Manual 89015
Hydraulic Amplifier (Electrical Input)
Woodward
v
Regulatory Compliance
The listings in this section are limited to Hydraulic Amplifiers with EG-3P
actuators
European Compliance for CE Marking:
These listings are limited only to those units bearing the CE Marking.
ATEX
– Potentially
Directive 2014/34/EU on the harmonization of the
Explosive
laws of the Member States relating to equipment
Atmospheres
and protective systems intended for use in
Directive:
potentially explosive atmospheres.
Zone 1, Category 2, Group IIG Ex e II T4
TUV 15 ATEX 7717X
Other European and International Compliance:
Compliance with the following European Directives or standards does not qualify
this product for application of the CE Marking.
ATEX Directive:
Exempt from the non-electrical portion of the ATEX
Directive 2014/34/EU due to no potential ignition
sources per EN 13463-1:2009 Category 2.
Pressure
Compliant as “SEP” per Article 4.3 to Pressure
Equipment
Equipment Directive 2014/68/EU on the
Directive:
harmonization of the laws of the Member States
relating to the making available on the market of
pressure equipment.
Machinery
Compliant at partly completed machinery with
Directive:
Directive 2006/42/EC of the European Parliament
and the Council of 17 May 2006 on machinery.
IECEx:
Certified for use in hazardous locations IECEx TUR
15.0024X
Ex e IIC T4 Gb
North American Compliance:
UL:
UL Listed for Class I, Division 2, Groups B, C, D, T3.
For use in the United States.
UL File E158654
Special Conditions for Safe Use
The risk of electrostatic discharge is reduced by permanent
installation of the valve, proper connection of the equipotential
ground lugs, and care when cleaning. The valve should not be
cleaned unless the area is known to be non-hazardous.
Wiring must be in accordance with North American Class I, Division 2 or
European Zone 2 wiring methods as applicable, and in accordance with the
authority having jurisdiction.
Field Wiring must be suitable for at least 90 °C.
Connect ground terminal to earth ground.
Содержание EG-3P
Страница 12: ...Hydraulic Amplifier Electrical Input Manual 89015 4 Woodward Figure 1 2 5 1 4 Hydraulic Amplifier Dimensions...
Страница 13: ...Manual 89015 Hydraulic Amplifier Electrical Input Woodward 5 Figure 1 3 7 1 4 Hydraulic Amplifier Dimensions...
Страница 32: ...Hydraulic Amplifier Electrical Input Manual 89015 24 Woodward Figure 5 2 Parts for EG 3P Actuator...
Страница 38: ...Hydraulic Amplifier Electrical Input Manual 89015 30 Woodward Declarations...
Страница 39: ...Manual 89015 Hydraulic Amplifier Electrical Input Woodward 31...