background image

Install the Warming Drawer

Unpack the warming drawer on a flat surface. Remove all

packaging materials from inside the warming drawer. Do

not discard the package containing the two wood screws

needed for installation.

Turn power off to the electrical outlet.

Slide the left corner of the warming drawer into the

opening. If the electrical outlet is installed inside the

opening, plug the power cord into the outlet. The excess

cord should be coiled behind or beside the unit. If the

outlet is located in an adjacent cabinet, thread the power

cord through the hole in the cabinet wall. Push the drawer

back into the opening until the trim meets the cabinet

front. Make sure the power cord does not get trapped

under the warming drawer.

IMPORTANT NOTE:

Do not lift up on the handle to push

the drawer into place.

Open the warming drawer to its full extension. Drill pilot

holes in each side hole, located toward the front on each

side of the warming drawer. Install the wood screws

provided with the unit. Refer to the illustration below.

Turn power back on to the electrical outlet.

LOCATION OF

SIDE HOLE

Location of side hole.

Anti-Tip Block

INSTALL ANTI-TIP BLOCKING

Install an anti-tip block against the rear cabinet wall. When

the warming drawer is installed below a built-in oven, you

may use a

7

/

8

"

(22)

thick platform to allow the warming

drawer trim and the oven trim to meet. The platform will

act as an anti-tip device for the warming drawer.

An anti-tip block or platform must be installed to

prevent the warming drawer from tipping forward while

opened when loaded. Failure to do so could result in

personal injury and damage to the cabinet.

Warming Drawer Installation

14

Содержание WWD30O

Страница 1: ...Warming Drawers INSTALLATION GUIDE ...

Страница 2: ...ions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Warming Drawers 3 Installation Considerations 4 Warming Drawer Specifications 8 Warming Drawer Installation 14 Service Information 15 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date info...

Страница 3: ...ce with National Electrical Codes as well as all state municipal and local codes The correct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product rating plate Record the model and serial numbers before i...

Страница 4: ...all four sides Check with local utilities for electrical codes that apply in your area Local codes vary Installation electrical connections and grounding must comply with applica ble codes In the absence of local codes the drawer should be installed in accordance with National Electri cal Code ANSI NFPA 70 1990 or latest edition Model WWD30O is CSA approved for outdoor installations TOOLS AND MATE...

Страница 5: ...rawer may be installed below a Wolf cooktop or sealed burner rangetop Allow enough room for gas and electrical connections for the cooktop The warming drawer may be installed next to or above another Wolf warming drawer Model WWD30O may be installed below a Wolf outdoor grill Electrical Requirements Power Supply 120 V AC 50 60 Hz Circuit Breaker 15 or 20 amp Receptacle 3 prong grounding type Elect...

Страница 6: ...the trim and handle of your oven The E series 2 51 thick drawer front with pro handle in 30 762 and 36 914 widths is designed to be installed below a sealed burner rangetop or outdoor gas grill so the panel aligns properly with the front of the rangetop or grill Keep in mind overall dimensions for the warming drawer remain the same even though the drawer front may be wider to match a Wolf 36 914 w...

Страница 7: ...ons STANDARD RECESSED OR FLUSH INSET INSTALLATION The warming drawer with E series drawer front can be installed in a standard recessed or flush inset application For a standard installation the drawer collar and front panel sit proud of the cabinet face frame A recessed installation requires the cabinetry be recessed by 3 16 5 so the collar is flush with the cabinet face frame but the drawer fron...

Страница 8: ... Location of electrical supply within opening may require additional cabinet depth Dashed line represents profile of unit FRONT VIEW SIDE VIEW E 24 610 min CABINET DEPTH 285 8 727 OPENING WIDTH PLATFORM 91 8 232 OPENING HEIGHT 103 8 264 231 2 597 TYPICAL 36 914 FLOOR TO COUNTERTOP Standard Installation L SERIES E SERIES OR INTEGRATED DRAWER FRONT ...

Страница 9: ...on of electrical supply within opening may require additional cabinet depth Dashed line represents profile of unit FRONT VIEW SIDE VIEW 303 8 772 FLUSH INSET WIDTH 285 8 727 OPENING WIDTH 7 8 22 PLATFORM 7 8 22 TOP AND SIDE CLEATS 36 914 FLOOR TO COUNTERTOP 107 8 276 FLUSH INSET HEIGHT 91 8 232 OPENING HEIGHT E E SIDE CLEATS 24 610 min FLUSH INSET DEPTH 1 25 TOP VIEW ANTI TIP BLOCK Flush Inset Ins...

Страница 10: ...thin oven opening may require additional cabinet depth FRONT VIEW SIDE VIEW 285 8 727 WARMING DRAWER OPENING WIDTH 281 2 724 OVEN OPENING WIDTH E E MICROWAVE OPENING 273 16 691 11 2 38 min E SERIES 1 25 min L SERIES 91 8 232 3 4 19 min PLATFORM E E 5 127 4 102 Standard Tower Installation INSTALLATION WITH MICROWAVE AND BUILT IN OVEN ...

Страница 11: ...t FRONT VIEW SIDE VIEW TOP VIEW 105 8 270 FLUSH INSET HEIGHT 91 8 232 OPENING HEIGHT E 1 25 PLATFORM 285 8 727 WARMING DRAWER OPENING WIDTH 17 432 OPENING HEIGHT 181 2 470 FLUSH INSET HEIGHT 271 2 699 STANDARD MICROWAVE OPENING WIDTH E 281 2 724 E SERIES OVEN OPENING WIDTH 11 16 17 TOP CLEAT 9 16 14 PLATFORM 1 25 SIDE CLEATS E E 5 127 4 102 273 16 691 OPENING HEIGHT 281 8 714 min FLUSH INSET HEIGH...

Страница 12: ...IDE VIEW TOP VIEW 105 8 270 FLUSH INSET HEIGHT 91 8 232 OPENING HEIGHT E 1 25 PLATFORM 285 8 727 WARMING DRAWER OPENING WIDTH 187 8 479 OPENING HEIGHT 201 8 511 FLUSH INSET HEIGHT 271 2 699 CONVECTION MICROWAVE OPENING WIDTH E 281 2 724 E SERIES OVEN OPENING WIDTH 1 2 13 TOP CLEAT 9 16 14 PLATFORM 1 25 SIDE CLEATS E E 5 127 4 102 273 16 691 OPENING HEIGHT 281 8 714 min FLUSH INSET HEIGHT 15 8 41 P...

Страница 13: ...4 32 FOR MICROWAVE 1 25 FOR OVEN AND WARMING DRAWER Platform must support 250 lbs 113 kg NOTE Location of electrical supply within oven opening may require additional cabinet depth Dashed line represents profile of unit FRONT VIEW SIDE VIEW TOP VIEW 143 4 375 OPENING HEIGHT 153 8 391 FLUSH INSET HEIGHT 1 25 SIDE CLEATS 105 8 270 FLUSH INSET HEIGHT 91 8 232 OPENING HEIGHT E 1 25 PLATFORM 285 8 727 ...

Страница 14: ...ORTANT NOTE Do not lift up on the handle to push the drawer into place Open the warming drawer to its full extension Drill pilot holes in each side hole located toward the front on each side of the warming drawer Install the wood screws provided with the unit Refer to the illustration below Turn power back on to the electrical outlet LOCATION OF SIDE HOLE Location of side hole Anti Tip Block INSTA...

Страница 15: ... at 800 222 7820 When calling for service you will need the model and serial numbers of the warming drawer Both numbers are listed on the product rating plate located on the left front floor area of the inner cabinet To access the rating plate the drawer must be fully open Refer to the illustration below wolfappliance com specs The information and images in this guide are the copyright property of...

Страница 16: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 222 7820 816978 REV A 1 2011 ...

Отзывы: