No lights at all
Other faults not covered by above
FAIL POINT C
FAIL POINT B
FAIL POINT E
FAIL POINT J
FAIL POINT K
FAIL POINT A
FAIL POINT D
FAIL POINT F
FAIL POINT G
FAIL POINT H
FAIL POINT I
No green light
(Red lights work)
No light
(Other lights work)
Light on constant
(CH knob in OFF
position)
2 lights flashing slowly
Flashing slow
Flashing fast
Flashing fast
No light
(Other lights work)
No red lights
(Green light working)
LIGHT SITUATION DURING FAULT
POWER ON
(Green)
CH DEMAND
(Red)
HW DEMAND
(Red)
BURNER ON
(Red)
The electronic control system for this appliance uses the four
lights on the facia. These show the normal operating status and,
by flashing, help to provide a fault diagnostic system. With
individual or groups of lights being permanently off, on or
flashing, every normal fault can be identified.
Slow Flash - One per second
Can be cleared by pressing the facia reset button for at least one
second.
Fast Flash - Five per second
Can be cleared by removing the fault and/or switching the
mains off and on.
Note: This information is for guidance only. Worcester Heat
Systems cannot be held responsible for costs incurred by per-
sons not deemed to be competent.
Preliminary Checks.
Electrical system checks are the first actions to be
carried-out during a fault finding procedure. On
completion of the Service or a fault finding task which has
necessitated the breaking and remaking of electrical
connections, check (a) Earth Continuity, (b) Short Circuit, (c)
Polarity, (d) Resistance to Earth.
INDICATOR
RESULT
CAUSE
ACTION
CH Light Flashes
Burner Lock - Out.
Flame Detect Fault.
Press Facia Reset Button For 1 Second.
Slow
Internal TestFault.
CH & DHW Lights Flash
Primary Overheat.
Overheat Thermostat Operated in
As Above.
Slow
Demand status.
CH Light Flashes
Sensor Fault.
Primary (CH) or DHW Sensor Open
Switch Mains Supply Off /On
Fast
or Short Circuit.
or Rectify Fault.
Internal Reference Voltage Error.
DHW Light Flashes
Air Pressure Fault or APS Permanently Closed.
Switch Mains Supply Off/On
Fast
Blocked Flue or
APS Does not Close.
or Recify Fault.
Water Pressure Fault
APS Open While Burner is On.
18. Fault Finding
Fault Finding Chart
Select the appropriate indicator light situation. Refer to the appropriate section of the chart. This system assumes that the appliance has
been operating correctly upto the point of failure.
Other faults not covered by above
FAIL POINT K