background image

INSTALLATION

LOCATION

A stove which is centrally located will heat the greatest area of your home. Heat should be

able to circulate easily into nearby rooms. Placing your stove near an open stairway or register
in the floor will help transfer heat to other rooms. 

Other installation considerations are:

•Clearance to Combustibles
•Adequate Space for Wood Loading and Ash Removal
•Room Traffic Patterns

Most people install their stove in a room they use frequently where they can enjoy the beauty

and comfort of the stove. This also helps in the monitoring and reloading the stove as needed.
A well-planned placement will enhance your enjoyment of your stove and may save installa-
tion costs. 

It is not recommended to install a high efficiency stove in an unfinished basement. Heat loss in an unfinished base-

ment is significant, and it is common for  high efficiency stove to be overfired in order to compensate for the heat loss

through the unfinished basement walls. For a full article on Basement Installation, visit www.woodstove.com or call 1-800-
866-4344.

The best location for a chimney and
woodstove is in the center of the
house.  The chimney will be
warmer, draft will be better, and
radiant heat will be distributed
more evenly.

ALCOVE INSTALLATIONS

THE MODEL 210 IDEAL STEEL HYBRID WOODSTOVE IS NOT APPROVED FOR AN
ALCOVE INSTALLATION. AN ALCOVE IS DESCRIBED AS AN AREA LESS THAN 512
CUBIC FEET, WHICH IS EQUIVALENT TO AN 8’X8’X8’ SPACE.

1

For over two centuries, New Englanders have heated their

homes with soapstone stoves.  A properly installed and oper-
ated soapstone stove will warm your home and delight your
eye for a lifetime.

Read this entire manual carefully.

It explains how to

install your Woodstock Soapstone Ideal Steel Hybrid Wood
Stove safely and how to operate it correctly and efficiently.
The clearances and procedures recommended in this guide
are in compliance with the recommendations of the National
Fire Protection Association (NFPA), the Underwriters
Laboratories (UL), and the U. S. Environmental Protection
Agency (EPA).  You may feel some of them are very
stringent, but they should be followed.  They were designed
to protect you, your home, and the environment.  

Improper

installations are a major cause of serious fires. Failure to
follow instructions may result in property damage, bodily
injury, or death.

Before installing a woodstove, check your local building

codes and any requirements established by your insurance
company.

You may need a local building permit to install your stove.

Any changes in your home must comply with building
codes.  If the codes have not been fully updated, you may
want to check with the Building Inspection Department or

your local Fire Department.  A qualified stove installer
should be aware of any changes and updates to local and
state codes and may be best suited to handle your
installation work.

Many chimney sweeps are qualified installers.  If you are

unfamiliar with sweeps or need to locate a certified sweep in
your area, you can check listings at www.csia.org (Chimney
Safety Institute of America).  Builders and contractors are
another option.  In some cases, homeowners install their own
stoves.  Before installing your stove, please review carefully
the stove installation, clearance, and safety information in
this manual. Woodstock Soapstone has NFI (National
Fireplace Institute) certified woodburning specialists on staff
and available to answer any questions you may have about
your installation.  If you have questions, please call us toll
free at 1-800-866-4344.

You should notify your insurance company that you are

using a woodstove.  Before you light your first fire, have a
local building inspector and your insurance representative
inspect, and approve in writing, your installation.

When this room heater is not properly installed, a house
fire may result.  To reduce the risk of fire, follow the
installation instructions. Contact local building or fire
officials about restrictions and installation inspection
requirements in your area.

!

Содержание Ideal Steel Hybrid 210a

Страница 1: ...k Soapstone Company Inc 66 Airpark Road West Lebanon NH 03784 Toll Free 1 800 866 4344 www woodstove com Tested To UL 1482 2011 7th Edition Listed By PFS Corporation GEAR HEAD STOVES BY WOODSTOCK SOAP...

Страница 2: ...states Please Note Tested and Listed for US installations only LIMITED WARRANTY Your Woodstock Soapstone Stove will be carefully inspected before shipment We will replace any part which is defective i...

Страница 3: ...Ash Removal Surface Thermometer Overfiring Daily Use The Fall Away Handle Firewood CATALYTIC COMBUSTOR 19 21 How your Combustor Works Inspection Cleaning Replacement Catalytic Probe Thermometer Frequ...

Страница 4: ...l combustion byproducts and converts exhaust to water vapor and carbon dioxide The catalytic combustor burns exhaust gasses and converts them to heat which is captured inside the stove This extra heat...

Страница 5: ...ommendations of the National Fire Protection Association NFPA the Underwriters Laboratories UL and the U S Environmental Protection Agency EPA You may feel some of them are very stringent but they sho...

Страница 6: ...tion within 10 feet measured horizontal ly of the chimney You should check your local building codes for any other requirements The recommended minimum chimney height is 15 feet from the flue collar o...

Страница 7: ...place and run from the outer surface of the brick to the inner surface of the chimney See Diagram B Below C There are also UL Listed kits available that are specifically designed for passing through a...

Страница 8: ...nstallation 2 Pitched Cathedral Ceiling through the roof Determine where the stove will be placed Be sure all clearance requirements are satisfied Choose the appropriate support for your installation...

Страница 9: ...placing the stove inside the fireplace as it would make rou tine maintenance such as cleaning the combustor more difficult and much of the heat radiating off the stove would not circulate into the ro...

Страница 10: ...66 4344 or info woodstove com Over this apply 3 1 4 or greater of a decorative non combustible material such as tile slate stone or brick Use mortar or grout to set the material in place then grout th...

Страница 11: ...t A distance from corner to the front of the hearth pad C clearance from rear corner of appliance to wall rear heat shield is recommended but not required 1 414 a constant W 2 one half the appliance w...

Страница 12: ...Shield IS 256 provided by Woodstock Soapstone Co If your installation requires the use of the Approved Rear Heat Shield call 1 800 866 4344 These clearances apply to walls ceilings furniture and othe...

Страница 13: ...D Side of stove to wall 19 B Back of pipe shield to wall 6 E Side of pipe to wall 29 5 C Above pipe to ceiling 18 WITH REAR HEAT SHIELD PIPE SHIELD ATTACHED A Back of stove shield to wall 6 D Side of...

Страница 14: ...nnector Pipe C Pipe to corner 6 Double Wall Connector Pipe B 4 Corner Installation Single Wall Pipe Back Vent C C TOP VENT NO HEAT SHIELD A Stove corners to side walls 6 determines placement B Pipe to...

Страница 15: ...a lock washer over the bolt and secure with a nut Be sure that the two outside bolts are positioned in the same row Firmly tighten each bolt and nut 4 Repeat this process on the opposite side 5 Reinst...

Страница 16: ...8 for additional clearance details 2 Pipe Shield Reduces the clearance requirement for single wall connector pipe See page 8 for additional clearance details 3 Outside Air Adapter Typically required o...

Страница 17: ...mobile homes wood stoves need a way to get adequate air for complete combustion from out side the home in order to avoid the risk of depleting oxy gen in the living space Having outside air for combus...

Страница 18: ...the flue proceed with lighting the fire If the flame stands still or is pushed away from the flue exit you must establish a good draft before lighting a fire A hair dryer or heat gun pointed at the f...

Страница 19: ...moke from spilling back into the room The Ideal Steel is equipped with a smoke flap which drops down when the loading door opens The smoke flap will help keep smoke from spilling out of the loading do...

Страница 20: ...tip the andirons forward Move the hot coals to one side or the back of the firebox Scoop out the ashes that were underneath the coals and then reverse the procedure Leave some ash and hot coals in the...

Страница 21: ...h temperatures in this range can lead to metal warping becoming brittle and eventually deteriorating completely It can shorten the useful life of the catalytic combustor Avoid overfiring by letting th...

Страница 22: ...dwoods as compared to green freshly cut hard woods It is perfectly fine to burn soft woods in your stove as long as they are properly dried Hardwoods are preferable because they are typically denser t...

Страница 23: ...uring long burning times hence the need for a catalytic combustor Your catalytic combustor can get the most efficiency out of every piece of wood if it has three things temperature turbulence and time...

Страница 24: ...fly ash from the combustor Inspect the gasket that the combustor housing rests against 3 Return the combustor to the stove Be sure that it is seated properly Place the radiator over the combustor Rais...

Страница 25: ...sh If this is the case follow the cleaning procedure described in detail on page 20 of this manual Q Is it all right to burn my stove hot daily to clean any build up in my chimney system A It is not n...

Страница 26: ...of the glass or wipe off fly ash we recommend that you use a brush with soft bristles like a paintbrush A white vinegar and water solution works well to remove most ash or soot accumulation You may cl...

Страница 27: ...ctor and the chimney Wet or green wood can also produce dense smoke and excessive water vapor which can quickly lead to creosote buildup Creosote will accumulate faster in exterior chimneys than inter...

Страница 28: ...stovepipe for blockage and creosote accumulations Check spark arrestor screen on your cap if you have one Check the outside inlet for blockage caused by snow debris or insects Reline chimney to appro...

Страница 29: ...ppear Run a hot fire to burn smoke off the glass or remove build up with glass cleaner when stove is cold Green or wet wood Burn dry wood or open air damper slightly for a hotter burn see above Is my...

Страница 30: ...ation are often to blame Follow the guidelines in the Installation chapter of this manual with regard to Proper chimney and connector pipe Clearances to combustible surfaces and objects Floor protecti...

Страница 31: ...an and replace as necessary The chimney or chimney pipe should be cleaned and checked by a certified specialist once a year A small mirror held at the cleanout door of a masonry chimney will be helpfu...

Страница 32: ...MODEL 210 VIEWS Top View Front View Side View Back View Bottom View Cut Away MODEL 210 IDEAL STEEL HYBRID 28...

Страница 33: ...Bypass Rod Assembly PG 11 Door Assembly PG 121 Ash Lip Sub Assembly PG 918 Radiator PG 22 Bypass Rod Assembly PG 11 Door Assembly PG 121 Ash Lip Sub Assembly PG 18 Andiron Assembly PG 930 Air Jet Tub...

Страница 34: ...wn with PG 109 Lever PG 311 Tertiary Rear Cover PG 23 Tertiary Inlet Assembly PG 21 Upper Top Assembly PG 17 Top Lid Assembly PG 119 C Channel Leg Support 2 PG 14 Leg H Weldment 2 PG 23 Tertiary Inlet...

Страница 35: ...ORATIVE ACCESSORIES ATTACHMENTS PG 18 Andiron Assembly PG 29 Side Shelf PG 802 Center Burner PG 803 Outside Burner PG 305 Fender UB 204A Soapstone Insert UB 801 Medallion MODEL 210 IDEAL STEEL HYBRID...

Страница 36: ...Brick 4 5 x 4 2 PG 26 E Soapstone Brick 4 5 x 2 5 5 PG 27 F Soapstone Brick 2 5 x 2 5 1 PG 27 G Soapstone Brick 1 75 x 9 4 W 2000 Firebrick 4 5 x9 10 PG 26 SOAPSTONE LINER and W 2000 FIREBRICK BASE M...

Страница 37: ...6 5 2 W 2000 B Firebrick 4 5 x 5 25 2 W 2000 C Firebrick 4 5 x 4 2 W 2000 D Firebrick 4 5 x 2 5 5 W 2000 E Firebrick 2 5 x 2 5 1 W 2000 F Firebrick 1 75 x 9 4 MODEL 210 IDEAL STEEL HYBRID 33 2000 200...

Страница 38: ...GRATE and W 2000 FIREBRICK BASE MODEL 210 IDEAL STEEL HYBRID 2000 2000 2000 2000 G G G G F F PG 981 Ash Grate W 2000 Firebrick Back 4 5 x 9 4 W 2000 F Firebrick 1 75 x 9 2 W 2000 G Firebrick 2 125 x...

Страница 39: ...EL PENTAGON SPACER 2 PG 11 DOOR ASSEMBLY PG 206 STEEL DOOR FRAME 1 PG 117 130925 STEEL DOOR HANDLE 1 PG 303 1 131023 STEEL DOOR GLASS RETAINER 1 PG 118 131107 STEEL DOOR LATCH 1 PG 933 140113 GLASS HI...

Страница 40: ...ad Door 0 750 Rope Gasket for Ash Pan Door 0 500 Rope Gasket for Top Lid Assembly 0 250 Rope Gasket for Glass in Door 0 625 Graphite Tape Gasket for Flue Collar Block off 0 75 Flat Adhesive Gasket cut...

Страница 41: ...EPA Efficiency 82 79 LHV EPA Efficiency 76 94 HHV Area Heated up to 2 200 sq ft Burn Time 10 14 hrs Heat Output Range 9 324 33 263 BTU hr Loading Door Front Loading Door Opening HxW 12 x17 Back Cleara...

Страница 42: ...GEAR HEAD STOVES BY WOODSTOCK SOAPSTONE COMPANY...

Отзывы: