Rev 10.1/8-20
16
PF-89DCO-DVS: #35132
T
O
R
ELEASE THE
P
ADS FROM THE
L
OAD
WARNING: Load must be fully supported before releasing vacuum pads.
When the load is at rest and fully
supported, pinch the valve release lever
against the valve handle, to unlatch the
handle. Then push the valve handle
inward to the “release” ( ) position
(power off), as shown. Do not attempt to
move the lifter until the vacuum pads
disengage completely from the load.
A
FTER
U
SING THE
L
IFTER
Leave the valve handle in the “release” ( ) position (power off).
CAUTION: Do not set the lifter against any surfaces which could soil or damage the
vacuum pads.
Built-in parking feet can be used to support an unloaded lifter when not suspended from a crane:
Make sure the pad frame is oriented vertically with the parking feet at the bottom. Use the
hoisting equipment to gently lower the lifter until the parking feet support its entire weight.
Make sure the lifter leans securely against an appropriate support; then detach the hoisting
equipment hook from the lift bail.
If the lifter is transported to another location, use the original shipping container and secure the
lifter so as to protect the vacuum pads and all other components from damage while in transit.
Storing the Lifter
Use the covers supplied to keep the vacuum pads clean.
!!‒CE‒!! In accordance with CE Standard EN 13155, the lifter is designed to rest on relatively
horizontal surfaces without tipping over. To store the lifter in this way, set the lifter with the
pads facing downward on a clean, smooth, flat surface. Then lower the lift bar to a horizontal
orientation and place a support under the lift bail.
Charge the battery completely when placing it in storage and at six-month intervals thereafter
(see MAINTENANCE: B
ATTERY
R
ECHARGE
). After charging the battery, disconnect the electrical
connectors uniting the battery to the battery charger and to the vacuum generating system, in
order to minimize power drainage. Preferred temperatures for storing the battery are 32° to
70° Fahrenheit [0° to 21° Celsius]. Higher temperatures require the battery to be charged more
frequently. Storage at temperatures above 100° Fahrenheit [38° Celsius] should be avoided.
TO RELEASE