NOTE: In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39067 (04-07)
MODEL: IRG
INSTANT RECOVERY GRIDDLE
INSTALLATION REQUIREMENTS:
1. A gas pressure regulator sized for this unit is included.
Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.
2. Gas line connecting to appliance must be ¾" diameter or
larger. If flexible connectors are used, the inside diameter
must be the same as the ¾" iron pipe.
3. 115 volt, 50/60 Hz, 1 phase control circuit. ½ amp draw.
Provided with 6' power cord with 3 prong plug.
4. An adequate ventilation system is required for commer-
cial cooking equipment. Information may be obtained
by writing to the National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org.
When writing, refer to NFPA No. 96.
5. These units are manufactured for installation in accordance
with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American
Gas Association, Accredited Standards Committee Z223
@ 400N. Capital St. NW, Washington, DC 20001, or the
Secretary Standards Council, NFPA, 1 Batterymarch Park,
Quincy, MA 02169-7471.
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or
exhaust system equipped with a damper or with a power
means of exhaust shall comply with 248 CMR.
6. Clearances:
Combustible
Non-Combustible
Rear
6"
0"
Sides
6"
0"
115 volt, 50/60 Hz, 1 phase control circuit. ½ amp draw. Provided with 6' power cord with 3 prong plug.
Griddle
Model
Griddle
Surface
Overall
No. of
Approx. Ship Wt. (lbs./kg)
No.
BTU/hr.
Width
Depth
Width
Controls
Counter
Floor
IRG36
60,000
36"
x
24"
36"
3
475/214
545/245
IRG48
80,000
48"
x
24"
48"
4
575/259
665/299
IRG60
100,000
60"
x
24"
60"
5
666/300
855/385
IRG72
120,000
72"
x
24"
72"
6
855/385
1080/486
See equipment stand spec sheets for dimensions.