Planning Information
Integrated Gas Multi-Function Cooktop
M O D E L I M 1 5 / S
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, cut-out dimensions and
installation specifics.
Wolf recommends using 33" (838) wide
cabinets for installation of two 15" (381)
modules side by side. An 18" (457) wide
cabinet is recommended for installation of a
single 15" (381) cooktop or module.
IMPORTANT NOTE:
Review specific installation
instructions for product to product capabilities
When multiple cooktops or modules are
installed side by side, refer to the countertop
cut-out dimensions on page 6.
A Wolf downdraft system, Cooktop or
Pro ventilation hood is recommended. When
installing a ventilation hood, refer to the specific
requirements of the hood for the minimum
dimension to countertop. Also refer to
Ventilation Recommendations in the Cooktop
Ventilation or Pro Ventilation sections of our
website, wolfappliance.com.
The Wolf gas multi-function cooktop
requires a separate 120 V, 60 Hz power supply.
The service should have its own 15 amp circuit
breaker, and a grounded 3-prong receptacle
should be located within the reach of the 6'
(1.8 m) power cord. Locate electrical within
the shaded area shown in the Installation
illustration on page 4.
IMPORTANT NOTE:
A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
For the gas multi-function cooktop, the gas
service may be supplied through the floor. Refer
to the Installation illustration on page 4 for
placement of electrical and gas supply.
The Wolf gas multi-function cooktop is
designed to operate on natural gas at 5"
(12.5 mb) WC (water column) pressure or LP
(propane) gas at 10" (25 mb) WC pressure. The
minimum line pressure for natural gas is 7"
(17.5 mb) WC and 11" (27.4 mb) WC for LP
gas. The maximum gas supply pressure to the
regulator should never exceed 14" (34.9 mb)
WC; .5 psi (3.5 kPa). The cooktop is supplied
with a
1
/
2
" NPT male gas connection at the
right rear bottom corner of the cooktop. The
male connector exits the unit straight down and
you are supplied with a regulator with two
female connectors.
Wolf gas cooktops using natural gas
function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas installa-
tions from 8,000' (2438 m) to 10,000' (3048 m)
need the high altitude conversion kit. LP gas
installations will operate up to 10,000' (3048 m)
without adjustment.
You must follow all National Electrical Code
and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.
This cooktop is intended for indoor use only.