Cascade Gas-Fired Rotisserie & Charbroiler
Installation and Operation Manual
20
An ongoing program of product improvement may require us to change
specifications without notice.
WS-GFR-MB, Revised November 2014.
Doc no: M0050.01
or visit
woodstone-corp.com
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
tf. 800.988.8103
t. 360.650.1111
f. 360.650.1166
PREVENTIVE MAINTENANCE
Contact the Wood Stone Service Department or a qualified local service company for any maintenance or repairs.
NOTE:
ALWAYS DISCONNECT POWER SUPPLY BEFORE SERVICING THIS APPLIANCE.
MAIN BEARING LUBRICATION (EVERY 12 MONTHS)
The two main shaft bearings should receive one pump of a NLGI Grade 2 lithium-based grease, such as Lubriplate 630-2, every
12 months� These bearings are located inside the cabinet on either end of the main shaft� A Zerk fitting for each bearing is located
directly below the top door hinge on either side of the cabinet on the operator (door) side� Care should be taken not to over lubricate
these bearings� One pump is sufficient�
MOTOR BRUSHES REPLACEMENT (APPROXIMATELY EVERY 3 YEARS)
The three year replacement recommendation is based upon an average daily use of 10 hours� Contact the Wood Stone Service
Department or your local service technician for service�
REDUCTION GEAR LUBRICATION
The gearbox is permanently lubricated and requires no additional maintenance�
SPUR GEAR BUSHING
Check the spur gear bushings for signs of binding or lateral movement where the gear shank passes through the drive end drum�
The gear should rotate in the Rulon inner bushing� If the gear and Rulon bushing are rotating in the drum sleeve instead, remove
the gears and Rulon bushings, clean and refit� Do not lubricate the bushings or gears� To remove the gears, first mark the drum in
relation to the shaft to ensure it is reinstalled in the same position� Remove the six bolts that retain the drum end to the hub and
slide the drum end assembly toward the center of the cabinet� The spur gears can now be removed by loosening the set screw
retaining the locking collar and sliding the gears out of the drum�
INNER DRUM SEALING
The condition of the high-temperature sealant used to seal the inner drums to the cabinet walls and the inside corners of the
cabinet should be checked and renewed if sealant has failed� Use Dow Corning 732 RTV sealant�
DOOR JAMB MICRO SWITCH
Check the jamb switch for proper operation� The switch should move freely in the jamb without sticking or binding and the drums
should stop when the doors are opened�
SPEED CONTROL KNOB
Check the speed control potentiometer for proper operation and the knob for tightness�
DOOR LATCH
Check the door latch mechanism for proper operation� If sticking occurs, remove the wedge pin, clean, refit and adjust�
EXHAUST HOOD
Refer to the exhaust hood manufacturer’s recommendations for inspection, maintenance and cleaning�
PREVENTIVE MAINTENANCE