Worcester 11 KW Скачать руководство пользователя страница 6

CONTROL UNIT

6 720 802 172 (2012/06)

6

7

CONTROL UNIT

The control unit controls and monitors the heating and hot water 
production with the heat pump and additional heat. The monitoring 
function shuts down the heat pump in the event of a fault so as to prevent 
damage to critical parts of the pump.

7.1

ADDITIONAL HEAT 

The additional heat becomes active in the event of emergency operation, 
extra hot water and hot water peak.

The additional heat is provided through electric additional heat.

The Multi module accessory is required for mixed additional heat.

The control unit will automatically activate the additional heat, when 
needed.

7.2

HOT WATER PRODUCTION

Hot water is heated in the domestic hot water cylinder and the control 
unit gives priority to hot water before production of heating water 
according to the settings that are made. The domestic hot water cylinder 
is fitted with a sensor that senses the temperature of the domestic hot 
water.

8

CONTROL PANEL

Settings for the control of the heat pump are made with the control unit's 
control panel, which also provides information about current status.

8.1

PANEL OVERVIEW

Fig. 3

The control panel

[1]

On/Off button

[2]

Mode button

[3]

Info button

[4]

Menu dial

[5]

Status lamp

[6]

Return button

[7]

Menu button

[8]

Menu display

8.2

ON/OFF BUTTON

Use the On/Off button to turn the heat pump on and off.

8.3

STATUS LAMP

8.4

MENU DISPLAY

Use the menu display in order to:

• View information from the heat pump.
• View available menus.
• Change set values.

8.5

MENU BUTTON AND MENU DIAL

Use

 to get from 

Initial menu

 to the menus. Use the menu dial in 

order to:

• Navigate the menus and get to the setting displays.

– Turn the dial to see more menus on the same level or change a set 

value.

– Press the dial to change to a lower menu level or save a change.

8.6

RETURN BUTTON

Use

to:

• Go back to the previous menu level.
• Leave a setting display without changing the set value.

8.7

MODE BUTTON

Use

to change type of operation.

8.8

INFO BUTTON

Use

to see information from the control unit about operating 

mode, temperature, program version, etc.

The lamp lights continuously.

The heat pump is running.

The lamp flashes rapidly

.

There is an alarm that has not been 
acknowledged.

The alarm has been acknowledged 
but the alarm cause remains.

The lamp flashes slowly, menu 
window not lit.

The heat pump is in stand-by mode

1)

.

1) Stand-by means that the heat pump control unit has been turned off but with 

electrical power still supplied to the unit.

The lamp and menu display not 
lit.

No voltage to the control unit.

Table 2 Lamp functions

The controller language can be changed with the 

button.

▶ Press the 

button in the initial menu for at least 5 

s, then select the required language.

Содержание 11 KW

Страница 1: ...UK IE USER MANUAL USER INSTRUCTIONS WORCESTER GREENSTORE LECP GROUND SOURCE HEAT PUMP IN EITHER SYSTEM OR COMBI VARIANTS 6 720 802 172 01 1I 6KW 7KW 9KW AND 11KW 6 720 802 172 2012 06 en...

Страница 2: ...water 15 13 4 Holiday 16 13 5 Energy measurements 16 13 6 Timers 16 13 7 External control 16 13 8 General 17 13 9 Alarms 17 13 10 Access level 18 13 11 Return to factory settings 18 14 Alarms 18 14 1...

Страница 3: ...keep the building warm Inbivalentoperationasecondheatingappliance e g gasoroilboiler is used to supplement the heat load 3 1 SELECTION AND SIZING OF A HEAT PUMP Itisessentialthatheatpumpsystemsaredes...

Страница 4: ...t water cylinders Greenstore6 11Systemareheatpumpsdesignedtobesupplemented with external domestic hot water cylinders Once the heat pump has been installed and started there are a number of points tha...

Страница 5: ...the condenser the heat is transferred to the house heating system radiators and underfloor heating and the hot water system The vapour cools and liquefies The pressure in the refrigerant is still hig...

Страница 6: ...play 8 2 ON OFF BUTTON Use the On Off button to turn the heat pump on and off 8 3 STATUS LAMP 8 4 MENU DISPLAY Use the menu display in order to View information from the heat pump View available menus...

Страница 7: ...x operating time on off Room temperature program Circuit 2 3 option Heat curve Room temperature program General Summer winter operation Hot water Extra hot water period Stop temperature Hot water pea...

Страница 8: ...t The marked row shows your position among the functions under Hot water 3 The arrow shows that there is new menu on the next level 4 The points show that the next level is a setting window 5 The func...

Страница 9: ...the initial menu Press in a menu display The detailed information is displayed for as long as is pressed Release The menu display is displayed Fig 18 11 3 OPERATING SYMBOLS Symbols for different funct...

Страница 10: ...led room controllers Inthedisplaywindow operatingsymbolscanappearatthebottomright handside ThesymbolforExtrahotwaterorHolidayisdisplayedwhen the function has been set in the heat pump The room control...

Страница 11: ...splayed only if party mode is active Holiday The same functions are included here as in the Holiday menu Chapter 13 4 Extra hot water duration For a description of setting Extra hot water Chapter 13 3...

Страница 12: ...quare is highlighted The value is then highlighted Fig 25 Turn the menu dial to change the value Press the dial to save or use to return without saving Inthewindow thesquareishighlightedagainandanycha...

Страница 13: ...the menu dial Turn the menu dial to be able to set additional values in the same way as above Go back one step with Select Saving alternative Return without saving Program 1 Program 2 The set changes...

Страница 14: ...room controller Holiday Active program External control SET POINT VALUE CALCULATION The set point value for the heating circuit is the current curve value adjusted with active curve influence if any s...

Страница 15: ...the day on which the hot water peak should take place None means that the function is disabled All means that a hot water peak takes place every day If hotwater peakisdeactivated comfortmodemustbesele...

Страница 16: ...This displays Generated energy in kWh divided into Heating and Hot water Consumption electric additional heat ThisdisplaysConsumptionelectricadditionalheatinkWhdividedinto Heating and Hot water 13 6...

Страница 17: ...played in the top left corner of the display If the alarm is active the alarm symbol Chapter 11 3 is displayed both in the alarm log and the initial menu of the control panel Delete alarm log The alar...

Страница 18: ...er on the heat pump sounds for one second peralarmbuzzerintervalset Atcertaintimesofthedaythealarmbuzzer can be blocked or blocked altogether In the event of a warning the alarm buzzer does not sound...

Страница 19: ...ice conditions Alarm timer starts Yes Reset condition The hot gas temperature drops to the permitted temperature Category A Alarm lamp buzzer Yes Restart Acknowledgement is required Contact your insta...

Страница 20: ...ion The value of the sensor indicates 50 C Category E Alarm lamp buzzer Yes Restart Automatic once the alarm cause has disappeared Contact your installer if the alarm remains active for more than thre...

Страница 21: ...en 14 7 19 FAILURE ON SENSOR T2 OUTDOOR Function In the event of a failure on T2 the outdoor temperature is set to 0 C so that the heat pump can continue to produce heat The alarm is activated when th...

Страница 22: ...for more than three hours or recurs often 14 7 29 FAILURE ON SENSOR E2X T10 Function Activated when the sensor s resistance value indicates a temperature lower than 20 C Reset condition The value of t...

Страница 23: ...tion The pressure goes back to the permitted level 14 9 3 TEMPORARY HEAT PUMP STOP E21 RHP Function Activated when the pressure in the refrigerant circuit becomes too high If the information appears s...

Страница 24: ...connected to the heat pump collector circuit the cold side The level in the vessel must not be less than minimum level 1 3 If the fluid level is too low contact your installer 16 3 PARTICLE FILTER Th...

Страница 25: ...6 720 802 172 2012 06 25 NOTES...

Страница 26: ...6 720 802 172 2012 06 26 NOTES...

Страница 27: ...6 720 802 172 2012 06 27 NOTES...

Страница 28: ...900 Worcester Bosch Group is a brand name of Bosch Thermotechnology Ltd worcester bosch co uk 6 720 802 172 WORCESTER BOSCH GROUP TECHNICAL SUPPORT 0844 892 4010 APPOINTMENTS 0844 892 3000 SPARES 0190...