background image

1

3

2

4

Min.

5cm

Max.

40cm

Sensitivity is adjustable by setting the 
volume on the sensor body

Sensitivity Adjustment

Toggle mode / Pulse mode

Mounting Information

The sensor can be placed behind tiles, 
wood, plaster, plastic and glass.

Do not place the sensor behind 
metallic plates.

Do not place the sensor in the opening 
range of the door.

Avoid moving objects in front of 
the sensor

5cm

40cm

Toggle mode :

 

Recommended for Switch applications. 

In toggle mode, a detection activates the relay and a
second detection deactivates it again. In door applications, 
the door stays open after the first activation.

Pulse mode :

 

Recommended for automatic door applications. 

In pulse mode, a detection activates the relay for a short 
period of time (depending on the duration of the movement in 
front of the sensor).

T

P

Min. 1s

Relay ON
Relay OFF

Relay ON
Relay OFF

DOOR OPENS

DOOR CLOSES

DOOR OPENS
AND CLOSES

DOOR OPENS
AND CLOSES

M

icrowave Touchless

Switch (MG100)

Instruction Manual 

The MG100 is a highly sensitive, high performance switch designed to activate
automatic doors by detecting the movement of a person or object. For the safe and accurate
use of this product, please read this instruction manual carefully.

Technical specifications

Technology :

     Microwave Motion Sensor

Microwave Module :

    24.125GHz 

Product Size :   

85.9mm 

ˣ

 85.9mm 

ˣ

 20mm (W 

ˣ

 L 

ˣ

 H) 

Detection Range [Hand] :

 ±5~40cm

Detection Mode :

 Motion (Bi-directional)

Speed of Target : 

Min. ±3cm/s, Max. ±1.5m/s 

Power Supply :

     DC 12~30V,  AC 12~24V

Current Consumption :

     < 1.4W

Output :

     Relay Contact (1A/24VDC)

Output Hold Time :

 1.2Sec. (PULSE mode)

Operating Temp/Humidity :

 -20°C~+50°C/0~90%

International Protection : IP55

General Information

 

Caution

Do not supply power during installation.
Do not disassemble or modify the device, it may cause fire or electric shock

Cable Hole

Screw Hole

Sensitivity Volume

Output Mode:

Toggle or Pulse

Terminal 
Block

LED

Sensing Module

Front Case

Inner Case

Waterproof Pad

Disassemble Front Case

Use a screwdriver to
remove the front case.

Installation Guide

1

 

Affix mounting template

   and drill holes

2

 

Waterproof pads are

    attached to the inner case.

3

 

Fix the case to the wall

4

 

Connect power and relay wires

    to the terminal block.

Inner Case

Waterproof Pad

POWER

COM

NC

NO

DC 12~30V 
AC 12~24V

How to remove the Clearwave cover 
after installation

1

2

1.

 Insert  flat headed screwdriver.  

2.

 Turn screwdriver gently anti-clockwise