OPERATION SEQUENCE - W-IR
BURNER OPERATION SEQUENCES
W-IR MODELS (OVENS WITH INFRARED BURNER (IR) ONLY)
Power On
Controller reads floor temperature
from Thermocouple�
Floor temperature below Hearth
Set Point- Controller sends power
to SV-1 Valve- SV-1 powers
Igniter and opens Pilot Valve�
Pilot does not light- SV1 times
out- Controller will flash “chec”�
Pilot lights- SV-1 senses Pilot
flame- Igniter off�
SV-1 opens, Infrared Burner
lights- Hearth heat light comes
ON�
Floor reaches Hearth Set Point-
Controller turns off power to SV-1
to turn off Burner�
Floor Temperature above Hearth
Set Point- No action