Choosing Location
When installing your WoodMaster, keep in
mind the direction of the winds during heating
months. Try to place the boiler in an area where
exhaust will not be a problem for yourself or
any surrounding neighbors. For either indoor or
outdoor installation.
Only lift the CleanFire by the overhead hanger,
or with a fork lift from below, placing the forks
inside of the loops on the legs. NEVER LIFT THE
CLEANFIRE BY THE THROAT/FIRE CHAMBER.
THIS WILL DAMAGE THE UNIT.
Clearances
There must be a minimum clearnace from combustibe materials when the boiler is installed. There must be 6”
from either side, 48” from the front, 36” from the rear and 18” from the chimney connector. More room should be
allowed to make cleaning and maintenance easier. Keep the space underneath the boiler open. Keep the area in
front of the door clear. This space must be at least 16” in the front and 8” on either side.
For Outdoor Installation
LOCATION: It is recommended that the unit be located with due consideration to the prevailing wind direction.
• When using more that 4 feet of chimney extension external support is needed.
• Should be located greater than 100 feet from any residence not served.
• If located between 100 and 300 feet to any residence not served, it is recommended that the
stack be at least 100% of the height of the peak of the residence, plus an additional 2 feet.
• Should be located 10 feet from any combustible materials.
Always remember to comply with all applicable state and local codes.
For Indoor Installation
LOCATION: It is recommended that the unit be located with due consideration to the prevailing wind direction.
• When using more that 4 feet of chimney extension external support is needed.
Installation
Forklift
Overhead Lifting
Forks
Residence not
served by furnace
2 feet
Residence
served by furnace
Minimum of 100 feet
Chimney height
should be 2 feet above roof line