Planning Information

New 36"

(914)

Unframed Induction Cooktop

M O D E L   C T 3 6 I U

Dimensions in parentheses are in
millimeters unless otherwise specified.

5

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, cut-out dimensions and
installation specifics.

Wolf recommends using 39" (991) cabinets

with the 36" (914) unframed induction cooktop.

Clearance is required for the conduit located

on the bottom of the cooktop in the right rear
corner.

IMPORTANT NOTE:

A minimum height clear-

ance of 6" (152) is required between the coun-
tertop and any combustible surface directly
below the cooktop. This includes upper edges
of drawers located directly below unit. If a shelf
is installed below the unit, a 1" (25) gap at the
rear of the cabinet shelf is necessary to allow
for proper ventilation. Failure to do so could
result in decreased performance or product
damage.

A Wolf Cooktop or Pro ventilation hood is

recommended. When installing a ventilation
hood, refer to the specific requirements of the
hood for the minimum dimension to countertop.
Also refer to the ventilation recommendation
charts in the cooktop or Pro ventilation sections
of our website, wolfappliance.com.

The Wolf 36" (914) unframed induction

cooktop requires a separate, grounded 3-wire
240/208 V AC, 50/60 Hz, 50 amp service with
its own circuit breaker. It has a 4' (1.2 m)
flexible 3-wire conduit for connection at the
electrical supply. Locate electrical within the
shaded area shown in the Installation illustra-
tion on page 4.

A Wolf built-in single oven may be installed

below this cooktop. For this installation, the
electrical supply for the cooktop should be
installed in the adjacent cabinet. Be aware of
the depth of the cooktop when planning for this
installation.

IMPORTANT NOTE:

When a built-in oven is

installed below the cooktop, unless you are
using cabinets deeper than 24" (610), it is
recommended that the electrical supply be
placed in an adjacent cabinet within reach of
the conduit.

IMPORTANT NOTE: 

Wolf unframed induction

cooktops are designed and agency approved for
installation with Wolf built-in ovens only.

You must follow all National Electrical Code

regulations. In addition, be aware of local codes
and ordinances when installing your service.

Refer to the installation instructions

shipped with each Wolf product for detailed
specifications.

This cooktop is intended for indoor use only.

Содержание CT36IU

Страница 1: ...k to the bottom of the vessel in order to function Induction cooking is so efficient that it out performs gas and electric cooktops There is no wasted heat because energy is supplied directly to the cooking vessel so nearly 90 percent of the energy gets used to cook You can keep sauces and chocolates melted at 50 watts of power or with the touch of a finger activate the Hi Power boost feature and ...

Страница 2: ...induction compatible pan on the cooktop surface Hi Power mode boosts power on 1800 W elements by diverting power from adjacent element 4000 W element does not divert power from adjacent element for boost Temperature limiter to ensure that safe operating temperature of ceramic glass is never exceeded Illuminated touch controls with graduated control lighting and adjustable sound frequency and volum...

Страница 3: ...78 Minimum Height Clearance 5 127 Cooktop Cut Out Width 343 8 873 Cooktop Cut Out Depth 193 8 492 Electrical Supply Requirements 240 208 V AC 50 60 Hz 50 amp circuit Conduit 4 ft 1 2 m flexible 3 wire Electrical Rating 10 2 kW at 240 V 8 9 kW at 208 V Shipping Weight 70 lbs 32 kg Minimum 61 2 165 clearance is required between countertop and any combustible surface directly below the cooktop Specif...

Страница 4: ...LUSH MOUNT INSTALLATION ONLY 343 8 873 COOKTOP CUT OUT WIDTH 15 16 33 RADIUS FRONT OF COUNTERTOP 27 16 62 193 8 492 COOKTOP CUT OUT DEPTH 19 16 40 211 8 537 RECESSED AREA FOR FLUSH MOUNT INSTALLATION ONLY 7 16 11 RADIUS Minimum dimension but may be exceeded by up to 1 8 3 RECESSED AREA FOR FLUSH MOUNT INSTALLATION ONLY 5 16 8 7 8 22 max COUNTERTOP PROFILE SEE COUNTERTOP CUT OUT BELOW 13 max 330 24...

Страница 5: ...ilation recommendation charts in the cooktop or Pro ventilation sections of our website wolfappliance com The Wolf 36 914 unframed induction cooktop requires a separate grounded 3 wire 240 208 V AC 50 60 Hz 50 amp service with its own circuit breaker It has a 4 1 2 m flexible 3 wire conduit for connection at the electrical supply Locate electrical within the shaded area shown in the Installation i...

Отзывы: