8
WOLFEN INSTALLATION MANUAL | Wolfen Pre Rinse Sink Mixer
INSTALLATION INSTRUCTIONS
1. Place the base o-ring (9) on the underside of
the mixer body (8).
2. Screw in the hot and cold flexible connectors
(57 & 58) to the mixer body (8).
3. Screw in the fixing bolt (55) into the mixer body
(8) and tighten with a screw driver.
4. Place the mixer unit over the pre-punched
tap hole in the sink. Feed the flexible
connectors through first.
5. From underneath the sink or basin, slide on
the U-shaped fixing washer (53), then the
U-shaped fixing plate (54).
6. Screw on the long hex nut (56) until the mixer
base is firmly fixed to the sink. Tighten with a
socket set or tube spanner.
7. Connect the hot and cold flexible connectors
to the inlet isolation valves.
The unit must be
installed with the main mixer handle to the
side.
8. Fit the main riser assembly into the mixer body
by pushing the twin o-ring spigot downward,
then fit and tighten the allen key screw (10) with
the allen key provided (11).
Note: the wall support bar (44) can be slid up or
down to the desired height to enable fixing to the
wall or splashback.
9. Ensuring the riser is 90 degrees to the wall,
measure and cut the wall support bar to a
length with a 2 to 5mm gap from the wall.
10. Slide on the chrome cover flange (45), nut (46),
brass olive (48) & wall fixing plate (49) onto the
wall support bar (44) as shown in exploded
parts diagram.
11. Fit the o-ring (47) to the groove on the fixing
wall plate.
12. Swing the wall support bar into position and
mark the three holes for drilling into the wall.
13. Swing the wall support bar to the left or right to
enable the three holes to be drilled.
14. For a masonry wall use the wall anchors
provided (51) with screws (50).
15. For a timber backed wall use the screws
provided (50).
Note: For a stainless steel splashback and/or cool
room panel wall, ensure the fixing method used
results in a solid fixing.
16. Swing the wall support bracket back into
position, line up the holes and screw the fixing
plate back to the wall. Tighten the brass nut and
olive, ensuring a firm and solid installation. Slide
the chrome cover plate over the wall plate.
Note: The brass MI thread on the end of the end of
the trigger spray hose swivels, so you do not have
to spin the whole hose around when connecting the
hose to the riser assembly.
17. Fit the flat washer (31) into the top of the riser
assembly to ensure a water tight seal.
Important Note
Mixer must be installed to the requirements of AS/NZS 3500 by
a qualified plumber. Your mixer comes to you already factory
assembled and tested. We do not recommend the dismantling
of any internal part of the mixer. The mixers are factory tested
and sealed so as to give the best performance.
Installation Instructions
1. Please flush out new pipe work prior to connecting the
new mixer.
2. All mixers should be installed with isolating stop cocks
(Arco brand recommended).
3. This tap is suitable for high pressure applications where both
hot and cold water supply pressures are at 150kPa or above.
WOLFEN INSTALLATION MANUAL | Installation Instructions
* To ensure longevity of the product we recommend Pressure reduction valves (PRV's)
not pressure limiting valves (PLV's) set at 350kPa working pressure (hot/cold).
Содержание Pre Rinse Sink Mixer
Страница 12: ...TM reece com au wolfen...