![Wolf DD30I Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/wolf/dd30i/dd30i_planning-information_992191009.webp)
9
Dimensions in parentheses are in
millimeters unless otherwise specified.
Planning Information
30"
(762)
Downdraft Ventilation System
M O D E L S D D 3 0 I A N D D D 3 0 R
Downdraft Ventilation Systems
Blower Description
Blower Number
Downdraft Models
500 CFM Internal
Included with (I) Models
DD30I / DD36I / DD45I
1100 CFM In-Line
BLOWER-110IL (808332)
DD30R / DD36R / DD45R
900 CFM Remote
BLOWER-90REM (801641)
DD30R / DD36R / DD45R
1200 CFM Remote
BLOWER-120REM (801642)
DD30R / DD36R / DD45R
1500 CFM Remote
BLOWER-150REM (804701)
DD30R / DD36R / DD45R
Adjustable discharge. 3
1
/
4
" (83) x 10" (254) duct for internal blower, no transition required. 3
1
/
4
" (83) x 14" (356)
duct for in-line and remote blowers. TRANS-14-10 required for remote blowers.
C O O K T O P V E N T I L A T I O N B L O W E R O P T I O N S
Downdraft Ventilation Systems
Cooktop
DD30
DD36
DD45
Model CT15I
215*
150*
Model CT30I
500
350
Model CT36I
500
Model CT15E
215*
150*
Model CT30E
500
350
Model CT36E
500
Model CT15G
215*
150*
Model CT30G
500
350
Model CT36G
500
Model IM15
215*
150*
Model SRT304
600
Model SRT366
900
*Use these recommendations to determine total CFM when installing multiple cooktops or modules.
Minimum CFM requirements for Wolf cooktops. CFM recommendations are based on total Btu/hr output. Additional
CFM may be required for long duct runs.
C O O K T O P V E N T I L A T I O N C F M R E C O M M E N D A T I O N S