background image

 

2

1. Introduction 

 
 
 
 

 
This detector operates on the principle of a balanced induction bridge. Under the 

influence of  metal, within the scanning field of the sensor, an amplitude–phase shift occurs 
between two low frequency sinusoidal signals (VLF).  The change in amplitude-phase shift, 
after adequate processing, activates optic and acoustic alarms.  
The Wood-Mizer Kornik ES-1 detector has: 

-

 

automatic elimination of background radiation, 

-

 

gain control, 

-

 

volume control, 

-

 

RESET button – to eliminate the influence of the soil and surroundings.  

 
This detector is the best and the most cost-effective device with such excellent parameters 

available on the market. The main advantages of this type of device in relation to other types 
of detectors (e.g. Pulse induction, BFO, transmitter-receiver) include: 

-

 

power supply from batteries or rechargeable batteries,  

-

 

current consumption during operation - max. 150 mA, 

-

 

automatic elimination of the influence of background radiation on operation of the 
device, 

-

 

concentric penetrating probe with 

 200 mm, 

-

 

the ability to automatically return to the balanced state of the detector (correction of  
the drift). 

 

 

                        

 

                                          

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Wood-Mizer 

®

 

 

Содержание KORNIK ES-1

Страница 1: ...User Guide Wood Mizer Metal Detector KORNIK ES 1 Part number MD ES1 Wood Mizer...

Страница 2: ...1 Contents 1 Introduction 2 2 Technical data 3 3 Description of the control panel 4 4 Preparing the detector for operation 5 4 1 Initial settings 5 5 Final remarks 8 Wood Mizer...

Страница 3: ...button to eliminate the influence of the soil and surroundings This detector is the best and the most cost effective device with such excellent parameters available on the market The main advantages o...

Страница 4: ...5 kg Adjustable extension arm Made from ABS plastic FUNCTIONALITY OF THE DETECTOR Gain control Background radiation control Induction threshold control Detection level signalling Supply status signal...

Страница 5: ...itch and volume control 2 Battery status indicator If the detector is ready for operation the LED glows green and if the batteries must be charged the LED glows red 3 Detection level indicator 4 Gain...

Страница 6: ...arm of the detector probe Extending the probe support First step the metal part of the arm with the handle should be turned counterclockwise which will result in the release of the torsion clamp Seco...

Страница 7: ...Gain Control as required 6 Position sensor in the air far from any metal source 7 Press the Reset button Wood Mizer Measuring smaller logs or cants turn the Gain Control to the middle position as show...

Страница 8: ...below the surface of the log or cant to be measured remember that the minimum distance from large metal objects such as bed rails is circa 250mm 9 Turn the Gain Control down until the alarm stops 10...

Страница 9: ...remember that when the gain is adjusted you must press Reset button Attention The electronic parts are not waterproof avoid for long exposure to rain or water The detector probe is not waterproof and...

Отзывы: