98
|
Wolf Customer Care 800.222.7820
WOLF SEALED BURNER RANGETOPS
RANGES / RANGETOPS
VENTILA
TION
COOKTOPS / COFFEE SYSTEMS
OVENS / W
ARMING DRA
WERS
OUTDOOR GRILLS
Planning Information
The platform to support the sealed burner rangetop must
include a cut-out for electrical and gas supply connections.
Refer to the chart below for minimum base support.
When installing against a combustible surface, a minimum
5"
(127)
riser is required for model SRT366, and a minimum
10"
(254)
riser is required for 36" and 48" sealed burner
rangetops with a charbroiler or griddle. Follow all minimum
clearances to combustible surfaces shown in the illustration
on the following page.
A Wolf pro ventilation hood is recommended with the sealed
burner rangetop. If the rangetop is to be installed without
ventilation, a 36"
(914)
minimum clearance, 44"
(1118)
for
charbroiler, from countertop to combustible materials
above the rangetop is required. Refer to page 120 for pro
ventilation.
A downdraft can be used with models SRT304 and SRT366.
An accessory trim kit is necessary for this installation. Con-
tact an authorized Wolf dealer for details.
INSTALLATION REQUIREMENTS
PLATFORM
Thickness
3
/
4
"
(19)
BASE SUPPORT
MIN
30" Rangetop
200 lb
(91 kg)
36" Rangetop
250 lb
(113 kg)
48" Rangetop
300 lb
(136 kg)
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration on the following page. A separate circuit,
servicing only this appliance is required.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 110/120 VAC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
6'
(1.8 m)
GAS SUPPLY
A gas supply line of
3
/
4
"
(19)
rigid pipe must be provided to
the rangetop. If local codes permit, a certified, 3'
(.9 m)
long,
1
/
2
"
(13)
or
3
/
4
"
(19)
ID flexible metal appliance connector is
recommended to connect the units
1
/
2
" NPT female inlet to
the gas supply line.
Wolf natural gas rangetops will function up to 10,250'
(3124 m)
in altitude without adjustment and LP gas ran-
getops up to 8,600'
(2621 m)
. If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS
WC
Supply Pressure
5"
(12.5 mb)
Min Line Pressure
7"
(17.5 mb)
Max Regulator Pressure
14"
(34.9 mb)
, .5 psi
(3.5 kPa)
LP GAS
WC
Supply Pressure
10"
(25 mb)
Min Line Pressure
11"
(27.4 mb)
Max Regulator Pressure
14"
(34.9 mb)
, .5 psi
(3.5 kPa)
Содержание SRT484CG
Страница 1: ...Wolf Design Guide ...
Страница 14: ...14 Wolf Customer Care 800 222 7820 ...
Страница 28: ...28 Wolf Customer Care 800 222 7820 ...
Страница 34: ......
Страница 46: ......
Страница 52: ......
Страница 74: ......
Страница 84: ......
Страница 90: ......
Страница 100: ......
Страница 108: ......
Страница 114: ......
Страница 120: ......
Страница 134: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 222 7820 WDG 11 2014 ...