Technical information

Technical information

Factory settings

The table displays the factory values (F value) of the 
settings that you, as a customer, (K) can change via the 
customer menus Menu and Advanced menu.

Read the table as follows:
To fi nd the settings for Holiday go to the Advanced menu
select Temperature, then select Time limited settings and 
then Holiday

Menu

Level

F value

Temperature increase/decrease

K

(no change)

Room temperature setting

K

20ºC

Extra hot water

K

0  h

Advanced menu

Level

F value

Temperature

Heating system temperature

----"----\Heat curve

K

V=20,0ºC 
H=55,2ºC

----"----\Hysteresis  

----"----\----"----\Maximum

K

16ºC

----"----\----"----\Minimum K

4ºC

----"----\----"----\Time factor

K

10

Room sensor settings (T5)

----"----\Room temperature setting

K

20ºC

----"----\Room sensor infl uence

----"----\----"----\Change factor

K

5

----"----\----"----\Blocking time

K

4 h

Time limited settings

----"----\Time control heating

K

Off

----"----\----"----\Day and time

K

----"----\----"----\Change in temperature

K

-10ºC

----"----\Holiday

K

Off

----"----\----"----\Date

K

----"----\----"----\Change in temperature

K

-10ºC

Heating season

----"----\Heating season limit

K

18ºC

----"----\Delay

K

4 h

----"----\Direct start limit

K

10ºC

Heating, maximum operating time at hot 
water requirement

K

20 min

Advanced menu

Level

F value

Hot water (T3)

Extra hot water

----"----\Number of hours

K

0

----"----\Stop temperature

K

65ºC

Hot water peak

----"----\ Interval

K

0 days

----"----\Start time

K

03:00

Time control hot water

K

Off

Setting the clock

Set date

K

Set time

K

Alarm

Alarm log

----"----\Delete alarm log?

K

No

Access level

K

0

Return to factor y settings

K

No

Deactivate alarm buzzer

K

No

Program version

K

xx.xx.x

Содержание GREENSOURCE

Страница 1: ...WORCESTER GREENSOURCE Air to Water Outdoor Heat pump 6 kW 7 kW 9 5 kW USER MANUAL GB IE GB IE Please read carefully prior to installation and user guide...

Страница 2: ...User manual for the Worcester Greensource heat pumps Worcester 16 06 08 Part number 8 716 115 328 Issue a Copyright 2008...

Страница 3: ...rview 12 Menu levels 13 Menu 13 Menu overview 13 Set the heating 14 Extra hot water 14 Temperatures 15 Advanced menu 16 Overview 16 Set the heating 17 Set the desired room temperature 19 Time limited...

Страница 4: ...ing basic maintenance actions Initially you should perform these actions on your own This manual describes each step in detail If the problem remains you should contact your installer This guide conta...

Страница 5: ...ing point of different liquids varies with pressure the higher the pressure the higher the boiling point For example water boils at 100 C at normal pressure Double the pressure and water boils at 120...

Страница 6: ...tted in this process to the heating system or the hot water After the condenser the refrigerant which is now in liquid form continues through a drying filter The drying filter is used to collect any m...

Страница 7: ...e additional electric heater is integrated in the Greensource hot water distribution unit The heat pump is installed outside the hot water distribution unit is installed indoors Component parts of the...

Страница 8: ...automatically switched off Hot water is given priority over heating water In a house with water based heating a difference is made between heating water and hot water The heating water is for radiato...

Страница 9: ...rce hot water distribution unit the control unit sets itself for this operation This means that the heat pump operates with additional heat from the hot water distribution unit and that the hot water...

Страница 10: ...unit The curve indicates the flow temperature for heating water in relation to the outdoor temperature Selecting a lower curve gives a lower flow temperature and therefore higher energy savings Contr...

Страница 11: ...u tion unit Menu dial Switch ON OFF Menu window Status LED Status LED The control cabinet s status LED is on the outside of the unit LED lights green Switch ON OFF in ON position LED flashes green Swi...

Страница 12: ...e menu dial clockwise to move down through the menus Turn the menu dial anti clockwise to move up through the menus When the desired menu is highlighted press the menu dial to confirm your selection C...

Страница 13: ...rease decrease or Room temperature setting if you have a room sensor is shown Extra hot water is only displayed if you have a hot water heater connected Menu Menu levels The menus are divided into dif...

Страница 14: ...et the desired room temperature Extra hot water With the hot water distribution unit you can temporarily increase the tem perature of the hot water to approximately 65 C via the function Extra hot wat...

Страница 15: ...ows 32 C Outdoor sensor T2 Shows the outdoor temperature Some deviation may occur due to thermal radiation from the house to the installed outdoor sensor In the example the sensor shows 2 C Hot water...

Страница 16: ...ng installation These are provided in the Advanced menu To the right you will find all functions under Advanced menu To access Advanced menu press the menu dial and keep it pressed in for at least 5 s...

Страница 17: ...to the heating system Outdoor temperature The outdoor temperature determines how much heating the heat pump should produce The outdoor sensor sends signals to the control unit which then affects the h...

Страница 18: ...then marked by pressing the dial The H value can now be changed by turning the dial When you are happy with the H value press the dial and select Save 4 It may also be necessary to change a specific...

Страница 19: ...reater influence from the room sensor After a heat lowering period e g time control or holiday the room sensor influence is blocked for a set time factory setting is 4 hours Min 0 and max 24 hours The...

Страница 20: ...Heating season limit can be adjusted factory setting 18 C min 10 C max 35 C as can the delay before activation factory setting 4 hours min 0 max 24 hours The delay means that the heat pump does not n...

Страница 21: ...save the change or Cancel to return without saving Read off the remaining time of Extra hot water by going toTimers Hot water peak Recurring increase in the hot water temperature The Hot water peak m...

Страница 22: ...y before defrost Displays the remaining time before defrost is permitted Heating maximum operating time at hot water requirement Displays the remaining time before the maximum time in heating mode is...

Страница 23: ...ect Return to factory settings Select Yes and then Save to save the setting or Cancel to return without saving When restoring the factory settings while in any of the customer levels the settings made...

Страница 24: ...the cover against your body 3 Lift the cover upwards to release the lower edge Remove dirt and leaves Over time leaves and other dirt can enter the heat pump You can easily remove any dirt through th...

Страница 25: ...e fins Also remove any snow or ice from the grille on top of the heat pump The pump is supplied with defrost functions which can be set by the installer In the event of any problems these may need adj...

Страница 26: ...unit The additional electric heater takes over the heating production during emergency operation Heating can therefore be obtained until the installer or authorised service technician has remedied the...

Страница 27: ...rectify it The alarm log see Advanced menu shows the alarms and warnings that have occurred List of all alarms What to do if a fault occurs List of all warning windows Alarm window Tripped low pressu...

Страница 28: ...systems with thermostat valves these should be fully open and in underfloor heating systems at least half of the coils should be fully open 4 Possibly increase the pump speed 5 Contact your installer...

Страница 29: ...at 3 Contact your installer at repeated alarms Fault on additional heat for heating system Possible cause 1 Additional heater overheat protection has tripped Action 1 Select Acknowledge 2 Reset the ov...

Страница 30: ...pump has not stopped 2 Check that all the valves are open In heating systems with thermostat valves these should be fully open and in underfloor heating systems at least half of the coils should be f...

Страница 31: ...temperature of the return water from the heating system becomes too high The limit lies at approximately 59 C Possible cause 1 The heat setting is set so high that the heating system s return tempera...

Страница 32: ...nd limits the additional heat to the heat pump if the tempera ture of the return water from the heating system becomes too high The limit for additional heat lies at approximately 48 C Possible cause...

Страница 33: ...Minimum K 4 C Time factor K 10 Room sensor settings T5 Room temperature setting K 20 C Room sensor influence Change factor K 5 Blocking time K 4 h Time limited settings Time control heating K Off Day...

Страница 34: ...D characteristic MCB 2 Dimensions excl feet supplied min 20 mm max 30 mm depending on adjustment Example Greensource 6 kW Distance Lp ear dBa 1 metres 49 2 metres 43 4 metres 37 8 metres 31 Greensour...

Страница 35: ...ical information Temperature C k 40 154 300 35 111 700 30 81 700 25 60 400 20 45 100 15 33 950 10 25 800 5 19 770 0 15 280 5 11 900 10 9 330 15 7 370 20 5 870 25 4 700 30 3 790 35 3 070 40 2 510 45 2...

Страница 36: ...AINING 01905 752526 SALES 01905 752640 W E BSITE www worcester bosch co uk EXCELLENCE COMES AS STANDARD Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 01905 754624 Fax 01905 754619...

Отзывы: