The Model W1812 is wired for 220V single-phase
operation. The power supply circuit used for this machine
MUST be grounded and rated for the amperage given
below. Never replace a circuit breaker with one of higher
amperage without consulting a qualified electrician to
ensure compliance with wiring codes. This machine must
be connected to a grounded circuit!
A plug is not supplied with this machine. See below for
the recommended plug type for this machine.
@]pflXi\lejli\XYflkk_\n`i`e^Zf[\j`epfliXi\X
fipflgcXekfZfee\ZkpflidXZ_`e\kfXj_Xi\[Z`i$
Zl`k#pfldXpZi\Xk\X]`i\fiZ`iZl`kfm\icfX[_XqXi[Ç
ZfejlckXhlXc`]`\[\c\Zki`Z`Xekfi\[lZ\k_`ji`jb
.
We do not recommend using an extension cord; however,
if you have no alternative, use the following guidelines:
•
Use a cord rated for Standard Service (S).
•
Do not use an extension cord longer than 50 feet.
•
Ensure that the cord has a ground wire and pin.
•
Use the gauge size listed below as a minimum.
<ok\ej`fe:fi[j
Fg\iXk`e^MfckX^\
8dg;iXn
D`e
.
:`iZl`kJ`q\
I\Zfdd\e[\[Gcl^
<ok\ej`fe:fi[
220V Operation
12 Amps
15A
NEMA 6-15 (not incl.)
14 Gauge
=`^li\
2
. 6-15 plug and receptacle.
<c\Zki`ZXcJg\Z`]`ZXk`fej