Wonderfu X565 Скачать руководство пользователя страница 5

 

 

 

Picture 2      Back View 

 

Picture 3 : Side View 

Fresh oil bottle 

 
 

Waste oil bottle 

Handle 

LP Connector 

HP Connector 

Power supply 

Содержание X565

Страница 1: ...X565 AC REFRIGERANT RECYCLING AND FLUSHING MACHINE Operation Manual ...

Страница 2: ...2 Index 1Caution 3 2Technical parameter 3 3Function 3 4Structure 4 4 1 Keypad 3 4 2 Inner Structure 7 5 Basic operation 8 6 Maintenance 45 ...

Страница 3: ...so check if the pump oil being at a modest level Otherwise please add some oil When receiving a new machine please also check scale When turn on the machine users can see the REF WEIGHT it is zero for a new machine Put 1KG weight on top of cylinder and see if the weight will increase 1KG or nearly 1KG If yes the scale is sound and good Follow strictly the operation instruction on the machine 2 Tec...

Страница 4: ...4 4 Structure Picture 1 Front View Appearance ...

Страница 5: ...5 Picture 2 Back View Picture 3 Side View Fresh oil bottle Waste oil bottle Handle LP Connector HP Connector Power supply ...

Страница 6: ... Control Pannel 1 Digital keys to set the parameter 2 Cancel key 3 Selection key 4 ON OFF key Start or Pause Key 5 Exit Low Side Gauge Cylinder pressure gauge Glass window High Side Gauge Glass window LCD Screen Operation keys ...

Страница 7: ...ture Inner structure Main board Relay vacuum Relay recovery Expansion valve Hp sensor Oil separator Storage Cylinder Hose recovery Pump Oil entry Pump Filter drier Pump Oil exit Condenser Oil drain valve Compressor ...

Страница 8: ...n machine HP connector 2 Fix the blue hose on machine LP connector 3 Connect red hose to car HP side and blue hose to LP side 4 Make sure enough space of the waste oil bottle and enough fresh oil in fresh oil bottle How to Connect to the car ...

Страница 9: ...w side adaptors See below picture twist the adaptor anti clockwise to close the quick adaptor How to open High side or Low side adaptors See below picture twist the adaptor clockwise to open the quick adaptor Close or open adaptors ...

Страница 10: ...the cylinder before operation How to refill 1 fix blue hose onto the LP connector at back of the machine and red hose onto HP Connector 2 then connect the blue hose to the external gas tank R134A 3 Close the red quick adaptor 4 Turn on the machine and choose the menu REFILL to go ahead How to refill ...

Страница 11: ...11 When everything going smoothly LCD reads ...

Страница 12: ...12 When there is refrigerant in the hose the VACUUM process will be suspended LCD reads Set the value when LCD message reads as below then press to start refilling Press to go ahead ...

Страница 13: ...13 When the REFILLING process completed press to exit ...

Страница 14: ...ng process can be suspended if you press PAUSE The refilling process can be suspended when the tank being full or at high pressure The refilling process can be suspended when there is no refrigerant in external tank ...

Страница 15: ...15 1 Switch on the machine press to choose RECOVERY then press 2 Press to continue 3 When we read the following message please follow the instruction to do vacuum RECOVERY ...

Страница 16: ...16 4 5 After vacuum press to next step 6 After setting value please press to continue ...

Страница 17: ...ess can be suspended when the storage cylinder full or pressure too high 8 The recovery process can be suspended when NOT enough refrigerant inside the A C system 9 When the recovery process is going back to normal it reads ...

Страница 18: ...18 10 ...

Страница 19: ...19 Before charging refrigerant into the A C system please vacuum the system first VACUUM ...

Страница 20: ...20 ...

Страница 21: ...21 Vacuum process can be suspended when there is refrigerant in the hose or you PAUSE it ...

Страница 22: ...22 1 Turn on choose Charge 2 Pree to next step 3 Refer to Page 8 9 on how to connect hoses and adaptor and then press to go ahead CHARGE ...

Страница 23: ...23 4 Set the charge amount then press 5 6 After charging please check if air outlet cool or not then press to go ahead CHARGE ...

Страница 24: ...4 7 Follow the instructions on the screen and press 8 The recovery process is going smoothly it reads 9 If recovering residue gas from the hose it reads as below And please follow the instruction CHARGE ...

Страница 25: ...25 10 Charge process being done and please press to exit CHARGE ...

Страница 26: ...26 1 Press to choose FLUSH then press to enter 2 press to enter 3 press to enter FLUSH ...

Страница 27: ...27 4 Vacuum before flushing 5 6 When there is gas inside the hose vaccum can be suspneded Need to recover the hose first FLUSH ...

Страница 28: ...28 7 Vacuum done 8 Set the times you need to flush and press to continue 9 The gas amount should be more than 2KG inside the tank otherwise there will be a warning FLUSH ...

Страница 29: ...29 10 When the flushing process is going smoothly it should be displaying the route of flushing 11 When gas amount too little or the valve being closed flushing will be stopped FLUSH ...

Страница 30: ... tank being full or pressure too high flushing will be stopped 13 When flushing completed it will recover the residue gas from the hose automatically 14 When tank pressure beign high recovery will be suspended FLUSH ...

Страница 31: ...31 15 16 After recovery from the hose it will drain the oil automatically 17 Flushing completed Press to go back to main menu FLUSH ...

Страница 32: ...32 1 2 3 RECYCLE ...

Страница 33: ...33 4 5 We can see the recycling route when it is going smoothly RECYCLE ...

Страница 34: ...34 6 When recycling failed this message can be displayed 6 When pressure too high 8 Recycling done press to exit ...

Страница 35: ...35 1 Flush Recovery Vacuum Charge 1 2 3 AUTOMATIC ...

Страница 36: ...36 4 Follow the instruction if you see this message 5 6 AUTOMATIC ...

Страница 37: ...37 7 Set the value 8 Set the value and press to shift to another parameter 9 AUTOMATIC ...

Страница 38: ...38 10 11 After flushing it will recover gas from the hose We can see the actual recovery amount MAINTENANCE ...

Страница 39: ...39 12 It will drain the oil after recovery 13 After recovery jump to Vacuum process 14 Jump to charge process ...

Страница 40: ...40 15 Done 2 Recovery Vacuum Charge 1 2 Press to go ahead AUTOMOTIC ...

Страница 41: ...41 3 4 5 AUTOMATIC ...

Страница 42: ...42 6 7 8 AUTOMATIC ...

Страница 43: ...43 9 10 11 AUTOMATIC ...

Страница 44: ...44 12 13 AUTOMATIC ...

Страница 45: ...45 1 Empty the internal tank When the tank being full need to charge out some gas or even empty the tank 1 2 3 Maintenance ...

Страница 46: ...46 4 Set the amount you need to discharge 5 6 If there is no space in the first tank please change a new one ...

Страница 47: ...ase exit 2 Reset data of filter The lifetime of filter is 200KG After it has recovered 190KG it will warn to change a new filter when you turn on the machine After 200KG you must change it Otherwise it will not work MAINTENANCE ...

Страница 48: ...ator 2 At the top of the filter use M16 spanner to solid the connector and M21 spanner to loose the screw anti clockwise 3 At the bottom of the filter use M16 spanner to fix M21to loose the screw clockwise 4 UseM8 adaptor to loose the screw that used to fixed the filter 5 Take out the filter from the top MAINTENANCE MAINTENANCE ...

Страница 49: ...e 8 At the bottom of the filter use M16 spanner to fix the connector and use M21 to tight the screw 9 At the top of the filter use M16 spanner to fix the connector and use M21 to tight the screw 10 After replacement please enter Maintenace and reset the data of the filter Reset the data of filter 1 ...

Страница 50: ...50 2 3 4 MAINTENANCE ...

Страница 51: ... some oil b The lifetime of pump oil is 150 Hours When you have done vacuum to 150 hours it will give warning to change the pump oil Otherwise vacuum process cannot be executed c When the pump oil color changes need to replace the oil ATTNENTION Must use the pump oil provided by the manufacturer Steps on how to change pump oil 1 Please vacuum 1 minute before changing the pump oil 2 Pump position h...

Страница 52: ...ver on top of pump 4 Get a bottle ready for the waste pump oil Use tool to loose the screw under the pump 5 After draining the oil tighten the screw 6 Use a funnel to help to fill the oil into the pump MAINTENANCE Cover ...

Страница 53: ...3 7 When filling oil make sure the oil level being correct 8 Use a tool to tighten the screw on top 9 After that reset the pump oil data Please follow below steps Reset the pump oil data 1 2 MAINTENANCE ...

Страница 54: ...54 3 4 MAINTENANCE ...

Страница 55: ...ion on the scale to ensure scale will be accurate and the tank s weight will be correct Firstly make sure the storage tank is empty or nearly empty so we can do calibration Take off the tank 1 Here is the tank position 2 Close the manual valves on top of the tank Storage tank HP manual valve LP manual valve MAINTENANCE ...

Страница 56: ... black valve out 4 Use a tool to loose the screws under the storage tank so we can take the tank out 5 Put 7kg weight onto the scale tray 6 Switch on the machine and run the process of Calibrate the electronic Scale Please follow the steps as below 1 Solenoid MAINTENANCE ...

Страница 57: ...57 2 3 Please input the password Ask for your distributor on the password 4 When you see this message please follow the instructions to take out tank then press MAINTENANCE ...

Страница 58: ...58 5 6 7 When users see below message the users must make sure the operation is 100 proper Otherwise the calibration cannot been done MAINTENANCE ...

Страница 59: ...59 8 9 When you confirm the weight being correct press to continue 10 MAINTENANCE ...

Отзывы: