Rev 4.7/4-18
3
P1-02DC: #35108
SPECIFICATIONS
Description:
Designed for use with a crane or other hoisting equipment, the P1-02DC lifter employs
vacuum to hold a load for lifting, and it provides manual 180° rotation and manual 90° tilt
movements for load manipulation.
Model Number:
P11002DC
P1HV1102DC
P11102DC
Vacuum Pads:
1
(two, standard rubber, with #60 filter screen)
10" [25 cm] nom. diameter,
concave (Model G0750)
10" [25 cm] nom. diameter,
lipped (Model HV11)
11" [28 cm] nom. diameter,
lipped (Model G3370)
Maximum Pad Spread:
(to outer edges)
23" x 10"
[585 mm x 254 mm]
24" x 11"
[610 mm x 279 mm]
25" x 12"
[635 mm x 305 mm]
Load Capacity:
(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces
2
)
Per-Pad:
150 lbs [68 kg]
150 lbs [68 kg]
175 lbs [80 kg]
Maximum:
300 lbs [135 kg]
300 lbs [135 kg]
350 lbs [160 kg]
Lifter Weight:
80 lbs [37 kg]
Power Source:
12 volts DC, 10 amps (with Thomas pump) or 3.5 amps (with Dynaflo pump)
Battery Capacity:
7 amp-hours
Rotation Capability:
Manual, 180°, with automatic locking at each ¼ revolution (when desired)
Tilt Capability:
Manual, 90°, with automatic locking in vertical position
Vacuum Pump:
Diaphragm type, 1 SCFM [28 liters/minute] nominal airflow
Dual Vacuum System:
Two vacuum system circuits allow the lifter to maintain the vacuum level in one circuit even
if an unexpected vacuum loss occurs in the other one (eg, due to load breakage).
Vacuum Reserve Tanks:
Two vacuum reservoirs help prevent immediate vacuum loss in case of power failure and
extend battery life by reducing pump cycles required to maintain vacuum.
Vacuum Gauges:
Two dial gauges indicate current vacuum level in positive inches of Hg and negative kPa.
Low Vacuum Warning Light: Red light is energized until vacuum level is sufficient to lift maximum load weight (higher
than 16" Hg [-54 kPa]) and whenever vacuum loss causes pump to re-engage.
Low Vacuum Warning Buzzer: Maximum Alarm Volume = 103 dBA at 2 ft [60 cm]. While the lifter is powered up, an
audible alarm warns the operator whenever vacuum is not sufficient for lifting the maximum
load weight.
Options:
See separate instructions about optional features.
Operating Elevation:
Maximum = 6000' [1828 m]
Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:
This lifter is designed to have a service life of at least 20,000 lifting cycles, when used and
maintained as intended. Vacuum pads, filter elements and other wear-out items are
excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more information. For
the D
ISPOSAL OF THE
L
IFTER
after its service life, see INTENDED USE.
ASME Standard BTH-1:
Design Category "B", Service Class "0" (see www.wpg.com for more information)
!!‒CE‒!! Note: This symbol appears in the
INSTRUCTIONS
manual only when requirements of a CE Standard are
different
from requirements of other standards that also apply to this vacuum lifter. CE requirements are
mandatory in geographical areas where CE Standards apply, but may be optional in other locations.
1
Available with alternative rubber compounds for special applications (see REPLACEMENT PARTS LIST).
2
Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction Coefficient for
additional information.