![WolfPack HDTV1000TR Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/wolfpack/hdtv1000tr/hdtv1000tr_user-manual_993714006.webp)
6
Receiver Configuration
Receiver should be set IP address by DIP before working. The default IP address is
192.168.1.XXX. XXX is the DIP setting value ID.
DIP setting value ID defined as figure below:
From left to right, value of the first dip switch is 64at the upper position, 0 at the
bottom position.
The value of the second dip switch is 32 at the upper, 0 at the bottom. The rest are
done by the same mechanism. Relavant IP address can be obtained by adding up
each value.
In current system configuration, the valid IP address of receiver is between
192.168.1.1 - 192.168.1.96, which means the DIP switch should between 1
–
96.
Different devices should have different IP address, same address will cause IP
address confliction and system working abnormal.
*Notice:
Customer need video displays exceed 96 will use another set of software,
which is not described in the scope of this document.
The picture below shows an example, device ID=64+8+2+1+1=76, receiver IP
address is 192.168.1.76:
IGMP Ethernet Switch Configuration
The Ethernet switches we provided are configured before delivery. User can use it
without any software configuration.
5.
Device Management
User can access WEB to manage sender or receiver and get information.This system
also supports CGI /TCP /UDP for network control.