2. CONTROL PANEL OVERVIEW
The standard control orders of WP-200AP dehumidifiers have been set well before delivery if no special require-
ments from customers. The WP-200AP is easy to operate. Before operation, please read the technical manuals
and other related equipment information.
Warning! Please read this Manual carefully before using the machine, the manufacturer and seller won’t bear the loss
caused by wrong operation
Warning! If the electronic control system fails, please turn off the power immediately, and carry out the general inspec-
tion and maintenance. Never arbitrarily modify the circuit and related settings before the cause is found out. Other the
manufacturer or seller won’t bear the loss.
2.1 Control panel
Timer: showing the cumulative working time
Ammeter: Showing the current of the reactivation heater
Humidometer: The humidometer has three buttons; “mode”, “down” and “up”
Power switch:
O: Off mode; —- 1 = Manual (MAN) working model, 2 = Automatic (AUT) working mode
MAN: The unit will run continuously until it is turned off.
AUT (Automatic running): The unit will run until set humidity level is reached and then shut off. When the ambi-
ent humidity rises above set humidity level, the machine will automatically restart.
Be careful! When switched on (MAN or AUT position), the blowers, wheel and heater will run simultaneously, the amme-
ter will show the current of reactivation heater while it becomes stable, in addition, the timer will begin to accumulate
the total cumulative working time.
When set in MAN position, the dehumidifiers fan wheel and heater will run continuously. No controls can be set
by the user. When set in AUT position, the desired humidty level must be set through the control panel. Switch
OFF, all parts will stop working.
2.2 Set steps:
While the machine is on “MAN working mode”, the humidometer light is off, user can not set it either, and the
machine will keep working continuously in the area until shut off.
While the machine is in “Auto working mode”, the humidometer light is on, it will show the current RH level, and
is set as below:
A:Press the “mode” button one time to enter the setting mode, press “down” or “up” until the humidometer shows the
desired RH level. The setting range is 1%-99%;
B:Press the “mode” button a second time, the humidometer will show the current RH level again;
C: Press the “mode” button a third time, the setting work is finished.
During the setting process, the power must be on