background image

4

Key to symbols and safety instructions

Greenstar i 

ErP 

– 6 720 806 946 (2015/03)

1

Key to symbols and safety instructions

1.1

Key to symbols

Warnings

The following keywords are defined and can be used in this 
document:

NOTICE

 indicates a situation that could result in damage to 

property or equipment.

CAUTION

 indicates a situation that could result in minor to 

medium injury.

WARNING

 indicates a situation that could result in severe 

injury or death.

DANGER

 indicates a situation that will result in severe 

injury or death.

Important information

Additional symbols

Examples of additional symbols used

A numbered step in an action sequence

A sequence of numbered steps or actions carried out in a 
specific order to complete a task.
1. First action
2. Second action
3. Third action

etc.

A step in an action sequence

A sequence of defined actions or steps carried out in order to 
complete a task.
▶ Action
▶ Next  action
▶ etc

A reference to a related part in the document or to other 
related documents.

To refer the reader to a specific figure/table/section within the 
manual.

 e.g. figure 1.

A reference number to identify or refer to a part or item.

In a related figure, items or parts identified by a sequential 
number.

List entries, first and second levels

A single component/item

A component/list, made up of multiple parts/items.
– Sub component or sublist of main component/list.
– etc.

1.2

Safety precautions

If you smell gas:

A gas leak could potentially cause an explosion. If you smell gas, 
observe the following rules.

▶ Prevent flames or sparks:

– Do not smoke, use a lighter or strike matches.
– Do not operate any electrical switches or unplug any 

equipment.

– Do not use the telephone or ring doorbells.

▶ Turn off the gas at the meter or regulator.
▶ Open windows and doors.
▶ Warn your neighbours and leave the building.
▶ Prevent anyone from entering the building. 
▶ Well away from the building: call the National Gas 

Emergency Service on 0800 111 999.

▶ L.P.G. boilers: Call the supplier’s number on the side of the 

gas tank.

Appliance operation:

This appliance can be used by children aged from 8 years and 
above and persons with reduced physical, sensory or mental 
capabilities or lack of experience and knowledge, if they have 
been given supervision or instruction concerning the use of the 
appliance, in a safe way, and understand the hazards involved.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children 
without supervision.

Safety instructions in this document are 
framed and identified by a 
warning triangle which is printed on a grey 
background. 

This symbol indicates important information 
where there is no risk to people or property.

Symbol

Meaning

1.

a numbered step in an action sequence

a step in an action sequence

a reference to a related part in the document or to 
other related documents

  a reference number to identify or refer to a part or 

item

a  list  entry

a list entry (second level)

Table 1

1

Содержание Greenstar 25i ErP 47-406-60

Страница 1: ...ou smell gas Well away from the building call the National Gas Emergency Service on 0800 111 999 L P G boilers Call the supplier s number on the side of the gas tank These appliances are for use with...

Страница 2: ...g combination appliance manufactured by Worcester Bosch Group Thecompanypridesitselfonmanufacturingappliances to the strictest quality control standards throughout every stage of production Worcester...

Страница 3: ...temperature 15 3 3 2 Setting the flow temperature for the domestic hot water 15 3 3 3 Mid point domestic hot water temperature 16 3 3 4 Domestic hot water eco and preheat modes 16 3 3 5 Domestic hot...

Страница 4: ...ponent list etc 1 2 Safety precautions If you smell gas Agasleakcouldpotentiallycauseanexplosion Ifyousmellgas observe the following rules Prevent flames or sparks Do not smoke use a lighter or strike...

Страница 5: ...mark Checklist The completed Benchmark Checklist will be required in the event of any guarantee work and may be required by the local Building Control Inspector 2 3 Benchmark standard The Benchmark in...

Страница 6: ...unction button ECO toggles domestic hot water preheat ON OFF OK menu confirmation 4 Info Return Spanner button Multi function button Info Information menu access Return return to previous screen Spann...

Страница 7: ...scroll down scroll downwards through menu items 9 Central heating settings decrease button Decrease temperature decrease the desired flow temperature 10 Central heating settings Increase button Incre...

Страница 8: ...utton Confirms a selection Back button To return to the previous option or menu 5 Engineer function buttons Spanner button Service menu function button only Chimney sweep button Engineer service and s...

