background image

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

www.woodbridgebath.com

5

R

WOODBRIDGE 

MODERN ONE PIECE TOILET 

CONNECT TOILET'S TANK

TO WATER SUPPLY LINE

Connect the water supply line between the tank and water 
shut-off valve using a toilet hose (not supplied). When 
connecting toilet hose tighten coupling nut to the tank by 
1/4 turn beyond the hand tight.

Turn on valve on water supply line and allow tank to fill. 
Check all connections for leakages and tighten as needed.

Once tank is filled with water flush it 4-5 times to perform 
a test of the flushing system. At the same time check the 
bottom of the toilet for leaks to make sure that the wax 
ring is properly installed and sealed.

If there are no leaks you are ready finalize the installion. If 
any shims are installed at the bottom of the toilet's bowl 
you may trim them. Apply silicone around base of the 
toilet's. Allow 24 hours for silicone to dry before start 
using the toilet. 

See Figure 6

Important:

 Leaks may not occur during or right after the 

installation. Make sure to check for leaks every couple 
hours first day installed and and occasionally check it 
everyday for the next week to ensure that toilet is properly 
installed and no leaks occur. If any leaks occur immediately 
shut off the water supply line valve and contact your local 
plumber to fix all leaks. 

Important:

Under no circumstances We shall not be liable for any and all incidental damages 
sustained in connection with this product

Neither manufacture, nor distributor, nor retailer is responsible for water 
damage or flood caused due to use of this product.

Under no circumstances We shall not be liable for any and all fees, cost of 
installation/reinstallation/removal, subsequent damage or transportation in case 
of the product defect

Figure 6

INSTALL NEW TOILET

Step 1. 

Lift and carefully put the toilet over the closet 

flange so the closet bolts can go through the mounting 
holes in the toilet's base. Once the bowl is in the position 
press the bowl down with slight twisting motion in level 
position towards the floor. Apply your body weight to 
evenly compress the wax ring to create watertight seal. 
Make sure that the bowl is as leveled as possible to have a 
nice seal tight.

Do not rock the toilet back and forth and side to side as it 
may and will break a seal and you will need to replace the 
wax ring again and start the installation process over.

See Figure 4

Step 2. 

Once the toilet is set and leveled install washers 

and nuts over the closet bolts. Tighten nuts. Do not 
overtighten the nuts. It may and will cause damage to the 
toilet's ceramic base.

See Figure 5

Do not overtighten nut on the tank connection. 
It may and will cause water leakage.

CAUTION!

2 PEOPLE ARE REQUIRED TO LIFT AND DURING
ENTIRE INSTALLATION OF THIS PRODUCT

Note: It may be required to use shims under 
the edge of the toilet's bowl. Due to 
manufacturing process of vitreous china 
ceramic products, every toilet may have 
slight level variations. It does not mean that 
the toilet is defective. In addition your floor 
might be uneven or not leveled as well.

  bolt cap 
decoration

Figure 5

Figure 4

2

1

3

Plastic washer 

W

all

Floor

12"

Rough-in

Standard

W

all

Floor

Содержание B0910

Страница 1: ...45 5 IAPMO Z124 2017 Plastic Plumbing Fixtures Compliance with the following codes standard PREFERED EDUCATION PROVIDER LISTED TM ICC SCC Accredited CB P S OCPS Accr dit CCN ANSI ACCREDITED ISO IEC 17...

Страница 2: ...NS MUST BE OBSERVED FOR SAFE INSTALLATION We reserves the right to change update modify alter redesign this manual product or its policies without prior notice We shall not be liable for any injuries...

Страница 3: ...t notice Pls measure toilet on site before installation Please note that installer s must be certify or warranty will be voided Measurements herein supersede all others published prior to purblication...

Страница 4: ...hed prior to purblication date shown below Back View Flush GPF amount is factory set No additional adjustment is required Tank Top View Inside Half Flush 1GPF Adjust the water level in the toilet s ta...

Страница 5: ...the closet bolts through the holes and align bolts horizontaly See Figure 2 Figure 3 INSTALL WAX RING Important safety glasses must be worn by the installer and all bystanders Cover the floor with a s...

Страница 6: ...ler is responsible for water damage or flood caused due to use of this product Under no circumstances We shall not be liable for any and all fees cost of installation reinstallation removal subsequent...

Страница 7: ...hinges Clip on the toilet seat and cover Clip on the toilet seat and cover Aligh the toilet seat and cover with ceramic Take off the toilet seat and cover by pressing both pushbuttons Insert the hing...

Страница 8: ...tton and lock the nut to make it well fixed in the tank The distance between the rod tail and valve push button must be 1 2mm Rotate the valve clockwise to adjust its position inside of the toilet s t...

Страница 9: ...ume will gradually increase when the adjuster is moved upward from the bottom 1 PREPARATION 2 WATER LEVEL ADJUSTMENT Press and unscrew Solution 1 Pull upwards press down to desired height Unscrew cloc...

Страница 10: ...ged due to dirty water 4 Improper refill hose installation 1 Turn on inlet valve switch 2 Adjust inlet valve position 3 Clean the filter screen 4 Install refill hose correctly see diagram on the right...

Страница 11: ...dbridgebath com R WOODBRIDGE 10 NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFO...

Страница 12: ...t of This warranty does not extend to plumbing or components installed by dealers installers or by any party other R WOODBRIDGE R WOODBRIDGE R WOODBRIDGE LIMITATIONS AND EXCLUSIONS will not be liable...

Отзывы: