Fryer Module Specifications
4
1
/
2
"
(13)
SIDES
1"
(25)
FRONT / BACK
7
1
/
2
"
(191)
6"
(152)
DRAIN
OUTLET
21"
(533)
15"
(381)
Overall Dimensions
FRYER MODULE
Installation Specifications
IMPORTANT NOTE:
Installation of the Wolf electric fryer
module must meet minimum clearance requirements
shown in the installation illustration on page 6.
The fryer module is designed to fit a standard 24" (610)
deep base cabinet with 25" (635) deep countertop. Before
making the countertop cut-out, verify that the module will
clear the side walls of the base cabinet below.
It is recommended that you use a Wolf cooktop ventilation
hood, pro hood or hood liner with the fryer module. Refer
to the Wolf design guide.
IMPORTANT NOTE:
Wolf does not recommend the use of
downdraft ventilation with the fryer module.
MANUAL DRAIN OUTLET
IMPORTANT NOTE:
The fryer module must be installed in
a base cabinet that allows access to the manual drain
valve for draining the oil. A heat-resistant bucket must be
positioned under the drain outlet to accept the oil. The
bucket must have a minimum 2 gallon (7.6 L) capacity.
Refer to the installation illustration on page 6 for location
of the manual drain outlet.
Failure to locate the fryer module without the proper
clearances will result in a fire hazard.
The fryer module is intended for indoor use.