Accuset Troubleshooting
Accuset Display Problems
Accuset Troubleshooting
60AS-R02doc032519
2-4
2
2.2
Accuset Display Problems
If the Accuset display has no backlight when its control box is powered, check the power
light.
See Figure 2-1.
The rear of the Accuset front panel located in the control box is shown
below. The power control panel located in the power box contains the same set of lights.
To check the power light, remove the eight screws securing the Accuset front panel.
Remove the front panel from its original location without disconnecting the wires. Turn the
key switch to the on (#1) or accessory (#3) position. To check the power light located at
the power control panel, open the power box door.
If the power light is on
, replace the control panel.
If the power light is off
, check up/down circuit breaker located in the power box. Reset
the breaker if necessary. If the circuit breaker works fine, check the power control panel in
the power box, and the control panel in the operator’s control box.
DC Sawmill Only:
See
if the MOSFET panel works properly. Perform the MOSFET test as needed. If all the pan-
els are okay, wiggle the wire connections at the power box. Call Customer Service for
assistance, if the power light does not turn on.
2.2.1 Control Panel Replacement
Control box:
1.
Turn the key switch to the off (#0) position and remove the key.
2.
Remove the eight screws holding the control panel to the Accuset control box.
FIG. 2-1
SM0284
Power Light
Accuset Front Control Panel