background image

8

WOLFEN INSTALLATION MANUAL  |  Wolfen Pre Rinse Sink Mixer 

INSTALLATION  INSTRUCTIONS 

1.  Place the base o-ring (9) on the underside of  

the mixer body (8).

2.   Screw in the hot and cold flexible connectors 

(57 & 58) to the mixer body (8).

3.  Screw in the fixing bolt (55) into the mixer body 

(8) and tighten with a screw driver.

4.  Place the mixer unit over the pre-punched  

tap hole in the sink. Feed the flexible  
connectors through first.

5.  From underneath the sink or basin, slide on  

the U-shaped fixing washer (53), then the 
U-shaped fixing plate (54). 

6.  Screw on the long hex nut (56) until the mixer  

base is firmly fixed to the sink. Tighten with a 
socket set or tube spanner.

7.   Connect the hot and cold flexible connectors 

to the inlet isolation valves. 

The unit must be 

installed with the main mixer handle to the 
side.

8.  Fit the main riser assembly into the mixer body 

by pushing the twin o-ring spigot downward, 
then fit and tighten the allen key screw (10) with 
the allen key provided (11).

 Note: the wall support bar (44) can be slid up or 
down to the desired height to enable fixing to the 
wall or splashback.

9.   Ensuring the riser is 90 degrees to the wall, 

measure and cut the wall support bar to a 
length with a 2 to 5mm gap from the wall.

10.   Slide on the chrome cover flange (45), nut (46), 

brass olive (48) & wall fixing plate (49) onto the 
wall support bar (44) as shown in exploded 
parts diagram.

11.   Fit the o-ring (47) to the groove on the fixing 

wall plate.

12.   Swing the wall support bar into position and 

mark the three holes for drilling into the wall.

13.  Swing the wall support bar to the left or right to 

enable the three holes to be drilled.

14.   For a masonry wall use the wall anchors 

provided (51) with screws (50).

15.   For a timber backed wall use the screws 

provided (50).

 Note: For a stainless steel splashback and/or cool 
room panel wall, ensure the fixing method used 
results in a solid fixing.

16.   Swing the wall support bracket back into 

position, line up the holes and screw the fixing 
plate back to the wall. Tighten the brass nut and 
olive, ensuring a firm and solid installation. Slide 
the chrome cover plate over the wall plate.

 Note: The brass MI thread on the end of the end of 
the trigger spray hose swivels, so you do not have 
to spin the whole hose around when connecting the 
hose to the riser assembly.

17.   Fit the flat washer (31) into the top of the riser 

assembly to ensure a water tight seal.

Important Note
Mixer must be installed to the requirements of AS/NZS 3500 by 
a qualified plumber. Your mixer comes to you already factory 
assembled and tested. We do not recommend the dismantling  
of any internal part of the mixer. The mixers are factory tested  
and sealed so as to give the best performance.

Installation Instructions
1.  Please flush out new pipe work prior to connecting the  

new mixer.

2.  All mixers should be installed with isolating stop cocks  

(Arco brand recommended).

3.  This tap is suitable for high pressure applications where both  

hot and cold water supply pressures are at 150kPa or above.

WOLFEN INSTALLATION MANUAL   |   Installation Instructions 

* To ensure longevity of the product we recommend Pressure reduction valves (PRV's)    
   not pressure limiting valves (PLV's) set at 350kPa working pressure (hot/cold).

Содержание Pre Rinse Sink Mixer

Страница 1: ...INSTALLATION MANUAL 252430 Wolfen Pre Rinse Sink Mixer 252452 Wolfen Compact Pre Rinse Sink Mixer 252431 Wolfen Pre Rinse Trigger Spray Installation Details Warranty TM...

Страница 2: ...Intro 03 Technical Information 04 Unit Components 06 Installation Instructions 08 Warranty 10 CONTENTS TM...

Страница 3: ...eel braided hose with external lining Wall fixing bracket for ongoing stability Installation and servicing Cut down wall bracket with height and projection adjustment Usage features Easy operation wit...

Страница 4: ...l Brass Brass Brass Cartridge Type Ceramic Disc Cartridge Ceramic Disc Cartridge N R Min Continuous Flow Working Pressure 150kPa 150kPa 150kPa Max Continuous Flow Working Pressure 450kPa 450kPa 450kPa...

Страница 5: ...inse Sink Mixer 252430 Wolfen Compact Pre Rinse Sink Mixer 252452 108 54 5 250 14 5 103 3 30 72 3 45 45 8 55 110 5 250 52 369 556 1059 284 53 620 297 250 14 5 30 53 72 3 110 103 3 45 45 8 55 110 5 150...

Страница 6: ...O Ring 4 28 81000012 Thrust Washer 2 29 81000002 Bs121 O Ring 3 No Code Description Qty 30 83060278 Riser 2 1 31 71438 8 Washer 1 32 94167 Bs019 O Ring 1 33 83060279 Support Arm 1 34 93064 Check Valu...

Страница 7: ...6 25 24 23 22 21 20 19 18 17 16 2 3 4 11 12 13 14 15 10 8 9 52 53 54 55 56 7 6 5 58 57 1 C H LOCTITE 290 LOCTITE 680 LOCTITE 680 LOCOTITE 680 40 41 42 LASER MARKING STANDARD NUMBER 16 14 B BACK 5 AS N...

Страница 8: ...or drilling into the wall 13 Swing the wall support bar to the left or right to enable the three holes to be drilled 14 For a masonry wall use the wall anchors provided 51 with screws 50 15 For a timb...

Страница 9: ...s The warranty is extended to the purchaser only and is not transferable Misuse of the product is not covered by warranty Use only suitable agents to clean the surface of your mixer i e no abrasive cl...

Страница 10: ...lowing conditions The item has been installed by a licensed plumber Failure is due to a fault in the manufacture of the product Proof of purchase including the date of purchase is provided The install...

Страница 11: ...TM IF AFTER CHECKING THE INSTALLATION INSTRUCTIONS AND IMPORTANT INFORMATION THE PROBLEM HAS NOT BEEN IDENTIFIED PLEASE CONTACT GENTEC CUSTOMER SUPPORT ON 61 2 9211 4422 or info gentecaustralia com au...

Страница 12: ...TM reece com au wolfen...