2.5. Setting operation mode
Change the mode and option using the MODE Code.
MODE button
: use for changing OPTION status. (
Error Lamp
)
FEED button
: use for changing MODE status. (
Power Lamp
)
[Example] The defaults of the printer are :
UART / 9600 bps / 8 data bit / No parity / 1 stop bit / Density low
If a user wants to modify the defaults with
Protocol UART / 57600 bps / 7 data bit / Odd parity / 2 stop bit / Density high
Press
MODE Button
during the
Error Lamp
flicking 5 times.
You will see the
Power Lamp
and the
Error Lamp
flickers once.
Press the
MODE Button
once and the
Error Lamp
flickers twice.
And then, interface mode has set to
Protocol UART
mode.
When you press
FEED button
once again,
Power Lamp
flickers twice and
the
Error Lamp
flickers once.
Press
MODE Button
3 times,
Error Lamp
flickers 4 times.
And then, baudrate has set to
57,600 bps
.
When you
press
FEED Button
once again,
Power Lamp
flickers 3 times
and the
Error Lamp
flickers twice.
Press
MODE Button
once,
Error Lamp
flickers once.
And then Data Bit has set to
7 data bit
.
When you press
FEED Button
once again,
Power Lamp
flickers 4 times
and the
Error Lamp
flickers once.
Press
MODE Button
once,
Error Lamp
flickers twice.
And then the Parity bit has set to
Odd parity bit
.
When you press
FEED Button
once again,
Power Lamp
flickers 5 times
and
Error Lamp
flickers once.
Press
MODE Button
once,
Error Lamp
flickers twice.
And then the density has set to
2 stop bit
.
When you press
FEED Button
once again,
Power Lamp
flickers 6 times
and
Error Lamp
flickers once.
Press
MODE Button
twice,
Error Lamp
flickers 3 times.
And then the density has set to
Density high
.