Woodward 5448-880 Скачать руководство пользователя страница 2

Manual 37338 

Replacement of GCP-10 Series with easYgen-1500 - Application Note 

 

 

 

 

WARNING

 

Read this entire manual and all other publications pertaining to the work to be performed before install-
ing, operating, or servicing this equipment. Practice all plant and safety instructions and precautions. 
Failure to follow instructions can cause personal injury and/or property damage. 
The engine, turbine, or other type of prime mover should be equipped with an overspeed (overtempera-
ture, or overpressure, where applicable) shutdown device(s), that operates totally independently of the 
prime mover control device(s) to protect against runaway or damage to the engine, turbine, or other 
type of prime mover with possible personal injury or loss of life should the mechanical-hydraulic gov-
ernor(s) or electric control(s), the actuator(s), fuel control(s), the driving mechanism(s), the linkage(s), 
or the controlled device(s) fail. 
Any unauthorized modifications to or use of this equipment outside its specified mechanical, electrical, 
or other operating limits may cause personal injury and/or property damage, including damage to the 
equipment. Any such unauthorized modifications: (i) constitute "misuse" and/or "negligence" within 
the meaning of the product warranty thereby excluding warranty coverage for any resulting damage, 
and (ii) invalidate product certifications or listings. 

 

 

CAUTION 

To prevent damage to a control system that uses an alternator or battery-charging device, make sure 
the charging device is turned off before disconnecting the battery from the system. 
Electronic controls contain static-sensitive parts. Observe the following precautions to prevent dam-
age to these parts. 

  Discharge body static before handling the control (with power to the control turned off, contact a 

grounded surface and maintain contact while handling the control). 

  Avoid all plastic, vinyl, and Styrofoam (except antistatic versions) around printed circuit boards. 

  Do not touch the components or conductors on a printed circuit board with your hands or with 

conductive devices. 

 

 

OUT-OF-DATE PUBLICATION 

This publication may have been revised or updated since this copy was produced. To verify that you 
have the latest revision, be sure to check the Woodward website: 

http://www.woodward.com/pubs/current.pdf

The revision level is shown at the bottom of the front cover after the publication number. The latest 
version of most publications is available at: 

http://www.woodward.com/publications

If your publication is not there, please contact your customer service representative to get the latest 
copy. 

 

Important definitions 

 

 

WARNING 

Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury. 

 

 

CAUTION

 

Indicates a potentially hazardous situation that, if not avoided, could result in damage to equipment.

 

 

 

NOTE 

Provides other helpful information that does not fall under the warning or caution categories.

 

 

Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be 
correct and reliable. However, Woodward assumes no responsibility unless otherwise expressly undertaken. 

 

© Woodward 

All Rights Reserved. 

 

 

Page 2/13 

© Woodward 

Содержание 5448-880

Страница 1: ...37338 Replacement of GCP 10 Series with easYgen 1500 Application Note Application Note easYgen 1500 Software Version 2 0xxx Manual 37338...

Страница 2: ...ff before disconnecting the battery from the system Electronic controls contain static sensitive parts Observe the following precautions to prevent dam age to these parts Discharge body static before...

Страница 3: ...H EASYGEN 1500 5 Technical Data 5 Functional Overview 6 Terminal Overview 6 Wiring Overview 7 Parameter Assignment 8 One Breaker Application GCP 11 8 Analog Inputs GCP 11 T2 8 CHAPTER 3 REPLACEMENT GC...

Страница 4: ...PDF IC 37321 PDF easYgen 1000 Operation Manual 37322 http www woodward com pubs download cfm link PDF IC 37322 PDF easYgen 1000 Interface Manual 37262 http www woodward com pubs download cfm link PDF...

Страница 5: ...densing Digital input 12 alarm inputs 4 to 40 VDC 7 alarm or logic inputs 6 5 to 40 VDC Digital output 9 freely configurable isolated output 24 VDC 3 freely configurable outputs common root 3 freely c...

Страница 6: ...S communication for external units or CAN Open protocol Terminal Overview GCP 11 terminals easYgen 1500 terminals comment Power supply 1 2 48 49 Generator voltage 22 23 24 0 29 27 25 23 480V 28 26 24...

Страница 7: ...92 1 36 7 22 23 24 15 58 57 55 56 14 4 G 21 20 9 8 crank Fuel solenoid GCP 11 54 53 Remote start Battery 12 24V Battery 0 VDC 37 38 41 0 42 48 52 53 51 54 9 10 49 50 29 or 28 27 or 26 25 or 24 45 6 7...

Страница 8: ...ike the GCP 11 Configuration Block Application Application mode GCB Start request in automatic DI 2 default value Show mains data NO Configuration Block Breaker GCB frequency window 10 min max range o...

Страница 9: ...igital input 12 alarm inputs 4 to 40 VDC 5 6 alarm or logic inputs 6 5 to 40 VDC Digital output 8 freely configurable isolated output 24 VDC 3 freely configurable outputs common root 1 freely configur...

Страница 10: ...l units or CAN Open protocol Terminal Overview GCP 11 terminals easYgen 1500 terminals comment Power supply 1 2 48 49 Generator voltage 22 23 24 0 29 27 25 23 480V 28 26 24 22 120V Mains voltage 50 51...

Страница 11: ...y 12 24V Battery 0 VDC 41 42 4 22 48 52 53 51 54 9 10 Sheet 2 49 50 29 or 28 27 or 26 25 or 24 19 or 18 57 56 21 or 20 15 or 14 33 32 35 Easy Gen 1500 45 44 36 37 23 or 22 58 Generator voltage 480VAC...

Страница 12: ...operate like the GCP 12 Configuration Block Application Application mode GCB MCB Start request in automatic DI 2 default value Configuration Block Breaker GCB frequency window 10 min max range of the...

Страница 13: ...29 70565 Stuttgart Germany Phone 49 0 711 789 54 0 Fax 49 0 711 789 54 100 sales stuttgart woodward com Homepage http www woodward com power Woodward has company owned plants subsidiaries and branche...

Отзывы: