INDUCTION COOKTOP ERROR CODES
INDUCTION ERROR CODES
Error
Code
Error
Component
Error Description
Service Instruction
E 00
Overvoltage
Generator
Over voltage detection from the
induction generator.
1
Check voltage supply.
2
Replace induction generator.
E 01
Left key error
Left secondary
Key error on the left secondary
1
Reseat wire harnesses.
2
Replace the left secondary control
board.
E 02
Right key error
Right secondary
Key error on the right secondary 1 Reseat wire harnesses.
2
Replace the right secondary control
board.
E 03
Center key error
Primary
Key error on the primary
1
Reseat wire harnesses.
2
Replace the primary control board.
E 04
Data flash error
All components
Not a shown error. A cyclic reset
of the controller
1
Cycle the unit electrical supply.
2
Replace the primary and secondary
control boards.
3
Replace the induction generator.
E 05
LIN communication error
Primary
No response from the generator.
Cable or generator issue.
1
Reseat the wire harnesses.
2
Replace the induction generator.
E 06
Controller options error
Not currently used
E 07
TC temperature too high
Primary
Primary is too hot.
1
Check airflow for blockage.
2
Replace primary control board.
E 08
Invalid generator
configuration
Generator
1
Cycle the unit electrical supply.
2
Replace the induction generator.
E 09
Coil assembly 1 temperature
too high
Generator
1
Replace the coil assembly.
2
Replace the induction generator.
E 10
Coil assembly 2 temperature
too high
Generator
1
Replace the coil assembly.
2
Replace the induction generator.
E 11
Coil assembly 3 temperature
too high
Generator
1
Replace the coil assembly.
2
Replace the induction generator.
E 12
Coil assembly 4 temperature
too high
Generator
1
Replace the coil assembly.
2
Replace the induction generator.
E 13
Coil assembly 5 temperature
too high
Generator
1
Replace the coil assembly.
2
Replace the induction generator.
E 14
Configuration implausible
Generator
•
0x13 = CRC error of
configuration data.
•
0x30 = Configuration values
implausible.
1
Cycle the unit electrical supply.
2
Replace the induction generator.
E 15
Power supply error on
generator
Generator
Generator voltage too low.
1
Check voltage supply.
2
Replace induction generator.
30" and 36" Induction Range
Troubleshooting
service.subzero.com
829191 REVA