IMPORTANT INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY, OBSERVE THE FOLLOWING:

Installation work and electrical wiring must be
done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated
construction.

Two installers are recommended due to the size and
weight of the pro ventilation hood.

Install the pro ventilation hood only with a blower
manufactured by Wolf.

When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

Safety Instructions

4

To reduce the risk of fire and properly exhaust air,
be certain to duct air outside. Do not vent exhaust
air into spaces within walls or ceilings or into attics,
crawl spaces or garages.

TO REDUCE THE RISK OF INJURY TO PERSONS IN
THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:

Smother flames with close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. Be careful to
prevent burns. If the flames do not go out immedi-
ately, evacuate and call the fire department.

Never pick up a flaming pan—you may be burned.

Do not use water, including wet dishcloths or towels
—a violent steam explosion will result.

USE AN EXTINGUISHER ONLY IF:

You know you have a class ABC extinguisher and
you already know how to operate it.

The fire is small and contained in the area where it
started.

The fire department is being called.

You can fight the fire with your back to an exit
(NFPA fire safety tips).

TO REDUCE RISK OF RANGE TOP GREASE FIRE:

A) Never leave surface units unattended at high

settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on
low or medium settings.

B) Always turn the ventilation hood on when

cooking at high heat or when flambeing foods
such as crepes suzette or cherries jubilee.

C) Clean ventilation fans frequently. Grease should

not be allowed to accumulate on fan or filter.

D) Use proper pan size. Always use cookware

appropriate for the size of the surface burner.

The hood motor has a thermal overload which will
automatically shut off the motor if it becomes over-
heated. The motor will restart when it has cooled
down. If the motor continues to shut off and restart,
have the hood serviced.

Содержание Pro Wall Chimney Ventilation Hoods

Страница 1: ...Pro Wall Chimney Ventilation Hoods INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...NG states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Pro Wall Chimney Ventilation Hoods 3 Safety Instructions 4 Installation Considerations 5 Pro Wall Chimney Hood Specifications 6 Pro Wall Chimney Hood Installation 8 Service Information 18 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs f...

Страница 3: ...onal Electrical Codes as well as all state municipal and local codes The correct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product rating plate Record the model and serial numbers before installing th...

Страница 4: ...not go out immedi ately evacuate and call the fire department Never pick up a flaming pan you may be burned Do not use water including wet dishcloths or towels a violent steam explosion will result USE AN EXTINGUISHER ONLY IF You know you have a class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being ca...

Страница 5: ...e When performing installation servicing or cleaning the ventilation hood it is recommended that safety glasses and gloves be worn BLOWER ASSEMBLIES Wolf pro ventilation hoods are shipped without the blower assembly Internal in line and remote blowers are avail able through your authorized Wolf dealer For local dealer information visit the find a showroom section of our website wolfappliance com T...

Страница 6: ...4 610 OVERALL DEPTH 131 2 343 WIDTH MINUS 18 457 36 914 42 1067 48 1219 AND 54 1372 WIDTHS PRO WALL CHIMNEY HOODS Installation Specifications PRO WALL CHIMNEY HOODS E 6 152 5 127 LOCATION OF ELECTRICAL WIDTH OF HOOD 30 762 TO 36 914 TO COUNTERTOP 18 457 HEIGHT OF HOOD 24 610 DEPTH OF HOOD ...

Страница 7: ... wall chimney hoods Electrical Requirements Wolf pro ventilation hoods require a separate grounded 120 V AC 60 Hz power supply The service should have its own 15 amp circuit breaker Locate the electrical supply through the top of the hood within the shaded area shown in the installation specifications illustration on the previous page IMPORTANT NOTE You must follow all National Electrical Code reg...

Страница 8: ... a remote blower is used with a short duct run Unless you are using a remote blower a roof or wall cap must be installed Connect 10 254 round metal ductwork to the cap and work back towards the hood Use duct sealing tape to seal joints between ductwork sections Pro wall chimney hoods have a backdraft damper included in the transition assembly Local codes may require the use of an additional backdr...

Страница 9: ...ct the wall framing using minimum 2 x 4 lumber Proper structural support is required to accom modate the weight of the hood 3 Mark the center location of the hood Install 2 x 4 blocking between wall studs Refer to the illustration below 4 Position the wood mounting strip provided with hood on the wall as shown in the illustration below Secure the mounting strip to wall studs and blocking using 10 ...

Страница 10: ... the hood for the Romex wire Refer to the in line and remote blowers section on page 16 and follow installation instructions provided with the blower Hood Preparation 1 Remove the filters of the pro wall chimney hood by pushing each filter up at the angle it is placed in then rotate the bottom of the filter down Refer to the illustration below Remove the center filter first Gloves should be worn w...

Страница 11: ...chimney hoods using a 600 CFM or 900 CFM internal blower refer to installation instructions provided with the blower assembly Install the internal blower prior to installing the duct cover 1 Attach the duct cover from the inside of the hood through the filter opening using the screws provided with the duct cover Leave screws partially loose until all screws are installed 2 Check alignment of the d...

Страница 12: ...ith the blower 6 Proceed with hood wiring connections Pro Wall Chimney Hood Installation 12 Hood Installation IMPORTANT NOTE If an optional duct cover is to be used with the pro wall chimney hood it must be installed before installing the hood Refer to duct cover installation on the previous page IMPORTANT NOTE If a backsplash is to be used it should be installed prior to mounting the wall chimney...

Страница 13: ... no wires are pinched between the cover and electrical box Blower Assemblies Pro ventilation hoods are shipped without the blower assembly Internal in line and remote blowers are avail able through your authorized Wolf dealer For local dealer information visit the find a showroom section of our website wolfappliance com The blower will vary in size and is dictated by the cooking surface the volume...

Страница 14: ... and wiring instructions BLOWER INSTALLATION 600 CFM AND 900 CFM 1 Fasten four hex nuts provided with blower to the four threaded blower studs leaving a 1 4 6 gap Refer to the illustrations below 2 Lift the blower into position inside the hood 3 Engage all the blower studs in the keyholes on top of the hood From the top of the hood secure the blower to the hood with the four hex nuts on the blower...

Страница 15: ...running it through the other wire clamp previously installed Tighten the wire clamp to secure the cable 3 Cut off the butt crimp connector from the end of orange wire in hood Strip orange wire about 3 8 10 Using an appropriate wire connector not included connect black wire from blower to orange wire in hood 4 Using the wire connectors provided connect black wire to power supply black wire all whit...

Страница 16: ...tional mounting and wiring instructions Locate the blower so that the length of the duct run and number of elbows and transitions are kept to a minimum The duct run should be no longer than 50 15 m Remote blowers should be located between wall studs or roof rafters Avoid pipes wires and other ductwork Allow enough space for transitions needed between the blower and connecting ductwork For best per...

Страница 17: ...the illustration below While pressing up against the spring rotate the bottom edge of the filter into position next to the grease cup Gloves should be worn when handling filters LOGO NAMEPLATE The Wolf logo nameplate does not come installed on the wall chimney hood since there are various locations that the nameplate can be attached Once you ve decided on the location for the nameplate clean the m...

Страница 18: ...formation If service is necessary maintain the quality built into your ventilation hood by calling a Wolf authorized service center To obtain the name and number of a Wolf authorized service center check the contact support section of our website wolfappliance com or call Wolf customer service at 800 332 9513 When calling for service you will need the model and serial numbers of the ventilation ho...

Страница 19: ...ance Inc all rights reserved Wolf Wolf Design Wolf Gourmet W Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance Inc Sub Zero Sub Zero Design Dual Refrigeration Constant Care and The Living Kitchen are registered trademarks and service marks of Sub Zero Inc collectively the Company Marks All other trademarks or registered trademarks are proper...

Страница 20: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 332 9513 817002 REV A 8 2010 ...

Отзывы: