Worcester Digistat Optimiser Скачать руководство пользователя страница 17

Installer Options

If you wish to change any of the Installer Options as

shown below, enter the Installer Option Menu from

Auto mode by pressing < and + simultaneously for 5

seconds.

Pressing < and + again for 5 seconds will exit the

Menu and return to Auto mode.

Once the Installer Options screen has been selected,

the < and > buttons allow you to scroll through the

Menu (shown below). The + and - allow you to

change values. Once a value has been changed

pressing > before exiting the Menu will save the new

setting. (The figure below shows Option 02 OFF).

Special Note:
If the Intelligent delayed start feature is

enabled, (Off changed to On in Installer option

06), please inform the end user of this feature.
The following special note has been added to

the user instruction to explain the adjustment

requirement:

When the delay period is operating, indicated by the

flame symbol flashing, pressing any button returns

the Digistat to auto mode allowing normal button

operation until the next time/ temperature event,

when it will resume the delay start mode or follows

the Holiday, Manual, Override or Off modes as

selected.
Changes to the installer options and pre-set 

programmes must be made with the flame symbol

NOT

flashing.

Installer

Options

Function

Select

Option

Default

02

Freeze protection

On

Off

On

04

Low Set Point C

5

High

Limit

5

05

High Set Point C

Low

Limit

32

32

06

Delayed Start (Energy

saving feature

On

Off

Off

10

System protection

On

Off

Off

11

System protection

time (Mins)

1

5

3

Option 02 - Freeze Protection

Freeze protection will switch on the heating if the

room temperature falls to 5°C and will then control

the temperature at 7°C even if the Digistat is in OFF

mode.

The Freeze Protection default in ON.

To switch off the Freeze Protection mode enter the

Installer Options Menu (Refer to Installer Options 02)

and change to OFF. Press > to accept.

Option 04 & 05 - Low and High Limit set points.

The user temperature set points defaults are High

32°C and Low 5°C, to change these limits enter the

Installer Options Menu

(Refer to Installer Options 04 & 05).

Option 06 - Intelligent Delayed Start

(Energy saving feature).

The Intelligent Delayed Start is an energy saving fea-

ture which automatically reduces the warm up time

for the heating system.
If enabled, the start time should be set an hour earli-

er than the time you want the property to reach the

set temperature.
Intelligent Start will delay that start time, by an

amount that it has calculated based on the actual

and set temperature.  
As the weather becomes milder, the start time is

delayed, so that fuel is not wasted bringing the room

up to temperature earlier than necessary.
The Digistat calculates approximately 10 minutes to

raise the temperature by 1°C, up to a maximum of

6°C.

Note:

Intelligent Delayed Start only applies in Auto mode.

Intelligent Delayed Start default is in OFF mode.

To switch ON Intelligent Delayed Start enter the

Installer Options Menu (see Installer Options 06).

Note:

The Intelligent Delayed start option is not suitable

for underfloor application.

Ensure Installer option 06 is set to OFF before final

commissioning for underfloor application.

DIGISTAT OPTIMISER
INSTALLER OPTIONS

OPERATING & INSTALLATION
INSTRUCTIONS

15

DIGISTAT OPTIMISER PROGRAMMER
7 DAY ROOM THERMOSTAT SYSTEM
716 114 519a (09.07)

Содержание Digistat Optimiser

Страница 1: ...GISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat FOR GREENSTAR 25 HE and GREENSTAR 30 HE MODELS INSTRUCTION MANUAL OPERATING AND INSTA...

Страница 2: ...LY AND SHOULD BE FOLLOWED EXCEPT FOR ANY STATUTORY OBLIGATION IF YOU ARE IN ANY DOUBT CONTACT WORCESTER BOSCH GROUP TECHNICAL HELPLINE THIS ACCESSORY MUST BE FITTED BY A COMPETENT PERSON FAILURE TO CO...

Страница 3: ...ETTINGS 5 ADJUSTING TIMES AND TEMPERATURES 5 USER OPTIONS 8 RECEIVER 11 OPERATIONAL CONTROLS 11 INSTALLATION 12 RECEIVER 12 DIGISTAT OPTIMISER 13 SETTING THE RF LINK 14 DIGISTAT OPTIMISER INSTALLER OP...

Страница 4: ...17 metres typically through two internal plasterboard walls a ceiling and one external cavity wall These distances are provided for guidance only many factors can affect the range of the transmitter i...

Страница 5: ...t is to find the lowest temperature settings that you are comfortable with at the different times you have chosen and then leave it alone to do its job The best way is to set low temperatures first sa...

Страница 6: ...me by using the or buttons Changing the temperature in this way will keep the Programmer set to your new temperature until the next pre programmed event at which time it will revert to programmed temp...

Страница 7: ...temperature to 21 C The temperature stays at 21 C until 14 00 when it drops down to 18 C At 16 30 the heating comes on to raise the tem perature to 21 C where it stays until 23 00 when the temperature...

Страница 8: ...required temperature Repeat above steps 2 3 until the 6 periods have been set for Monday 4 Once Monday has been set press once Repeat steps 2 3 until all 7 days of the week have been set 5 Once the fi...

Страница 9: ...unt down time and ambient room temperature 4 To exit the holiday mode press the or once to return to auto To switch the thermostat OFF Press the and simultaneously for 5 seconds until the OFF is displ...

Страница 10: ...to program 1 2 or 3 Enter user options select option 02 and use and keys to select desired program 1 2 or 3 1 program 1 2 program 2 and 3 program 3 Press to accept change Preset programs 2 and 3 are s...

Страница 11: ...day 4 4 time temp events per day and 6 6 time temp events per day Press to accept change Option 04 How to switch on off the automatic summer winter time change Twice a year the actual time is automat...

Страница 12: ...y adjust ments The default is OFF mode allowing you to adjust the Digistat To Lock the Digistat settings enter the User Options Menu Option 09 and select On and press to accept Once the User Options M...

Страница 13: ...LED will flash for approximately 7 sec ond every 5 minutes This confirms the RF signal is being received Small Receiver for 24i Junior 28i Junior and Si Mk II The heating can be switched ON or OFF at...

Страница 14: ...ERSON FAILURE TO COMPLY COULD LEAD TO PROSECUTION 1 Remove the blanking plate from the fascia by gently pulling the plate towards you to release the tabs 2 Present the receiver up to the fascia plug t...

Страница 15: ...nd mounting Mounting the digistat Location The Digistat is a radio frequency device and for best performance should be mounted in an open space no closer than 30cm to any metal objects including wall...

Страница 16: ...adio frequency RF link the receiver must be put into the LEARN MODE To set up the RF link proceed as follows 1 Press the OVERRIDE button until the green light is ON the appliance is now running in cen...

Страница 17: ...on the heating if the room temperature falls to 5 C and will then control the temperature at 7 C even if the Digistat is in OFF mode The Freeze Protection default in ON To switch off the Freeze Prote...

Страница 18: ...e the batteries When the batteries start to run low a battery icon will flash in the display to indicate low battery dur ing this time the Digistat will function normally Please replace with 2 x 1 5V...

Страница 19: ...up 4Transmitter batteries are the correct type fitted correctly and are not exhausted Fit new batteries if in doubt Hol Man Auto Day Digistat Optimiser Small Receiver Part Number 8 716 105 129 0 DIGI...

Страница 20: ...www worcester bosch co uk Worcester Bosch Group is a trading name of BBT Thermotechnology UK Ltd 8 716 114 519a 09 07 06515049001 CONTACT INFORMATION WORCESTER BOSCH GROUP TECHNICAL 08705 266241 SERVI...