Installation of an upstream filter is highly recommended for all applications. The
preferred TecJet 50 filter is 50 µm.
•
Install the TecJet 50 between the two flanges that are fitted onto the gas
pipe (see Figure 2-8).
•
Place a gasket between the TecJet 50 flange and the flange on the gas
pipe.
•
Connect the TecJet 50 flange to the flange on the gas pipe on both sides,
according to DIN 2501 (DN80, PN 10/16) for Europe, or to ANSI B (16,5 3”,
125/150 lb) for North America (see Figure 2-8).
•
The TecJet 50 should preferably be supported using a bracket. Use the four
screw holes (M8x16) located at the bottom of the housing to install the
TecJet 50.
NOTE
The TecJet 50 must be installed horizontally, with the electronics at the top-
side, and the connector located at the outlet side of the valve. The centerline
of the TecJet 50 should be parallel to the centerline of the crankshaft in
order to avoid severe vibration levels in the moving direction of the TecJet
50 metering piston (see Figure 2-8).