Planning Information

Integrated Gas Multi-Function Cooktop

M O D E L   I M 1 5 / S

Dimensions in parentheses are in
millimeters unless otherwise specified.

5

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, cut-out dimensions and
installation specifics.

Wolf recommends using 33" (838) wide

cabinets for installation of two 15" (381)
modules side by side. An 18" (457) wide
cabinet is recommended for installation of a
single 15" (381) cooktop or module. 

IMPORTANT NOTE:

Review specific installation

instructions for product to product capabilities

When multiple cooktops or modules are

installed side by side, refer to the countertop
cut-out dimensions on page 6.

A Wolf downdraft system, Cooktop or

Pro ventilation hood is recommended. When
installing a ventilation hood, refer to the specific
requirements of the hood for the minimum
dimension to countertop. Also refer to
Ventilation  Recommendations in the Cooktop
Ventilation or Pro Ventilation sections of our
website, wolfappliance.com.

The Wolf gas multi-function cooktop

requires a separate 120 V, 60 Hz power supply.
The service should have its own 15 amp circuit
breaker, and a grounded 3-prong receptacle
should be located within the reach of the 6'
(1.8 m) power cord. Locate electrical within
the shaded area shown in the Installation
illustration on page 4. 

IMPORTANT NOTE: 

A ground fault circuit

interrupter (GFCI) is not recommended and may
cause interruption of operation.

For the gas multi-function cooktop, the gas

service may be supplied through the floor. Refer
to the Installation illustration on page 4 for
placement of electrical and gas supply.

The Wolf gas multi-function cooktop is

designed to operate on natural gas at 5"
(12.5 mb) WC (water column) pressure or LP
(propane) gas at 10" (25 mb) WC pressure. The
minimum line pressure for natural gas is 7"
(17.5 mb) WC and 11" (27.4 mb) WC for LP
gas. The maximum gas supply pressure to the
regulator should never exceed 14" (34.9 mb)
WC; .5 psi (3.5 kPa). The cooktop is supplied
with a 

1

/

2

" NPT male gas connection at the

right rear bottom corner of the cooktop. The
male connector exits the unit straight down and
you are supplied with a regulator with two
female connectors.

Wolf gas cooktops using natural gas

function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas installa-
tions from 8,000' (2438 m) to 10,000' (3048 m)
need the high altitude conversion kit. LP gas
installations will operate up to 10,000' (3048 m)
without adjustment.

You must follow all National Electrical Code

and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.

Refer to the installation instructions

shipped with each Wolf product for detailed
specifications.

This cooktop is intended for indoor use only.

Содержание IM15

Страница 1: ...he wok then dispersing it outward for precisely controlled cooking The larger grate will handle your wok perfectly but also accommodate even your largest stockpots Dutch ovens and the like The powerful burner exceeds 18 000 Btu hr 5 3 kW Let Wolf the corporate companion and kitchen soul mate of Sub Zero fuel your passion for cooking and kitchen design The Wolf Model IM15 S 15 381 gas multi functio...

Страница 2: ...tainless steel finish High output 18 000 Btu hr 5 3 kW dual stacked sealed burner Automatic electronic reignition system Illuminated control panel Individual spark ignition system Two interchangeable cast iron burner grates with matte porcelain finish wok grate and low profile continuous grate Deep drawn burner pan CSA certified for US and Canada Two and five year residential warranty exclusions a...

Страница 3: ...14 kg Special Note Cooktop can be installed in combination with other cooktops or modules Specifications are subject to change without notice T R I M F I N I S H Classic Stainless Steel IM15 S V E N T I L A T I O N O P T I O N S 30 762 Cooktop or Pro wall hood or liner 30 762 or 45 1143 downdraft ventilation system 36 914 Cooktop or Pro island hood For additional information refer to the Wolf Cook...

Страница 4: ...14 356 COOKTOP CUT OUT WIDTH 14 356 COOKTOP CUT OUT WIDTH 33 838 RECOMMENDED CABINET WIDTH 18 457 NOTE Application shown allows for installation of two 15 381 modules side by side with 33 838 recommended cabinet width 18 457 recommended cabinet width for installation of single 15 381 cooktop or module Minimum clearance from both side edges of cooktop cut out to combustible materials up to 18 457 a...

Страница 5: ...the shaded area shown in the Installation illustration on page 4 IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation For the gas multi function cooktop the gas service may be supplied through the floor Refer to the Installation illustration on page 4 for placement of electrical and gas supply The Wolf gas multi function cooktop is desig...

Страница 6: ...ation of multiple cooktops IMPORTANT NOTE Refer to the pages for each specific integrated module for installation limitations IMPORTANT NOTE Where multiple cooktops and or modules are installed side by side each unit must have its own separate recommended electrical circuit When multiple gas cooktops and or modules are installed next to one another they can receive their gas supply from a common l...

Отзывы: