background image

 
 
 

 

IMPORTANT! 

 

CAUTION

:  Please read this entire manual before you install and use your new room heater. For your safety, follow these 

installation, operation and maintenance instructions exactly, without deviation. Failure to follow these instructions may 
result in property damage, bodily injury, or even death. If this appliance is not properly installed, a house fire may result. 
Contact your local building or fire officials about restrictions and installation inspection requirements in your area. 
 
1.

 

If using an older chimney, it must be inspected for adequate serviceability. Refer to 

Chimney Inspection

 on page 11 

of this manual. 

2.

 

The minimum clearances must be maintained for all combustible surfaces and materials, including furniture, carpet, 
drapes, clothing, wood, papers, etc. Do not store firewood within this clearance space. Failure to maintain clearances 
to all combustible materials may result in a house fire. 

3.

 

This appliance requires non-combustible floor protection as outlined in this manual (see 

Floor Protection

 on page 8 

for additional information). 

4.

 

Minimum ceiling height must be 7 feet (213 cm) (measured from base of appliance to ceiling). 

5.

 

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE THAT IS CONNECTED TO ANOTHER 
APPLIANCE. 

6.

 

Do not connect this appliance to air ducts or any air distribution system. 

7.

 

PREVENT CREOSOTE FIRE: Inspect and clean  chimney frequently. Under certain conditions of use, creosote 
build-up can occur rapidly. Inspect chimney connector and chimney twice monthly and clean if necessary. Using 
green or inadequately seasoned wood can greatly increase creosote build-up. Use dry  wood only to minimize creo-
sote build-up. 

8.

 

USE SOLID WOOD FUEL ONLY: This appliance is approved for burning dry, seasoned, natural wood only. 
CAUTION: BURN UNTREATED WOOD ONLY. DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS 
SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL. 

9.

 

Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen 
up” a fire in this heater. Keep all such liquids well away from heater while it is in use. 

10.

 

DO NOT OVERFIRE: If heater or chimney connector glows, you are overfiring. Overfiring this appliance could 
cause a house fire. Overfiring is a condition where the appliance is operated at temperatures above its design capa-
bilities. Overfiring can be caused by improper installation, improper operation, lack of maintenance or improper fuel 
usage. Damage caused from overfiring is NOT covered under the manufacturer’s limited warranty. 

11.

 

NEVER LEAVE AN UNATTENDED STOVE BURNING ON HIGH. Operation of the stove with the primary air 
control at its highest burn rate setting for extended periods can cause dangerous overfiring conditions. The primary 
air control should only be positioned at the highest setting during start-up procedures and for short durations. When 
leaving the stove unattended, ensure that the primary air control is set to the low or medium low range. 

12.

 

Use the metal ash drawer only to dispose of ashes. 

13.

 

IN THE EVENT OF A COMPONENT FAILURE, USE ONLY COMPONENTS PROVIDED BY THE 
MANUFACTURER AS REPLACEMENT PARTS. 

14.

 

Burning any kind of fuel uses oxygen from the dwelling. Be sure that you allow an adequate source of fresh air into 
the room where the stove is operating (see 

Ventilation

 and 

Outside Air

 on page 9). 

15.

 

CAUTION: HOT WHILE IN OPERATION. An appliance hot enough to warm your home can severely burn anyone 
touching it. Keep children, clothing and furniture away. Contact may cause skin burns. Do not let children touch the 
appliance. Train them to stay a safe distance from the unit. 

16.

 

Do not operate this appliance without the firebox baffle brick properly installed. 

17.

 

Build fires directly upon the brick hearth inside the stove. Do not use grates, irons or any other method to elevate the 
fire. 

18.

 

SAVE THESE INSTRUCTIONS. 

19.

 

See the listing label located on the back of stove (or see Safety/Listing Label on page 24). 

20.

 

It is highly recommended to install a smoke dectector in the home when installing a wood stove. 

Содержание Lascar

Страница 1: ...tenance Manual for Stromboli Lascar Manufactured by Imported by Frohnhof 9 PO Box 120 91580 Petersaurach Pound Ridge NY Germany T 49 9802 951473 T 914 764 5679 F 49 9802 9589909 F 614 764 0465 www wolf bavaria com www wittus com ...

Страница 2: ...Installation Operator Maintenance Manual STROMBOLI Model 0700 Steel Model 0701 Soap Stone Model 0702 Tiles LASCAR Model 0601 Soap Stone Model 0602 Tiles ...

Страница 3: ...l kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater Keep all such liquids well away from heater while it is in use 10 DO NOT OVERFIRE If heater or chimney connector glows you are overfiring Overfiring this appliance could cause a house fire Overfiring is a condition where the appliance is operated at temperatures above its design capa bilities Overfiri...

Страница 4: ...cern for aesthetics efficiency and our environment We extend our continued support to help you achieve the maximum benefit and enjoyment available from your new German wood stove It is our goal at Wolf Bavaria to provide you our valued customer with an appliance that will ensure you years of trouble free warmth and pleasure Thank you for selecting a Wolf Bavaria Products stove as the answer to you...

Страница 5: ...8 Combustible Wall Chimney Connector Pass Throughs 15 3 User s Guide 16 3 1 Hand Protection 16 3 2 Technical Data and Dimensions 16 3 3 Delivery 17 3 4 Unpacking 18 3 5 Acceptable Fuel 18 4 Safety Please read very important 18 5 Fresh Air Supply 19 6 Operating Your Woodstove 19 6 1 Regulating the Heat 19 6 2 Door 20 6 3 Ash Drawer 20 7 Heating Operation 20 7 1 First Use 20 7 2 Starting a Fire 21 7...

Страница 6: ...82 Canadian Test Standard CAN ULC S627 EPA Exemption Certification Packaging List One Installation and operation instruction manual One Warranty One Set of Baffle Bricks One Set of Tiles or Soap Stone One Glove One Lever for the Secendary Air Using this Manual Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provi...

Страница 7: ...herefore a central location is often best There are other practical considerations which must be considered before a final selection of location is made Existing Chimneys Wood Storage Aesthetic Considerations Roof Design Rafter Locations Roof Pitch Room Traffic Proximity to Combustibles Electrical Wiring The installation of this stove will require some research Once your options are determined con...

Страница 8: ...460 E 18 460 B 12 305 D 11 280 Clearances Canada inches millimeters A 21 535 C 27 685 E 27 685 B 21 535 D 20 510 The minimum clearance from the stove front is 52 inch 1320mm for both Canada and US This dinension must be used by a rotable 360 Stove PROTECTED WALL CLEARANCE when the stove is installed adjacent to a protected wall system the variance must be approved by your local building official N...

Страница 9: ...r protector must be installed with an R value of 1 0 English units Use of a listed floor protector is acceptable An easy means of determining if a proposed alternate floor protector meets these requirements is to follow this proce dure 1 Convert specification to R value i R value is given no conversion is needed ii k factor is given with a required thickness T in inches R 1 k x T iii C factor is g...

Страница 10: ... of the above symptoms 4 The house is equipped with a well sealed vapor barrier and tight fitting windows and or has any powered devices that exhaust house air 5 There is excessive condensation on windows in the winter 6 A ventilation system is installed in the house b If these or other indications suggest that infiltration air is inadequate additional combustion air should be provided from the ou...

Страница 11: ...fuel door Install the marble gasket and marble as follows 1 Install gasket on stove top as shown in the illustration The ceramic fiber blanket and strips cerawool which come with each unit must be placed under the marble to insulate it from high temperatures on top of the firebox Do not place the marble directly on the top metal surface of the stove or it will crack 2 Place top marble piece onto t...

Страница 12: ...iece usually called a dripless connector to join single wall pipe to their factory built chimney section Minimum Flue Size The required minimum diameter and area required for the flue size is respectively 6 152 mm diameter which is approximately 28 square inches 711 square mm The maximum flue size should be no more than three times the cross sectional area of the size of the 6 152 mm diameter flue...

Страница 13: ...ny additional re quirements for your area Due to prevailing winds local terrain adjacent tall trees a hill or ravine near the home or adjacent structures additional chimney height or a special chimney cap may be required to ensure optimum performance To achieve a stable draft the total flue height required from the appliance to termination is 12 to 15 feet 366 to 457 cm minimum 2 7 Draft Requireme...

Страница 14: ......

Страница 15: ...l thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 mm separation area containing fiber glass insula tion from the wall thimble and cover its opening with a 24 gage minimum sheet metal support Maintain the 6 152 mm space There should also be a support sized to fit and hold the metal chimney connector See that the support is fastened s...

Страница 16: ...3 User s Guide 3 1 Hand Protection Please use protective gloves when opening the doors You can then add wood while the handle is hot 3 2 Technical Data and Dimensions LASCAR STROMBOLI ...

Страница 17: ...alculated as follows according to DIN 18 893 for rooms that do not have insulation that complies with the Heat Insulation Ordinance For favorable heating conditions calculated according to DIN 4701 At less favorable heating conditions 145 m At unfavorable heating conditions 98 m For interval heating with interruptions of more than 8 hours the heating capacity is reduced by 25 3 3 Delivery Damage c...

Страница 18: ... first time This will provide you with information about how to safely operate your stove During operation the woodstove s surface will become very hot Pay attention in particular to children playing in the vicinity of the stove as they are most likely to be at risk of injury Keep small children away from the stove Make sure that no combustible material is located in the vicinity of or on top of t...

Страница 19: ...n The location that is used to support the base of the woodstove must be horizontal and without any uneven spots 6 Operating Your Woodstove 6 1 Regulating the Heat A control to regulate the secondary air is located above the door in the mid dle Open the faceplate under the fireplace door Reach into the recess and pull 1 Secondary Draft Control The secondary draft control lever regulates the amount...

Страница 20: ...oodstove should not be used until after you have obtained approval from the proper authorities regarding its proper installation and conditions of use The woodstove is designed to burn only wood i e pieces of wood or wood briquettes The wood must be dry moisture 20 and untreated The burning of any other materials such as chipboard painted laminated impregnated or synthetic coated wood garbage etc ...

Страница 21: ...ature As a result the wood does not burn up cleanly and soot is built up on the glass and the fireclay walls Therefore fill your woodstove about halfway with wood pieces and replenish on a regular basis Your woodstove is not a garbage burning incinerator Use only wood or wood briquettes for fuel 7 4 Adding Wood Do not add wood until the flames have stopped blazing First open the draft controls com...

Страница 22: ...lation and correct positioning of the chimney the glass will remain generally clean on its own Despite this fact a buildup of a fine layer of soot dust is often unavoidable and this is magnified by poor fuel wet wood and or constant draft with limited efficiency Important Only clean the glass after the woodstove has completely cooled Warning Do not use abrasive cleaners Only clean the glass after ...

Страница 23: ...le it is in operation The heating process causes the top surface of the woodstove as well as its operating elements including the window and flue to become extremely hot Do not touch any of these parts without appropriate protective gear or tools e g heat protection gloves Never put laundry or other objects on the stove to dry Objects that are not heat resistant should never be placed on top of th...

Страница 24: ... 1 Replacement Tiles 13 2 Replacement Glas and Door Handle IMPORTANT Replace glass only with glass from the manufacturer or distributor of this appliance Glass Dimensions Hight 550 0mm Width 420 0mm Thickness 4 0mm Radius 420 0mm ...

Страница 25: ...r of this appliance We sincerely hope that your Wolf Bavaria woodstove provides you with many cozy hours of warmth and enjoyment Manufactured by Imported by Frohnhof 9 PO Box 120 91580 Petersaurach Pound Ridge NY Germany USA T 49 9802 951473 T 914 764 5679 F 49 9802 9589909 F 614 764 0465 www wolf bavaria com www wittus com ...

Отзывы: