8
Technical Specifications
Ambient
Items
Contents
Power Supply
Operating Voltage
8.0 V
DC
to 35.0 V
DC
, Continuous Power
Supply.
Reverse polarity protected
Maximum supply
voltage
Short Time 80 V (5-10 s)
Long Time 50 V
Minimum supply
voltage
6.5 V
Maximum operating
current
(All relays closed, LCD bright)
230 mA (12 V);
110 mA (24 V)
Maximum standby
current
(All relays closed, LCD dim)
180 mA (12 V);
90 mA (24 V)
Power Consumption
<3 W (standby ≤ 2 W)
Battery voltage measurement Accuracy
1% (12 V/24 V)
Alternator
Input Range
3-Phase 4-Wire
15 Vac – 173 Vac (ph-N) (according to
UL6200)
3-Phase 3-Wire
30 Vac – 620 Vac (ph-ph)
3-Phase 3-Wire
30 Vac – 300 Vac (ph-ph) (according to
UL6200)
Single-Phase 2-Wire
15 Vac – 173 Vac (ph-N) (according to
UL6200)
2-Phase 3-Wire
15 Vac – 173 Vac (ph-N) (according to
UL6200)
AC-
Measurement
Voltage Accuracy
(400/480 V % rated)
Phase-phase: 100 .. 624 V
:
1%; 50 .. 100 V
:
1.5 %
Phase-phase: 100 .. 300 V
:
1%; 50 .. 100 V
:
1.5 % (according to UL6200)
Phase-neutral: 100 .. 173 V
:
1% 50 .. 100 V
:
1.5 % (according to UL6200)
Minimum frequency
Generator: 10 Hz
79
easYgen-400
B37884A
8 Technical Specifications
Released