background image

GB

6

Operating Instructions

PROBLEM

CAUSE

SOLUTION

Dehumidifier does not work

The power is not connected

-  Check that dehumidifier is connected to electricity and that fuse has not gone
-  Check that the water reservoir is empty and correctly placed in the dehumidifier. 

Does not dehumidify

-The water container is full.

-The water container has not
been replaced correctly.

-The air filter is clogged.
The temperature or relative
humidity in the room where 
the device is operatingis too low.

-       Remove the water from the container. 

-       Place the water container in the correct position.

-       Clean the air filter.

-  Check that air can flow freely through the dehumidifier. Front grid and air filter should be clean and dehumidifier should stand  

20-30cm from wall

-  Check that a thick coating of ice has not formed on the cooling coils.

The dehumidifier works, but 
reduces the relative huidity 
insufficiently.

-The room is too large.

-There are too many sources 
of humidity.

-There is too much ventilation.

-        We recommend using a dehumidifier with a greater capacity.

-       We recommende using a dehumidifier with a greater capacity. 

-        Reduce ventilation (e.g close windows and shut doors.)

If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier

MDK21

MDK26

Max. working area

 70m

2

 120m

2

Air flow step 1

132m3/h

 134m

3

/h

Air flow step 2

170m3/h

174m

3

/hour

Dehumidifying at 30˚C and 80% r.h.

20 l/24h

25l/24h

Power at 30˚C and 80% r.h.

240 W

260 W

Tank volume

4 liters

4 litres

Refrigerant

R290 (70g)

R290 (75g)

Voltage

230 V

230 V

Frequency

50 Hz

50 Hz

Currentt

1,15 A

1,2 A

IP Code

IPX1

IPX1

Dimensions in mm, L x B x Hs

346x253x596

346x253x596 

TECHNICAL DATA

*Technical changes and improvements may occur. All values are 
approximate and may vary due to external circumstances such as 
temperature, ventilation and humidity.

 

 

Air Plate

Control panel

Top cover

Front casing

Pull-out hook

Continuous drain pipe

Intake

Water tank

Window for water level

Back casing

Power cord

Содержание MDK21

Страница 1: ...EHUMIDIFIER Operating Instructions Bruksanvisningl SE Revision date 12 FEB 2019 MDK OPERATING INSTRUCTIONS FOR Get 3 years warranty Register and follow the instructions at warranty woods com MDK21 MDK26 ...

Страница 2: ......

Страница 3: ...ehold wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your us device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling ...

Страница 4: ...ironments The rating plate is located behind the water tank of the dehumidifier Keep ventilation openings clear of obstruction Do not use mechanical devices or other means to accelerate the defrosting process other than those recommended by the manufacturer The appliance shall not be stored in a room with continously operating ignition sources for example open flames an operating gas appliance or ...

Страница 5: ... end of the installation Make sure that there is access to the mains plug after the installation Do not pull the mains cable to disconnect the appliance Always pull at the mains plug Use WARNING Risk of injury burns electrical shock or fire Do not change the specification of this appliance Be careful not to cause damage to the refrigerant circuit It contains propane R290 a natural gas with a high ...

Страница 6: ...om is too large There are too many sources of humidity There is too much ventilation We recommend using a dehumidifier with a greater capacity We recommende using a dehumidifier with a greater capacity Reduce ventilation e g close windows and shut doors If none of the above works you should contact your nearest retailer for checking and possible overhaul of dehumidifier MDK21 MDK26 Max working are...

Страница 7: ...ed near radiators or other heat sources or exposed to direct sunlight as it will reduce performance It is beneficial to use a radiator or heating fan to keep the temperature above 5 C The dehumidifier should stand at least 20 30cm from a wall or other obstruction for maximum air flow Ideal is to put it in the center of the room area NOTE When placed in a shower or bathing area the dehumidifier sho...

Страница 8: ...e careful The fan motor is permanently lubricated and requires no maintenance NOTE Always disconnect the cord before cleaning HINTS Sometimes it may be useful to use a frost guard or heater fan to make sure that the temperature does not fall below 5 C For maximum dehumidifying power in a room it is recommended that the air supply from outside and from adjoining rooms is minimized close doors and v...

Страница 9: ...ce is powered on press Timer 1H 2H 4H 8H for the reservation of operating timer symbol displayed on LCD screen 6 Swing press the button to switch on off swing performance 7 Night mode children lock Press the button will enter the night mode Press the button for 3 second continuously to switch on off all the lock function of the key pads WATER FULL When tank is full device will automatically shut o...

Страница 10: ...åll produktens ventilationsöppningar fria från hinder Använd ej andra metoder för avfrostning eller rengöring än de som rekommenderas av tillverkaren Produkten ska inte förvaras i ett rum där kontinuerligt använda tändkällor finns till exempel öppen eld gasvärmare eller elektriska värmare Kylkretsen får ej punkteras eller utsättas för öppen låga Köldmediet kan vara luktlöst Spraya inte vatten elle...

Страница 11: ...llationen Dra inte i nätsladden för att koppla loss produkten från eluttaget Drag alltid i stickproppen ANVÄNDNING VARNING Risk för personskador elektriska stötar eller brand Produktens specifikation får inte ändras Iakttag försiktighet för att inte skada produkten kylkrets Produkten innehåller propan R290 ett naturligt köldmedel med låg miljöpåverkan Köldmediegasen är brandfarlig Om kylkretsen sk...

Страница 12: ...r fuktighetsnivån är högre än 35 och temperaturen i utrymmet är högre än 5 C Avfuktaren fungerar men luftfuk tigheten sänks för långsamt Rummet är för stort Det är för mycket ventilation Vi rekommenderar att du använder en avfuktare med större kapacitet Minska ventilationen stäng dörrar och fönster Om inget av ovanstående fungerar bör du kontakta närmaste återförsäljare för översyn och eventuell r...

Страница 13: ...ttag för 220 240 V men tänk på följande Avfuktaren bör inte ställas i närheten av element eller andra värmekällor och inte utsättas för direkt solljus då det sänker prestandan Man kan med fördel använda ett värmeelement eller värmefläkt för att hålla temperaturen ovan 5 C Avfuktaren ska stå minst 20 30 cm från väggen och andra hinder för att luftgenomströmningen ska vara maximal Det är idealiskt a...

Страница 14: ... att sedan komma ut torr på avfuktarens framsida Wood s avfuktare är utrustade med två fläkthastigheter Läge I ger en lägre luftgenomströmning vilket genererar i en tystare gång och en något lägre avfuktningskapacitet Läge II ger en hög luftgenomströmning med en maximal avfuktning av luften RENGÖRING OCH UNDERHÅLL Wood s avfuktare kräver rengöring för att bibehålla sin höga avfuktningskapacitet Re...

Страница 15: ...r fortare Funktionen önskad fuktighetsnivå går inte att välja i tvättstugeläge 4 Fuktighetsnivå 50 60 70 Co kontinuerlig avfuktning 5 Timer när maskinen är på tryck på Timer upprepade gånger för önskat läge 1H 2H 4H 8H 6 Swing Tryck på knappen för att starta stoppa swing funktionen 7 Nattläge barnlås Tryck på knappen för att välja nattläge håll in knappen i 3 sekunder för att stänga av eller sätta...

Страница 16: ...Wood s is marketed and distributed by TES Scandinavia AB Maskingatan 2 4 441 27 Alingsås Sweden woods se info woods se 46 317613610 ...

Отзывы: