temperature regime means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet P4 kW 15 12 At 30 of rated heat output and low temperature regime 2 2 Low temperature mea...

Страница 24: ...Toprovideservicessuchas salesandmarketingservices contractmanagement paymenthandling programming datahostingandhotlineserviceswecancommissionand transfer data to external service providers and or Bosc...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...Kingdom Tel 0330 123 9559 worcester bosch co uk TECHNICAL SUPPORT 0330 123 3366 RENEWABLE SUPPORT 0330 123 9229 CONTROLS AND CONNECTIVITY TEAM 0330 123 3641 APPOINTMENTS 0330 123 9339 SPARES 0330 123...