Страница 9: ...s status diagnostic code and short description information Right hand arrows text display Use domestic hot water arrow buttons to alter the menu item Flashing T text display Appliance in component tes...

Страница 10: ...ic code during a fault condition Service mode Displays when a qualified service engineer is in the service menus Burner on The appliance is in operation and the flame is alight Centigrade Displays nex...

Страница 11: ...aximum domestic hot water output kW Maximum domestic hot water output kW set on the appliance i6 Domestic hot water flow detected A minimum flow rate of approximately 2 9 l m has been detected by the...

Страница 12: ...menus 270 Power up mode appliance is powering up 283 Burner starting The boiler prepares for a burner start The fan and the pump are being controlled 284 Gas valve s opened flame must be detected with...

Страница 13: ...ppliance flow temperature for the central heating system The home screen will show the current appliance temperature 1 Press the central heating increase or decrease adjustment buttons to select the d...

Страница 14: ...rature 3 2 4 Turning the central heating off during the summer To turn your central heating off during warm periods Set the programmer to OFF or Turn the room thermostat temperature down to minimum 3...

Страница 15: ...temperature for the domestic hot water The home screen will show the current appliance temperature 1 Press the hot water increase or decrease adjustment buttons to select the desired flow temperature...

Страница 16: ...the home screen 3 or Wait 4 seconds for auto confirm and the display will return to the home screen 3 Fig 8 Hot water economic value 3 3 4 Domestic hot water eco and preheat modes Preheat mode the hot...

Страница 17: ...mer Programmer hot water channel ON periods Preheat mode is active and indicated on the appliance display 2 Programmer hot water channel OFF periods Eco mode active and indicated on the appliance disp...

Страница 18: ...ing Contact your installer or maintenance engineer if a permanent significant decrease or increase in pressure is indicated on the pressure gauge The filling method will be one of three types Optional...

Страница 19: ...needle 1 on the appliance pressure gauge reads less than 1 bar re charge the system 2 Pull the blue lever down to start the filling process 3 Monitor the pressure gauge on the appliance facia Fig 12 K...

Страница 20: ...the two sections of the filling loop 3 Turn the white knob to the left this will allow water to fill the system 4 When the pressure shown on the appliance facia pressure gauge reaches between the 1 a...

Страница 21: ...he handle screwdriver slot through 90 to open the valves 4 The handle screwdriver slot will be in line with the valves Fig 14 External filling loop 5 When the pressure reaches between the 1 and 1 5 ba...

Страница 22: ...lue CAUTION Restricted space The appliance may overheat Do not restrict this space with the addition of cupboards shelves etc next to the appliance NOTICE Combustible and corrosive materials Chemicall...

Страница 23: ...ormance it is essential that your appliance receives regular servicing and maintenance checks from a competent person beyond the initial guarantee period If your Greenstar gas fired appliance should f...

Страница 24: ...ssurise the heating system Low system water pressure Re pressurise the system refer to page 19 Desired room temperature too high Thermostatic radiator valves are set to high Turn down thermostatic rad...

Страница 25: ...e appliance will return to normal operation Iftheresetwasnotsuccessfulthenthealertcodewillbedisplayedagain and theblueoperation faultlightwillcontinuetoflash Fig 17 Reset confirmation Due to the inter...

Страница 26: ...omer service section 8 Fault or breakdown This appliance is supported in the UK and Eire by Worcester Bosch Group Specialist service engineers are available to attend a breakdown occurring on this app...

Страница 27: ...Room thermostats Reducing the setting of the room thermostat by 1 C can reduce fuel consumption by up to 10 New control systems Upgrade your heating control system if necessary with the latest equipme...

Страница 28: ...out to the satisfaction of Bosch Thermotechnology Ltd when requested These should be documented as a part of the Benchmark Checklist The appliance has been used only for the normal domestic purposes f...

Страница 29: ...dregularlybyasyphonwithintheapplianceviaaplasticpipetoadrain This pipe must not be blocked or altered in any way Room thermostat programmer A room thermostat programmer must be fitted to control the c...

Страница 30: ...30 Greenstar i ErP 6 720 806 946 2015 03 Notes...

Страница 31: ...31 Greenstar i ErP 6 720 806 946 2015 03...

Страница 32: ...SPARES 0330 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a bran...

Отзывы: