12

R E M O T E B L O W E R

IMPORTANT NOTE:

Before turning

the power on, make sure the blower
is in the "OFF" position. Use wire con-
nectors or wire nuts approved by UL
or C/UL. Refer to installation instruc-
tions provided with each blower to
verify wall or roof cut-outs.

STEP 1: Plan the Installation

1)

Locate the blower so the length of

the duct run and number of elbows
and transitions are kept to a mini-
mum.

2)

Where possible, blower should be

located between wall studs or roof
rafters.

3)

Avoid pipes, wires or other duct-

work that may be running through
the wall.

4)

Be sure that there is enough space

for any transitions that may be need-
ed between the blower and the con-
necting ductwork.

5)

For best performance, locate tran-

sitions nearest the blower.

Feed 6” of ROMEX through the
knockout opening hole and into the
wiring box on the rough-in plate of
liner. Secure the cable to wiring box
with an appropriate connector.

Locate cord assembly provided with
the remote blower. The cord assem-
bly has two leads, black (L1) and
white (neutral). Connect these leads
to the leads from the blower, black to
black and white to white.

Connect ALL green and bare wires
together to the ground screw in the
wiring box.

4)

Plug cord assembly into receptacle

located near the center of the liner
shell. Use clips on liner interior to
keep excess power cord away from
moving parts.

5)

Re-install wiring box cover and

screws. Make sure all wires are secure
and that no wires are pinched
between cover and box.

STEP 2: Connect Remote Blower

NOTE:

Always refer to all blower

installation instructions provided with
the blower for additional mounting
and wiring instructions.

1)

Remove cover from wiring box

inside of liner shell. Remove wiring
box knockout.

2)

Feed 6”  of inbound power cable

through the knockout opening hole
and into the wiring box. Secure the
cable to wiring box with an appropri-
ate connector for type of cable being
used. 

Connect leads as follows:

Black (L1) to black (loose) in the

J box from the switch.

Neutral to neutral (loose) in the

J box from the switch.

3) Wiring Remote Blower:

Follow

wiring instructions at the blower as
outlined in the particular blower
installation instructions. Black (L1) to
black, white (neutral) to white – or
white to blue, or white to brown
(depending on model) and green to
grounding screw. Run remote blower
cable (ROMEX) to the liner.

Remote Blower Dimensions-600CFM
(801640) and 900CFM (801641)

        24

1/2

"(622)

      15

1/2

"(394)

28

1/4

"(717)

20

3/4

"(527)

24

3/4

"(629)

14"(356)

        4

3/4

"(121)

10"(254)

DIAMETER

Remote Blower Dimensions-1200CFM
(801642)

Remote Blower Dimensions-1500CFM
(804701)

10"(254)

DIAMETER

          14

3/4

"(375)       

29

1/2

"(749)

29

1/2

"(749)

18"(457)

22"(559)

10

1/8

"(257)   

       7

1/4

"(184)

   10"(254)

10"(254)

DIAMETER

         14

3/4

"(375)  

29

1/2

"(749)

29

1/2

"(749)

21"(533)

25"(635)

10

3/8

"(264)

      7

1/4

"(181)

10"(254)

V

E N T I L A T O R

I

N S T A L L A T I O N

Содержание L282212I

Страница 1: ...P R O S E R I E S H O O D L I N E R S I N S T A L L A T I O N I N S T R U C T I O N S ...

Страница 2: ...lation must be completed by a qualified installer or service agency Before you begin installation read these instructions completely and carefully INSTALLER please retain these instructions for local inspector s reference then leave them with the homeowner Please read the entire installation instructions prior to installation HOMEOWNER please read and keep these instructions for future reference P...

Страница 3: ...ions Model L282212I 12 305 mm 221 2 572 mm 12 305 mm 283 8 721 mm 4 102 mm 223 8 568 mm F E A T U R E S Available for 30 36 42 48 54 and 60 ventilation hood shells I models include 600 cfm internal blower Recessed controls Halogen lighting with night light Stainless steel enclosed liner Stainless steel baffle filters Transition included Internal or remote blower option Heat Sentry feature Top disc...

Страница 4: ...ize the backflow of cold air into the room 4 Wolf recommends the hood liner be installed 30 to 36 above the cooking surface 5 Local building codes may require the use of make up air Consult your local HVAC professional for specific requirements in your area 4 Liner Installation Dimensions 30 TO 36 762 mm 914 mm COOKING SURFACE TO BOTTOM OF HOOD LINER 12 305 mm HEIGHT OF LINER HOOD LINER DUCTWORK I...

Страница 5: ...GHT OF LINER 221 2 572 DEPTH OF LINER WIDTH OF LINER DECORATIVE HOOD HOOD LINER HOOD LINER DECORATIVE HOOD COOKING SURFACE NOTE Dimensions in parentheses are in millimeters 6 152 5 127 LOCATION OF ELECTRICAL Cabinetry and Electrical Placement 5 Installation Cross Section Always use the interior measurements of the decorative hood and measure in multiple places The height of the liner does not have...

Страница 6: ...imensions needed for the proper installation of the ventilation hood liner A WIDTH OF LINER C L C L C TO CENTER OF TRANSITION D TO CENTER OF TRANSITION B HEIGHT OF TRANSITION P R O S E R I E S V E N T I L A T I O N H O O D L I N E R S I N S T A L L A T I O N C O N S I D E R A T I O N S Shipping Weights for Hood Liners Model Number Shipping Weight L282212I 57 lbs L342212 46 lbs L402212 52 lbs L4622...

Страница 7: ...he rough in plate shipped with the liner to determine framing location 3 After wall surface is finished secure the rough in plate to the wall surface NOTE If additional mounting holes are required for adequate liner support drill additional mounting holes in rough in plate and use these holes to attach liner assembly to wall framing WARNING Framing must be structurally tied together and tied to ce...

Страница 8: ...TION P R O S E R I E S V E N T I L A T I O N H O O D L I N E R S I N S T A L L A T I O N Step 3 Hood Liner Preparation If installing LBLOWER 120INT 805087 see installation for inter nal blower on page 11 IMPORTANT NOTE Wolf recom mends installing the internal blower to the rough in plate assembly prior to installing liner to the wall framing 1 The liner assembly is shipped with the rough in plate ...

Страница 9: ... anchors are required if the screws will not hit the wall stud 9 Step 4 Install the Rough In Plate 1 Use rough in plate assembly to determine stud locations 2 Install 10 x 2 screws through rough in plate into wall framing 3 If additional mounting holes are required for adequate liner support drill additional mounting holes in rough in plate and use these holes to attach rough in plate assembly to ...

Страница 10: ...te wire to power supply white wire and green wire to green wire or bare wire 5 Place all wiring connections inside junction box and re install on rough in plate Make sure that wires are secure and that no wires are pinched between cover and box Wiring Diagram Refer to the wiring diagram packaged with the liner for more information Step 7 Install Hood Liner Filters and Drip Cups 1 Remove all packag...

Страница 11: ...plate install the liner rough in plate to the wall Be sure to secure power cord s so as not to damage or pinch while installing liner shell I N T E R N A L B L O W E R IMPORTANT NOTE Before turning the power on make sure the blower is in the OFF position Use wire con nectors or wire nuts approved by UL or C UL Refer to installation instruc tions provided with each blower to verify wall or roof cut...

Страница 12: ...ps on liner interior to keep excess power cord away from moving parts 5 Re install wiring box cover and screws Make sure all wires are secure and that no wires are pinched between cover and box STEP 2 Connect Remote Blower NOTE Always refer to all blower installation instructions provided with the blower for additional mounting and wiring instructions 1 Remove cover from wiring box inside of liner...

Страница 13: ...K DF 42 W x 38 H backsplash for 42 wall hoods 48BAK DF 48 W x 38 H backsplash for 48 wall hoods 54BAK DF 54 W x 38 H backsplash for 54 wall hoods 60BAK DF 60 W x 38 H backsplash for 60 wall hoods 66BAK DF 66 W x 38 H backsplash for 66 wall hoods Remote Blowers CTBLOWER 60REM 801640 600 CFM remote blower for ventilation hood liners except Model L282212I CTBLOWER 90REM 801641 900 CFM remote blower f...

Страница 14: ...authorized Wolf Factory Authorized Service Center Do not attempt to repair the ventilation hood liner yourself Wolf is not responsible for service required to correct a faulty installation To obtain the name and number of a Wolf Factory Authorized Service Center call Wolf Customer Service at 800 332 9513 or check our website www wolfappliance com When calling for service you will need the ventilat...

Страница 15: ...of Sub Zero Freezer Company Inc Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance Company LLC an affiliate of Sub Zero Freezer Company Inc Wolf Appliance Company LLC all rights reserved ...

Страница 16: ...WOLF APPLIANCE COMPANY LLC P O Box 44848 Madison WI 53744 800 332 9513 www wolfappliance com 805049 REV C 9 03 ...

Отзывы: