Wood’s AC Palermo Pro 18K Скачать руководство пользователя страница 9

GB

9

Operating Instructions

WOOD’S FOR CLEAN AND HEALTHY 

INDOOR AIR

The brand Wood’s was born with the 

Wood’s family over 65 years ago in the 

Canadian city of Guelph, Ontario. This 

is where Wood’s began developing and 

manufactoring dehumidifiers in 1950. Since 

then Wood’s has helped several hundred 

thousand households to prevent damages 

from mould damp, and to breathe 

cleaner air. Our portable air conditioners 

are suitable for use in most climates, 

where capacity is good even at different 

temperatures and humidity levels. They 

are used with good results in premises that 

become hot such as livingrooms, offices 

or bedrooms. The amount of hot air that 

the air conditioner removes depends 

on the temperature, humidity level and 

placement. External weather conditions 

may also affect the performance of the air 

conditioner. 

Wood’s air conditioners are safe in 

operation and intended for continuous use 

over many years. 

HOW DOES THE AIR CONDITIONING 

UNIT WORK?

Low pressure gives cold air

The main element of the air conditioner 

is a coolant, which under low pressure is 

converted to gas. The process “creates 

cold”, which is transmitted inward, while 

keeping the warm air out.

A liquid coolant is passed through an 

expansion valve and into a pipe where the 

pressure is low.

The coolant evaporates and turns into a 

gas. The process absorbs heat from the 

surroundings and the pipe is cooled.

A fan blows the cold air into the room.

The gas is passed through a compressor, 

which increases the pressure and converts 

the gas into liquid.

In this process, heat is released, which 

is led to pipes on the opposite side and 

blown out by a fan.

A thermostat shuts off the unit when the 

indoor air is cold enough.

1. SECURITY WARNINGS

             

Flammable material. This                      

appliance  contains  R290/ 

 

   

Propane a flammable refrigerant.

               

  

Refer to this manual for               

              safety information. 

              

 Read technical manual                    

 

        

              

 Read operators manual. 

              

SAFETY INFORMATION

Before the installation and use 

of the appliance, carefully read 

the supplied instructions. The 

manufacturer is not responsible 

if an incorrect installation and 

use causes injuries and damages. 

Always keep the instructions with 

the appliance for future reference. 

Children and vulnerable people 

safety

WARNING

Risk of injury or permanent 

disability.

This appliance can be used by 

children aged  8 years and above 

and persons with reduced physical, 

sensory or mental capabilities or 

lack of experience and knowledge 

if they have been given supervision 

or instruction concerning use of 

the appliance in a safe way and 

understand the hazards involved. 

Do not let children play with the 

appliance. 

Children of less than 3 years should 

be kept away unless continuously 

supervised. 

Keep all packaging away from 

children. 

Cleaning and user maintenance 

shall not be made by children 

without supervision. 

General Safety

This appliance is intended to be 

used in household and similar 

applications such as: Family room, 

living room, staff kitchen areas in 

shops, offices and other working 

environments. The rating plate is 

located at the side or back of the 

Air Conditioner.

Keep ventilation openings clear of 

obstruction.  

Do not use mechanical devices 

or other means to accelerate the 

defrosting process, other than 

those recommended by the 

manufacturer.

The appliance shall not be stored 

in a room with operating ignition 

sources (for example: open flames, 

an operating gas appliance or an 

operation electric heater. Do not 

pierce or burn.

Be aware that refrigerants may 

not contain an odour. Do not use 

water spray and steam to clean the 

appliance. Clean the appliance with 

a moist soft cloth. Only use neutral 

detergents. Do not use abrasive 

products, abrasive cleaning pads, 

solvents or metal objects.

If the supply cord is damaged, 

it must be replaced by the 

Содержание AC Palermo Pro 18K

Страница 1: ...NSTRUCTIONS FOR AC Palermo Pro 18K Manual WAC1810G Operating Instructions GB Betjeningsvejledning DK Manual de instrucciones ES Lieto anas instrukcija LV Bedienungsanleitung DE Instrukcja obs ugi PL B...

Страница 2: ...ntacting our Authorised Service Centre ensure that you have the following data available Model number receipt and serial number The refrigerant used in portable air conditioner is the environmentally...

Страница 3: ...ING INSTRUCTIONS English Swedish Norwegian Danish German French Spanish Dutch Polish Romanian Finnish Lithuanian Latvian Estonian Greek Icelandic 12 19 20 27 28 35 36 43 44 51 52 59 60 67 68 75 76 83...

Страница 4: ...GB 4 Operating Instructions A B 1 6 2 3 4 5...

Страница 5: ...GB 5 Operating Instructions D C PRODUCT DESCRIPTION 5 2 1 3 4 5 6...

Страница 6: ...GB 6 Operating Instructions PRODUCT DESCRIPTION E F G 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17...

Страница 7: ...GB 7 Operating Instructions PRODUCT DESCRIPTION H I J...

Страница 8: ...GB 8 Operating Instructions PRODUCT DESCRIPTION K L M...

Страница 9: ...a flammable refrigerant Refer to this manual for safety information Read technical manual Read operators manual SAFETY INFORMATION Before the installation and use of the appliance carefully read the s...

Страница 10: ...t Do not use multi plug adapters and extension cables Make sure not to cause damage to the electrical components e g mains plug mains cable Contact the Authorised Service Centre or an electrician to c...

Страница 11: ...conditioner must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room The effectiveness of the air Conditioner depends on the temperature...

Страница 12: ...or claning H 1 Twist both ends of the exhaust hose into the Hose Connector I 1 Drain Plug K 1 Introduction to Exhaust Hose Installation L 1 Make sure that there is no kinks in the exhaust hose M 1 Lif...

Страница 13: ...nit from any electric supply outlet 2 Do not use gasoline or other chemicals to clean the unit 3 Do not wash the unit directly 4 If the conditioner is damaged please contact the dealer or repair shop...

Страница 14: ...ct the drain hose to the bottom drain hole the unit can also work well If splash motor is damaged intermittent drainage can also be used Under this condition when the water full indicator lights up pl...

Страница 15: ...he exhaust air hose Temperature setting is too high Reset the temperature Air inlet is blocked Clean the air inlet High noise level The ground is not level or not flat enough Place the unit on a flat...

Страница 16: ...w 950 m3 h 950 m3 h Energy class A A Dehumidification 60 L 24h 64 8 L 24h Temperature setting 17 30 C 17 30 C Working temperatur 16 43 C 16 43 C EER 2 6 2 6 Drain Hose Length 1 0 m 1 0 m Hose Diameter...

Отзывы: