background image

Planning Information

36"

(914) 

Gas Rangetops

M O D E L S   R T 3 6 6 ,   R T 3 6 4 C ,   R T 3 6 4 G   A N D   R T 3 6 2 F

Dimensions in parentheses are in
millimeters unless otherwise specified.

5

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, finished rough opening
dimensions and installation specifics.

IMPORTANT NOTE: 

Caution must be used in

planning the proper installation of the Wolf gas
rangetop to avoid any fires or damage to
adjacent cabinetry or kitchen equipment. Be
sure to follow minimum clearances established
in the finished rough opening dimensions as
shown in the illustration on page 4.

IMPORTANT NOTE:

In non-island applications,

a riser is required when installing a gas rangetop
against a combustible surface.

The platform for the rangetop must be 

3

/

4

"

(19) thick and include a cut-out at the right rear
for gas supply and electrical connections. The
platform must be level to ensure that the
cooking surface is level.

A Wolf Pro ventilation hood or hood liner is

recommended. When installing a ventilation
hood, refer to the specific requirements of the
hood for the minimum dimension to countertop.
Also refer to the ventilation recommendation
charts in the Pro ventilation section of our
website, wolfappliance.com.

The Wolf gas rangetop requires a 110/120 V

AC, 50/60 Hz electrical supply to operate the
electronic ignition system. The 6' (1.8 m) power
supply cord provided with the rangetop is
equipped with a 3-prong, grounded plug for
protection against shock hazard. The service
should have its own 15 amp circuit breaker.
Locate electrical within the shaded area shown
in the illustration on page 4.

IMPORTANT NOTE:

A ground fault circuit

interrupter (GFCI) is not recommended and may
cause interruption of operation.

Wolf gas rangetops are designed to operate

on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP gas at 10" (25 mb) WC
pressure. The minimum line pressure for natural
gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC
for LP gas. The maximum gas supply pressure
to the regulator should never exceed 14" (34.9
mb) WC; .5 psi (3.5 kPa).

Wolf recommends the use of a 

1

/

2

" (13) I.D.

commercial type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be 

3

/

4

" (19) minimum I.D. pipe. 

IMPORTANT NOTE: 

A separate external gas

shut-off valve must be located near the range in
an accessible location. 

You must follow all National Electrical Code

and gas regulations. In addition, be aware of
local codes and ordinances when installing
your services.

Wolf gas rangetops using natural gas

function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas and LP gas
installations from 8,000' (2438 m) to 11,000'
(3353 m) need the high altitude kit. Contact
your Wolf dealer for details. To obtain local
dealer information, visit the Showroom Locator
section of our website, wolfappliance.com.

Refer to the installation instructions

shipped with each Wolf product for detailed
specifications.

Содержание RT362F

Страница 1: ...tchen In fact the Wolf framed ovens would be a beautiful complement to these cooking instruments Wolf gas rangetops offer a variety of top configurations and standard dual brass surface burners Optional infrared griddle infrared charbroiler and French Top give you the freedom to customize your gas rangetop Let Wolf the corporate companion and kitchen soul mate of Sub Zero fuel your passion for coo...

Страница 2: ...nch Top configurations Classic stainless steel exterior finish Dual brass burners with automatic reignition at all settings 500 Btu hr 1 kW simmer to 16 000 Btu hr 4 7 kW high Porcelain coated cast iron top grates Large red control knobs with four position settings and chrome bezels optional black knobs available Stainless steel drip tray on ball bearing slides High altitude conversion kit availab...

Страница 3: ...rdwood cutting board griddle model only High altitude conversion kit Accessories are available through your Wolf dealer To obtain local dealer information visit the Showroom Locator section of our website wolfappliance com S P E C I F I C A T I O N S Overall Rangetop Width 36 914 Overall Rangetop Height to cooking surface 101 2 267 Overall Rangetop Depth 271 4 692 Surface Burners 16 000 Btu hr 4 7...

Страница 4: ... 330 36 914 18 min 457 TO COUNTERTOP LOCATION OF GAS AND ELECTRICAL SUPPLY CUT OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM 30 min 762 TO 36 max 914 COUNTERTOP TO BOTTOM OF VENTILATION HOOD 6 min 152 TO COMBUSTIBLE MATERIALS BOTH SIDES 30 min 762 COUNTERTOP TO COMBUSTIBLE MATERIALS 36 min 914 FOR CHARBROILER VENTILATION HOOD I N S T A L L A T I O N S P E C I F I C A T I O N S D I M E N S I O ...

Страница 5: ...on system The 6 1 8 m power supply cord provided with the rangetop is equipped with a 3 prong grounded plug for protection against shock hazard The service should have its own 15 amp circuit breaker Locate electrical within the shaded area shown in the illustration on page 4 IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation Wolf gas r...

Отзывы: