Rev 26.0/6-13
18
P1-DC: #35111
• Keep a written record of all Periodic Inspections.
If any deficiency is detected during the inspection, correct it before using the lifter. If necessary,
return the lifter to Powr-Grip or an authorized dealer for repair (see LIMITED WARRANTY).
Infrequent Use
If a lifter is used less than 1 day in a 2-week period, perform the Periodic Inspection
each time
before using the lifter.
T
ESTING
S
CHEDULE
Perform these tests when placing the lifter in service
initially and each time following a repair or
modification. Correct any deficiency and retest before using the lifter.
Operational Tests
• Perform the V
ACUUM
T
EST
to follow.
• Test all features and functions of the lifter (see OPERATING FEATURES, OPERATION and
MAINTENANCE).
Load Test
Prove that the lifter can lift 100% of its Maximum Load Capacity (see SPECIFICATIONS), using an
actual load or an equivalent simulation.
8
Employ the following method to test with an actual
load:
1) Place a test load with appropriate L
OAD
C
HARACTERISTICS
(see INTENDED USE) on a stable
support. Make sure the load is oriented in the upright position.
9
2) Apply the vacuum pads to the load as previously directed.
3) After the vacuum pump stops running, disconnect the electrical connector uniting the battery
with the vacuum generating system.
Note: After the test is completed, move the valve handle to the “RELEASE” position (power
off) before reconnecting the battery.
4) Raise the load a minimal distance, to assure that it is supported by the lifter.
5) Hold the load for 5 minutes. The load must not slip or fall during this time period. If it does,
conduct a V
ACUUM
T
EST
and inspect each vacuum pad as indicated under V
ACUUM
P
AD
M
AINTENANCE
: Inspection (see sections to follow). Correct any deficiency that is found and
retest the lifter.
Note: See MAINTENANCE topics to follow for additional directions about inspecting and testing
specific lifter components. Since the low vacuum warning buzzer is controlled by a vacuum
switch, consult the V
ACUUM
S
WITCH
A
DJUSTMENT
discussion for inspection, testing and adjustment
procedures.
8
ASME Standard B30.20 requires the lifter to be tested to 125% of its Load Capacity.
9
Flat Lifters are exempt from this requirement.
Содержание P11004DC
Страница 2: ......
Страница 32: ...Rev 26 0 6 13 30 P1 DC 35111 ...
Страница 33: ...Rev 26 0 6 13 31 P1 DC 35111 ...
Страница 34: ...Rev 26 0 6 13 32 P1 DC 35111 ...