DESCRIPTION OVERVIEW:

Element

:

The element will be powered by the element relay (normally-open contacts).  This allows the element to be disabled
under most conditions.  Only during a call for heat from the main controller, will the element relay be energized.  

Fan:

The fan will be powered by the fan relay (normally-open contacts).  This allows the fan to be disabled under most
conditions.  Only during a warming mode from the main controller, will the fan be in use.

Drawer Input:

The drawer switch will be a normally open switch, (when drawer is open), and closed when drawer is closed.
When drawer is opened and is in a normal heating mode, unit will de-energize relays to fan and element. If back
lighting of the LCD is enabled, then opening of the drawer will turn on back lighting, and by closing the drawer, back
lighting will go off.

NOTE

:

Sabbath mode has unique requirements.  Please see Sabbath mode this section.

User Display:

The user display shows warming drawer preset temperature, any timed feature which is in process, and whether the
unit is in Proof mode. Other indicators include the ‘ON’ indicator which notes when unit is heating, (always on when
in the Sabbath mode),  and displays which temperature units, (°F or °C), the temperature is being displayed in.  
This area also informs user if there is an issue with the control and will display an error code in the temperature
and/or timer display. The user display numbers will be displayed as shown in the following pages.

The characters in the user display will only be illuminated when a normal warming mode, service diagnostic mode, or
kitchen timer is being used.  At all other times, display will be remain off.

The “PROOF” is on anytime “PROOF” mode is being used.

The “ON” indicator is on anytime control is calling for heat.  The exception is during Sabbath mode where the ”ON”
indicator stays on constantly.

NOTE

:

“TIMER” is on anytime there is a timed warming event or if kitchen timer is being used.

NOTE

“TIMER” is not an option in Sabbath mode.

POWER Key:

The “POWER” key is used to turn unit on and off.  While unit is in “OFF” mode, the Power key and “TIMER” up and
down arrow keys remain active.  If unit is powered up and Power key is pressed, the display will turn off along with
any associated backlighting.  If unit is off and the Power key is pressed, the control backlighting (if applicable), will
turn on and the rest of the keys will be active.

NOTE

If no other key is pressed within 20 seconds, unit will turn off.

TEMP Up/Down Key:

The “TEMP” up or down arrow keys can be used to adjust temperature.  By pressing and holding the up or down
arrow, unit will begin changing at the rate of 1º per ½ second until the first 5º increment is obtained.  If the user con-
tinues pressing, control will increment in 5º increments per ½ second.  The “TEMP” up or down arrow keys remain
active as long as control is On.

NOTE

Exception to this is in the Sabbath Mode.

NOTE

Temperature range is 80ºF to 200ºF, except in “PROOF” mode where maximum temperature is 120ºF.

TIMER Key:

The “TIMER” up or down arrow key is used to change time left in normal warming mode.  Timer keys can also be
used as a Kitchen Timer. The rate of this ascension shall be ½ second per increment and in the following order:  one
minute from 1-5 minutes; every five minutes from 5-30 minutes; 30 minute increments up to 5 hours; then hourly up
to 24 hours. At any time during a Normal Heating Mode, operator can adjust time left for warming by pressing
“TIMER” up or down arrow keys.

NOTE

:

The exception to this is during the Sabbath Mode (only the “Power On/Off” key is active in this mode).

Содержание WWD30-2

Страница 1: ...ontrol will open the element relay Once the control sees a thermistor temperature of 5ºF below set point the relay will close allowing element to cycle on Power Relay Board Circulation Fan Element Display Board Keypad Flex Cable Inner ceiling Network Cable Electronic Control Board Behind Front Panel Door Switch Bottom of Drawer Front Display Beeper CONTROL all low temp components Keypad Communicat...

Страница 2: ... will be remain off The PROOF is on anytime PROOF mode is being used The ON indicator is on anytime control is calling for heat The exception is during Sabbath mode where the ON indicator stays on constantly NOTE TIMER is on anytime there is a timed warming event or if kitchen timer is being used NOTE TIMER is not an option in Sabbath mode POWER Key The POWER key is used to turn unit on and off Wh...

Страница 3: ...nit will switch off NORMAL WARMING MODE Normal warming mode is the basic operating mode when power is turned on and any warming function is selected This will include heating by the element and circulation of air by use of the fan Mode Entry The unit can be placed into a normal warming mode by simply pressing the Power On Off key followed by either TEMP up or down arrow keys or any preset is press...

Страница 4: ...lash when first entering mode Once mode is active the TIMER will no longer be illuminated If no time is set timer will automatically default to 4 00 hours This ensures a definitive stop time Operations When HIGH Preset key is depressed control will display 200F in temperature display For MED temperature display will read 160F and for LOW temperature display will read 120F In timer area of display ...

Страница 5: ...nt and fan maintains drawer temperature to set point temperature Fan is on while element is on during warming mode as long as drawer switch returns a drawer closed value If element has cycled off fan will continue to circulate air inside drawer for a pre determined time before turning off Fan will then re energize when element is turned back on during a call for heat PREHEAT Preheat can be describ...

Страница 6: ...first 5 second increment is obtained then will increase by 5 seconds per 1 2 second If TIMER up or down arrow key is depressed for longer than 30 seconds display will increase by 30 minute increments each 1 2 second until 5 00 Hours is reached then increase in one hour increments up to 24 00 hours NOTE Timer will count up in time with 1 minute as the minimum setting and going up to 24 00 hours min...

Страница 7: ... drawer is open for longer than 1 minute and the unit calls for heat element will randomly turn on and off If in Sabbath mode but a second key press does not occur withing 10 seconds the unit will enter OFF mode Mode Exit A press of the Power On Off key will terminate Sabbath mode and shut off unit at any time TIMER PROOF LOW PRESETS HIGH MED TEMP POWER ON OFF PROOF F TEMP TEMP TEMP ON TIMER Figur...

Страница 8: ...es must be made when unit is in OFF mode See Figure 3 20 for a quick reference to keystrokes to enter modes and features Temperature Display Preference Control can be switched between Fahrenheit or Celsius by pressing and holding both TEMP up and down arrow key for 5 seconds Use the TEMP Up or Down arrow key to change from F to C or C to F See Figure 3 12 NOTE Press Power On Off key to exit and sa...

Страница 9: ...sed on drawer state at full illumination NOTE Left side of display will show On continuously and the right side of display will flash between bclt and Sab Continuous mode Off refers to backlight continuously off only in Sabbath mode Outside of Sabbath mode back light works as normal based on drawer state at full illumination NOTE Left side of display will show Off continuously and the right side o...

Страница 10: ...l control information parameters such as total hours used See Figure 3 17 3 19 NOTES Using the opposite TIMER up or down arrow key will reverse your previous order To clear error codes logged press and hold TIMER up and down arrow keys for 5 seconds while in Field Service Mode See Troubleshooting Section 5 for list of error codes and meanings NOTE Once you have made it through all errors and infor...

Страница 11: ...perature over 10 minutes of continuous call for heat Occurs only during preheat mode and the door is closed Door switch closed when the keypad is being operated or unit turned on Drawer temperature rises to 250ºF in any mode state Cable wires that activate element or fan relays on power board are not making connection Replace Control Board In FSM Field Service Mode view temper ature as view by the...

Страница 12: ... Display Contrast Change Mode LED Back Lighting Change Mode TEMP ELE Func ON Relay closed Element on TEMP ELE Func OFF Relay Opens Element Off TEMP Fan Func ON Relay closed Fan turns on TEMP Fan Func OFF Relay Opens Fan turns Off TEMP Dor CLOS if Drawer Closed OPEn If Drawer Open key press TEMP DISPLAY TIMER DISPLAY ON INDICATOR POWER ON OFF PROOF MED POWER ON OFF 5 Seconds 5 Seconds POWER ON OFF ...

Отзывы: