WSP-i350 Rev. 4.1
20
FEED button
: changing Printer MODE status. (
Power Lamp
)
POWER button
: changing OPTION status. (
Error Lamp
)
[Example] The defaults of the printer are :
UART / 9600 bps / 8 data bit / No parity /1 stop bit / Density low /
Quality low / Mark use / Sensor High / 5 min Off
If a user wants to modify the defaults with
Bluetooth / 57,600 bps / 7 data bit / Odd parity /2 stop bit / Density high /
Quality high / Mark no use / Sensor Low / No use
Press FEED & POWER Button during the
Error Lamp
flickers 5 times.
You will see present
COMMUNICATION
mode in the LCD. (UART)
Press the
POWER Button
twice. And then, interface mode has set to
Bluetooth
mode.
When you press
FEED button
once.
You will see present
BAUD RATE
mode in the LCD. (9600 bps)
Press
POWER Button
3 times. And then,
BAUD RATE
has set to
57,600 bps
.
When you press
FEED button
once.
You will see present
DATA BIT
mode in the LCD. (8 Data bit)
Press
POWER Button
once. And then Data Bit has set to
7 DATA BIT
.
When you press
FEED button
once.
You will see present
PARITY
mode in the LCD.
(No parity)
Press
POWER Button
once. And then the Parity bit has set to
ODD Parity Bit.
.
When you press
FEED button
once.
You will see present
STOP BIT
mode in the LCD.
(1 stop bit)
Press
POWER Button
once. And then the density has set to
2 Stop bit
.
When you press
FEED button
once.
You will see present
DENSITY
mode in the LCD.
(Density low)
Press
POWER Button
twice.
And then the density has set to
Density high
.